Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection

Detalhes bibliográficos
Autor(a) principal: Oliveira, T. V. de
Data de Publicação: 2015
Outros Autores: Soares, N. de F. F., Carvalho, Carla A. O. C. M., Coimbra, J. S. dos R., Andrade, N. J. de, Azeredo, Joana, Medeiros, E. A. A., Freitas, P. P.
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/36833
Resumo: Polydiacetylene polymer (PDA) has been intensively studied because of its properties as colour change from blue to red and change from non-fluorescent to fluorescent form due to an external stimulus that lead to a reorientation of the PDA within the organized structure. External stimulus could be temperature, pH, solvent influence, bacteria presence, mechanical stresses and others (Oliveira et al., 2012). Pires et al. (2010) support the hypothesis that such phenomena occurred due to conformational changes associated with the functional group rotation around the simple carbon-carbon bond present in PDA chains. When the backbones of PDA conjugated polymer chains are perturbed, the delocalized π-network induces changes in electronic absorption and emission properties (Huo et al., 1999). For a particular colour change, it is possible to incorporate a compound in the polydiacetylene carboxyl groups that will work as a specific receptor for the bacteria detection. This technology can be used for the detection of pathogens and thus is important to avoid food contamination once the standard technology demands long time and people trained. The selection of the receptor used in the PDA is the first critical step to develop a biosensor with improved selectivity, selectivity and stability. For this reason, the aim of this study was to make a comparative study between two recognition molecules: phage PVP-S1 (Santos et al., 2011) and a monoclonal antibody in the PDA sensor for the detection of Salmonella. Antibodies lack specificity, poor separation efficiency and sensitivity. Phages are extremely specific, withstand harsh environments, are economically and easily produced, show high stability during storage and thus present potential for bacterial detection. Overall the selection of the recognition molecule that show the best features is important to develop a simple and rapid sensor for the industry and consumer’s life. The specificity of the sensor was proven by using Staphylococus aures and Escherichia coli as gram-positive and gram-negative controls, respectively.
id RCAP_64e46318f26fb3ef791f5a3873289433
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/36833
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detectionPolydiacetylene vesiclesMonoclonal antibodySalmonella detectionPhagesSpecificitySensitivityCiências Naturais::Ciências BiológicasPolydiacetylene polymer (PDA) has been intensively studied because of its properties as colour change from blue to red and change from non-fluorescent to fluorescent form due to an external stimulus that lead to a reorientation of the PDA within the organized structure. External stimulus could be temperature, pH, solvent influence, bacteria presence, mechanical stresses and others (Oliveira et al., 2012). Pires et al. (2010) support the hypothesis that such phenomena occurred due to conformational changes associated with the functional group rotation around the simple carbon-carbon bond present in PDA chains. When the backbones of PDA conjugated polymer chains are perturbed, the delocalized π-network induces changes in electronic absorption and emission properties (Huo et al., 1999). For a particular colour change, it is possible to incorporate a compound in the polydiacetylene carboxyl groups that will work as a specific receptor for the bacteria detection. This technology can be used for the detection of pathogens and thus is important to avoid food contamination once the standard technology demands long time and people trained. The selection of the receptor used in the PDA is the first critical step to develop a biosensor with improved selectivity, selectivity and stability. For this reason, the aim of this study was to make a comparative study between two recognition molecules: phage PVP-S1 (Santos et al., 2011) and a monoclonal antibody in the PDA sensor for the detection of Salmonella. Antibodies lack specificity, poor separation efficiency and sensitivity. Phages are extremely specific, withstand harsh environments, are economically and easily produced, show high stability during storage and thus present potential for bacterial detection. Overall the selection of the recognition molecule that show the best features is important to develop a simple and rapid sensor for the industry and consumer’s life. The specificity of the sensor was proven by using Staphylococus aures and Escherichia coli as gram-positive and gram-negative controls, respectively.Universidade do MinhoOliveira, T. V. deSoares, N. de F. F.Carvalho, Carla A. O. C. M.Coimbra, J. S. dos R.Andrade, N. J. deAzeredo, JoanaMedeiros, E. A. A.Freitas, P. P.2015-06-152015-06-15T00:00:00Zconference objectinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/36833engde Oliveira, T. V.; Soares, N. de F. F.; Carvalho, Carla A. O. C. M.; Coimbra, J. S. dos R.; de Andrade, N. J.; Azeredo, Joana; Medeiros, E. A. A.; Freitas, P. P., Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection. NANOTECH FRANCE 2015 - International Nanotech and Nanoscience Conference & Exhibition. Paris, France, June 15-17, 146, 2015.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-05-11T05:26:56Zoai:repositorium.sdum.uminho.pt:1822/36833Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-05-11T05:26:56Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
title Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
spellingShingle Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
Oliveira, T. V. de
Polydiacetylene vesicles
Monoclonal antibody
Salmonella detection
Phages
Specificity
Sensitivity
Ciências Naturais::Ciências Biológicas
title_short Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
title_full Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
title_fullStr Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
title_full_unstemmed Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
title_sort Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection
author Oliveira, T. V. de
author_facet Oliveira, T. V. de
Soares, N. de F. F.
Carvalho, Carla A. O. C. M.
Coimbra, J. S. dos R.
Andrade, N. J. de
Azeredo, Joana
Medeiros, E. A. A.
Freitas, P. P.
author_role author
author2 Soares, N. de F. F.
Carvalho, Carla A. O. C. M.
Coimbra, J. S. dos R.
Andrade, N. J. de
Azeredo, Joana
Medeiros, E. A. A.
Freitas, P. P.
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Oliveira, T. V. de
Soares, N. de F. F.
Carvalho, Carla A. O. C. M.
Coimbra, J. S. dos R.
Andrade, N. J. de
Azeredo, Joana
Medeiros, E. A. A.
Freitas, P. P.
dc.subject.por.fl_str_mv Polydiacetylene vesicles
Monoclonal antibody
Salmonella detection
Phages
Specificity
Sensitivity
Ciências Naturais::Ciências Biológicas
topic Polydiacetylene vesicles
Monoclonal antibody
Salmonella detection
Phages
Specificity
Sensitivity
Ciências Naturais::Ciências Biológicas
description Polydiacetylene polymer (PDA) has been intensively studied because of its properties as colour change from blue to red and change from non-fluorescent to fluorescent form due to an external stimulus that lead to a reorientation of the PDA within the organized structure. External stimulus could be temperature, pH, solvent influence, bacteria presence, mechanical stresses and others (Oliveira et al., 2012). Pires et al. (2010) support the hypothesis that such phenomena occurred due to conformational changes associated with the functional group rotation around the simple carbon-carbon bond present in PDA chains. When the backbones of PDA conjugated polymer chains are perturbed, the delocalized π-network induces changes in electronic absorption and emission properties (Huo et al., 1999). For a particular colour change, it is possible to incorporate a compound in the polydiacetylene carboxyl groups that will work as a specific receptor for the bacteria detection. This technology can be used for the detection of pathogens and thus is important to avoid food contamination once the standard technology demands long time and people trained. The selection of the receptor used in the PDA is the first critical step to develop a biosensor with improved selectivity, selectivity and stability. For this reason, the aim of this study was to make a comparative study between two recognition molecules: phage PVP-S1 (Santos et al., 2011) and a monoclonal antibody in the PDA sensor for the detection of Salmonella. Antibodies lack specificity, poor separation efficiency and sensitivity. Phages are extremely specific, withstand harsh environments, are economically and easily produced, show high stability during storage and thus present potential for bacterial detection. Overall the selection of the recognition molecule that show the best features is important to develop a simple and rapid sensor for the industry and consumer’s life. The specificity of the sensor was proven by using Staphylococus aures and Escherichia coli as gram-positive and gram-negative controls, respectively.
publishDate 2015
dc.date.none.fl_str_mv 2015-06-15
2015-06-15T00:00:00Z
dc.type.driver.fl_str_mv conference object
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/36833
url http://hdl.handle.net/1822/36833
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv de Oliveira, T. V.; Soares, N. de F. F.; Carvalho, Carla A. O. C. M.; Coimbra, J. S. dos R.; de Andrade, N. J.; Azeredo, Joana; Medeiros, E. A. A.; Freitas, P. P., Specificity and sensitivity comparative study between phage PVP-S1 and monoclonal antibody as receptor in polydiacetylene vesicles for Salmonella colorimetric detection. NANOTECH FRANCE 2015 - International Nanotech and Nanoscience Conference & Exhibition. Paris, France, June 15-17, 146, 2015.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv mluisa.alvim@gmail.com
_version_ 1817544624668934144