Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode

Bibliographic Details
Main Author: Barroso, M. Fátima
Publication Date: 2005
Other Authors: Nunes, O. C., Vaz, M. Carmo V. F., Delerue-Matos, Cristina
Format: Article
Language: eng
Source: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Download full: http://hdl.handle.net/10400.22/2947
Summary: A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.
id RCAP_65ad1b329ec40a07cc9ab3621f0c97fb
oai_identifier_str oai:recipp.ipp.pt:10400.22/2947
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrodeHanging mercury drop electrodeSquare-wave voltammetryMolinateBiodegradationA square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.Springer-VerlagRepositório Científico do Instituto Politécnico do PortoBarroso, M. FátimaNunes, O. C.Vaz, M. Carmo V. F.Delerue-Matos, Cristina2013-11-25T15:42:27Z20052005-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/2947eng10.1007/s00216-004-2971-9info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:42:33Zoai:recipp.ipp.pt:10400.22/2947Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:23:58.141054Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
title Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
spellingShingle Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
Barroso, M. Fátima
Hanging mercury drop electrode
Square-wave voltammetry
Molinate
Biodegradation
title_short Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
title_full Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
title_fullStr Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
title_full_unstemmed Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
title_sort Square-wave voltametric method for determination of molinate concentration in a biological process using a hanging mercury drop electrode
author Barroso, M. Fátima
author_facet Barroso, M. Fátima
Nunes, O. C.
Vaz, M. Carmo V. F.
Delerue-Matos, Cristina
author_role author
author2 Nunes, O. C.
Vaz, M. Carmo V. F.
Delerue-Matos, Cristina
author2_role author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico do Porto
dc.contributor.author.fl_str_mv Barroso, M. Fátima
Nunes, O. C.
Vaz, M. Carmo V. F.
Delerue-Matos, Cristina
dc.subject.por.fl_str_mv Hanging mercury drop electrode
Square-wave voltammetry
Molinate
Biodegradation
topic Hanging mercury drop electrode
Square-wave voltammetry
Molinate
Biodegradation
description A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.
publishDate 2005
dc.date.none.fl_str_mv 2005
2005-01-01T00:00:00Z
2013-11-25T15:42:27Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/2947
url http://hdl.handle.net/10400.22/2947
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1007/s00216-004-2971-9
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Springer-Verlag
publisher.none.fl_str_mv Springer-Verlag
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131334695714816