The precision of propex Pixi with different instruments and coronal preflaring procedures
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/70511 |
Resumo: | Objective:This study aimed to evaluate the influence of the instrument regarding the apical fit and type of the alloy and coronal preflaring procedures in the accuracy of Propex Pixi.Methods: A total of 40 extracted human single-rooted permanent teeth with apical diameters of 200 mu m were selected. A #10 K-file was inserted in the root canal until its end could be observed by a dental microscope to obtain the actual working length (WL). Electronic measurements were performed using Propex Pixi to the root apex ("0.0"). Different file alloys (stainless steel [SS] and nickel titanium [NiTi]) and sizes (#10, #15, and #20) were used before and after coronal flaring. Statistical analysis was performed by a factorial analysis of variance (P <= 0.05).Results: Results showed that the measurements of electronic length (EL) were closer to the actual working length (WL) after coronal flaring (P<0.05). A significant intraclass correlation was observed between EL and WL. In addition, results showed no significant differences between files with different sizes or alloys.Conclusion: Under the conditions of this study, Propex Pixi demonstrated adequate precision. Its accuracy was enhanced by coronal preflaring procedures regardless of the instrument type used (SS or NiTi) and the apical fit. |
id |
RCAP_63582d1c2358f609ba9710c843d1127c |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/70511 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
The precision of propex Pixi with different instruments and coronal preflaring proceduresDental instrumentsendodonticsodontometryScience & TechnologyObjective:This study aimed to evaluate the influence of the instrument regarding the apical fit and type of the alloy and coronal preflaring procedures in the accuracy of Propex Pixi.Methods: A total of 40 extracted human single-rooted permanent teeth with apical diameters of 200 mu m were selected. A #10 K-file was inserted in the root canal until its end could be observed by a dental microscope to obtain the actual working length (WL). Electronic measurements were performed using Propex Pixi to the root apex ("0.0"). Different file alloys (stainless steel [SS] and nickel titanium [NiTi]) and sizes (#10, #15, and #20) were used before and after coronal flaring. Statistical analysis was performed by a factorial analysis of variance (P <= 0.05).Results: Results showed that the measurements of electronic length (EL) were closer to the actual working length (WL) after coronal flaring (P<0.05). A significant intraclass correlation was observed between EL and WL. In addition, results showed no significant differences between files with different sizes or alloys.Conclusion: Under the conditions of this study, Propex Pixi demonstrated adequate precision. Its accuracy was enhanced by coronal preflaring procedures regardless of the instrument type used (SS or NiTi) and the apical fit.- (undefined)Kare PublishingUniversidade do MinhoFerreira, InesBraga, A. C.Pina-Vaz, Irene20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/70511engFerreira, I., Braga, A. C., & Pina-vaz, I. (2019). The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures. European Endodontic Journal, 4(2), 75-79. doi: 10.14744/eej.2019.527242548-083910.14744/eej.2019.52724https://eurendodj.com/jvi.aspx?un=EEJ-52724info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:12:35Zoai:repositorium.sdum.uminho.pt:1822/70511Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:04:31.953138Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
The precision of propex Pixi with different instruments and coronal preflaring procedures |
title |
The precision of propex Pixi with different instruments and coronal preflaring procedures |
spellingShingle |
The precision of propex Pixi with different instruments and coronal preflaring procedures Ferreira, Ines Dental instruments endodontics odontometry Science & Technology |
title_short |
The precision of propex Pixi with different instruments and coronal preflaring procedures |
title_full |
The precision of propex Pixi with different instruments and coronal preflaring procedures |
title_fullStr |
The precision of propex Pixi with different instruments and coronal preflaring procedures |
title_full_unstemmed |
The precision of propex Pixi with different instruments and coronal preflaring procedures |
title_sort |
The precision of propex Pixi with different instruments and coronal preflaring procedures |
author |
Ferreira, Ines |
author_facet |
Ferreira, Ines Braga, A. C. Pina-Vaz, Irene |
author_role |
author |
author2 |
Braga, A. C. Pina-Vaz, Irene |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Ferreira, Ines Braga, A. C. Pina-Vaz, Irene |
dc.subject.por.fl_str_mv |
Dental instruments endodontics odontometry Science & Technology |
topic |
Dental instruments endodontics odontometry Science & Technology |
description |
Objective:This study aimed to evaluate the influence of the instrument regarding the apical fit and type of the alloy and coronal preflaring procedures in the accuracy of Propex Pixi.Methods: A total of 40 extracted human single-rooted permanent teeth with apical diameters of 200 mu m were selected. A #10 K-file was inserted in the root canal until its end could be observed by a dental microscope to obtain the actual working length (WL). Electronic measurements were performed using Propex Pixi to the root apex ("0.0"). Different file alloys (stainless steel [SS] and nickel titanium [NiTi]) and sizes (#10, #15, and #20) were used before and after coronal flaring. Statistical analysis was performed by a factorial analysis of variance (P <= 0.05).Results: Results showed that the measurements of electronic length (EL) were closer to the actual working length (WL) after coronal flaring (P<0.05). A significant intraclass correlation was observed between EL and WL. In addition, results showed no significant differences between files with different sizes or alloys.Conclusion: Under the conditions of this study, Propex Pixi demonstrated adequate precision. Its accuracy was enhanced by coronal preflaring procedures regardless of the instrument type used (SS or NiTi) and the apical fit. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2019-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/70511 |
url |
http://hdl.handle.net/1822/70511 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Ferreira, I., Braga, A. C., & Pina-vaz, I. (2019). The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures. European Endodontic Journal, 4(2), 75-79. doi: 10.14744/eej.2019.52724 2548-0839 10.14744/eej.2019.52724 https://eurendodj.com/jvi.aspx?un=EEJ-52724 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Kare Publishing |
publisher.none.fl_str_mv |
Kare Publishing |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132454768869376 |