Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process

Detalhes bibliográficos
Autor(a) principal: Peres, A. M.
Data de Publicação: 2013
Outros Autores: Freitas, P., Dias, Luís G., Sousa, Mara E. B. C., Castro, L. M., Veloso, Ana C. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/27722
Resumo: Chloroanisoles, namely 2,4,6-trichloroanisole, are pointed out as the primary responsible of the development of musty off-flavours in bottled wine, due to their migration from cork stoppers, which results in huge economical losses for wine industry. A prevention step is the detection of these compounds in cork planks before stoppers are produced. Mass spectrometry gas chromatography is the reference method used although it is far beyond economical possibilities of the majority of cork stoppers producers. In this work, a portable cyclic voltammetry approach was used to detect 2,4,6-trichloroanisole extracted from natural cork planks to the aqueous phase during the cork boiling industrial treatment process. Analyses were carried out under ambient conditions, in less than 15 min with a low use of solvent and without any sample pre-treatment. The proposed technique had detection (0.31±0.01 ng/L) and quantification (0.95±0.05 ng/L) limits lower than the human threshold detection level. For blank solutions, without 2,4,6-trichloroanisole addition, a concentration in the order of the quantification limit was estimated (1.0±0.2 ng/L), which confirms the satisfactory performance of the proposed methodology. For aqueous samples from the industrial cork planks boiling procedure, intra-day repeatabilities were lower than 3%, respectively. Also, 2,4,6-trichloroanisole contents in the aqueous samples determined by this novel approach were in good agreement with those obtained by GC-MS (correlation coefficient equal to 0.98), confirming the satisfactory accuracy of the proposed methodology. So, since this novel approach is a fast, low-cost, portable and user-friendly method, it can be an alternative and helpful tool for in-situ industrial applications, allowing accurate detection of releasable 2,4,6-trichloroanisole in an earlier phase of cork stoppers production, which may allow implementing more effective cork treatments to reduce or avoid future 2,4,6-trichloroanisole contaminations of wine.
id RCAP_6567de29af0fff3750c65fd79833f4d9
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/27722
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process2,4,6-trichloroanisoleCorkCyclicvoltammetryStandard addition methodScience & TechnologyChloroanisoles, namely 2,4,6-trichloroanisole, are pointed out as the primary responsible of the development of musty off-flavours in bottled wine, due to their migration from cork stoppers, which results in huge economical losses for wine industry. A prevention step is the detection of these compounds in cork planks before stoppers are produced. Mass spectrometry gas chromatography is the reference method used although it is far beyond economical possibilities of the majority of cork stoppers producers. In this work, a portable cyclic voltammetry approach was used to detect 2,4,6-trichloroanisole extracted from natural cork planks to the aqueous phase during the cork boiling industrial treatment process. Analyses were carried out under ambient conditions, in less than 15 min with a low use of solvent and without any sample pre-treatment. The proposed technique had detection (0.31±0.01 ng/L) and quantification (0.95±0.05 ng/L) limits lower than the human threshold detection level. For blank solutions, without 2,4,6-trichloroanisole addition, a concentration in the order of the quantification limit was estimated (1.0±0.2 ng/L), which confirms the satisfactory performance of the proposed methodology. For aqueous samples from the industrial cork planks boiling procedure, intra-day repeatabilities were lower than 3%, respectively. Also, 2,4,6-trichloroanisole contents in the aqueous samples determined by this novel approach were in good agreement with those obtained by GC-MS (correlation coefficient equal to 0.98), confirming the satisfactory accuracy of the proposed methodology. So, since this novel approach is a fast, low-cost, portable and user-friendly method, it can be an alternative and helpful tool for in-situ industrial applications, allowing accurate detection of releasable 2,4,6-trichloroanisole in an earlier phase of cork stoppers production, which may allow implementing more effective cork treatments to reduce or avoid future 2,4,6-trichloroanisole contaminations of wine.This work was partially supported by project PEst-C/EQB/LA0020/2011, financed by FEDER through COMPETE - Programa Operacional Factores de Competitividade and by FCT - Fundacao para a Ciencia e a Tecnologia (Portugal).ElsevierElsevier BVUniversidade do MinhoPeres, A. M.Freitas, P.Dias, Luís G.Sousa, Mara E. B. C.Castro, L. M.Veloso, Ana C. A.20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/27722eng0039-914010.1016/j.talanta.2013.09.03924209365info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:17:35Zoai:repositorium.sdum.uminho.pt:1822/27722Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:10:15.111823Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
title Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
spellingShingle Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
Peres, A. M.
2,4,6-trichloroanisole
Cork
Cyclicvoltammetry
Standard addition method
Science & Technology
title_short Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
title_full Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
title_fullStr Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
title_full_unstemmed Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
title_sort Cyclic voltammetry : a tool to quantify 2,4,6-trichloroanisole in aqueous samples from cork planks boiling industrial process
author Peres, A. M.
author_facet Peres, A. M.
Freitas, P.
Dias, Luís G.
Sousa, Mara E. B. C.
Castro, L. M.
Veloso, Ana C. A.
author_role author
author2 Freitas, P.
Dias, Luís G.
Sousa, Mara E. B. C.
Castro, L. M.
Veloso, Ana C. A.
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Peres, A. M.
Freitas, P.
Dias, Luís G.
Sousa, Mara E. B. C.
Castro, L. M.
Veloso, Ana C. A.
dc.subject.por.fl_str_mv 2,4,6-trichloroanisole
Cork
Cyclicvoltammetry
Standard addition method
Science & Technology
topic 2,4,6-trichloroanisole
Cork
Cyclicvoltammetry
Standard addition method
Science & Technology
description Chloroanisoles, namely 2,4,6-trichloroanisole, are pointed out as the primary responsible of the development of musty off-flavours in bottled wine, due to their migration from cork stoppers, which results in huge economical losses for wine industry. A prevention step is the detection of these compounds in cork planks before stoppers are produced. Mass spectrometry gas chromatography is the reference method used although it is far beyond economical possibilities of the majority of cork stoppers producers. In this work, a portable cyclic voltammetry approach was used to detect 2,4,6-trichloroanisole extracted from natural cork planks to the aqueous phase during the cork boiling industrial treatment process. Analyses were carried out under ambient conditions, in less than 15 min with a low use of solvent and without any sample pre-treatment. The proposed technique had detection (0.31±0.01 ng/L) and quantification (0.95±0.05 ng/L) limits lower than the human threshold detection level. For blank solutions, without 2,4,6-trichloroanisole addition, a concentration in the order of the quantification limit was estimated (1.0±0.2 ng/L), which confirms the satisfactory performance of the proposed methodology. For aqueous samples from the industrial cork planks boiling procedure, intra-day repeatabilities were lower than 3%, respectively. Also, 2,4,6-trichloroanisole contents in the aqueous samples determined by this novel approach were in good agreement with those obtained by GC-MS (correlation coefficient equal to 0.98), confirming the satisfactory accuracy of the proposed methodology. So, since this novel approach is a fast, low-cost, portable and user-friendly method, it can be an alternative and helpful tool for in-situ industrial applications, allowing accurate detection of releasable 2,4,6-trichloroanisole in an earlier phase of cork stoppers production, which may allow implementing more effective cork treatments to reduce or avoid future 2,4,6-trichloroanisole contaminations of wine.
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/27722
url http://hdl.handle.net/1822/27722
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0039-9140
10.1016/j.talanta.2013.09.039
24209365
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
Elsevier BV
publisher.none.fl_str_mv Elsevier
Elsevier BV
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132530918555648