The precision of propex Pixi with different instruments and coronal preflaring procedures

Detalhes bibliográficos
Autor(a) principal: Ferreira, Ines
Data de Publicação: 2019
Outros Autores: Braga, A. C., Pina-Vaz, Irene
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/70511
Resumo: Objective:This study aimed to evaluate the influence of the instrument regarding the apical fit and type of the alloy and coronal preflaring procedures in the accuracy of Propex Pixi.Methods: A total of 40 extracted human single-rooted permanent teeth with apical diameters of 200 mu m were selected. A #10 K-file was inserted in the root canal until its end could be observed by a dental microscope to obtain the actual working length (WL). Electronic measurements were performed using Propex Pixi to the root apex ("0.0"). Different file alloys (stainless steel [SS] and nickel titanium [NiTi]) and sizes (#10, #15, and #20) were used before and after coronal flaring. Statistical analysis was performed by a factorial analysis of variance (P <= 0.05).Results: Results showed that the measurements of electronic length (EL) were closer to the actual working length (WL) after coronal flaring (P<0.05). A significant intraclass correlation was observed between EL and WL. In addition, results showed no significant differences between files with different sizes or alloys.Conclusion: Under the conditions of this study, Propex Pixi demonstrated adequate precision. Its accuracy was enhanced by coronal preflaring procedures regardless of the instrument type used (SS or NiTi) and the apical fit.
id RCAP_63582d1c2358f609ba9710c843d1127c
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/70511
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling The precision of propex Pixi with different instruments and coronal preflaring proceduresDental instrumentsendodonticsodontometryScience & TechnologyObjective:This study aimed to evaluate the influence of the instrument regarding the apical fit and type of the alloy and coronal preflaring procedures in the accuracy of Propex Pixi.Methods: A total of 40 extracted human single-rooted permanent teeth with apical diameters of 200 mu m were selected. A #10 K-file was inserted in the root canal until its end could be observed by a dental microscope to obtain the actual working length (WL). Electronic measurements were performed using Propex Pixi to the root apex ("0.0"). Different file alloys (stainless steel [SS] and nickel titanium [NiTi]) and sizes (#10, #15, and #20) were used before and after coronal flaring. Statistical analysis was performed by a factorial analysis of variance (P <= 0.05).Results: Results showed that the measurements of electronic length (EL) were closer to the actual working length (WL) after coronal flaring (P<0.05). A significant intraclass correlation was observed between EL and WL. In addition, results showed no significant differences between files with different sizes or alloys.Conclusion: Under the conditions of this study, Propex Pixi demonstrated adequate precision. Its accuracy was enhanced by coronal preflaring procedures regardless of the instrument type used (SS or NiTi) and the apical fit.- (undefined)Kare PublishingUniversidade do MinhoFerreira, InesBraga, A. C.Pina-Vaz, Irene20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/70511engFerreira, I., Braga, A. C., & Pina-vaz, I. (2019). The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures. European Endodontic Journal, 4(2), 75-79. doi: 10.14744/eej.2019.527242548-083910.14744/eej.2019.52724https://eurendodj.com/jvi.aspx?un=EEJ-52724info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:12:35Zoai:repositorium.sdum.uminho.pt:1822/70511Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:04:31.953138Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv The precision of propex Pixi with different instruments and coronal preflaring procedures
title The precision of propex Pixi with different instruments and coronal preflaring procedures
spellingShingle The precision of propex Pixi with different instruments and coronal preflaring procedures
Ferreira, Ines
Dental instruments
endodontics
odontometry
Science & Technology
title_short The precision of propex Pixi with different instruments and coronal preflaring procedures
title_full The precision of propex Pixi with different instruments and coronal preflaring procedures
title_fullStr The precision of propex Pixi with different instruments and coronal preflaring procedures
title_full_unstemmed The precision of propex Pixi with different instruments and coronal preflaring procedures
title_sort The precision of propex Pixi with different instruments and coronal preflaring procedures
author Ferreira, Ines
author_facet Ferreira, Ines
Braga, A. C.
Pina-Vaz, Irene
author_role author
author2 Braga, A. C.
Pina-Vaz, Irene
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Ferreira, Ines
Braga, A. C.
Pina-Vaz, Irene
dc.subject.por.fl_str_mv Dental instruments
endodontics
odontometry
Science & Technology
topic Dental instruments
endodontics
odontometry
Science & Technology
description Objective:This study aimed to evaluate the influence of the instrument regarding the apical fit and type of the alloy and coronal preflaring procedures in the accuracy of Propex Pixi.Methods: A total of 40 extracted human single-rooted permanent teeth with apical diameters of 200 mu m were selected. A #10 K-file was inserted in the root canal until its end could be observed by a dental microscope to obtain the actual working length (WL). Electronic measurements were performed using Propex Pixi to the root apex ("0.0"). Different file alloys (stainless steel [SS] and nickel titanium [NiTi]) and sizes (#10, #15, and #20) were used before and after coronal flaring. Statistical analysis was performed by a factorial analysis of variance (P <= 0.05).Results: Results showed that the measurements of electronic length (EL) were closer to the actual working length (WL) after coronal flaring (P<0.05). A significant intraclass correlation was observed between EL and WL. In addition, results showed no significant differences between files with different sizes or alloys.Conclusion: Under the conditions of this study, Propex Pixi demonstrated adequate precision. Its accuracy was enhanced by coronal preflaring procedures regardless of the instrument type used (SS or NiTi) and the apical fit.
publishDate 2019
dc.date.none.fl_str_mv 2019
2019-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/70511
url http://hdl.handle.net/1822/70511
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Ferreira, I., Braga, A. C., & Pina-vaz, I. (2019). The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures. European Endodontic Journal, 4(2), 75-79. doi: 10.14744/eej.2019.52724
2548-0839
10.14744/eej.2019.52724
https://eurendodj.com/jvi.aspx?un=EEJ-52724
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Kare Publishing
publisher.none.fl_str_mv Kare Publishing
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132454768869376