Respiratory Pandemic Ventilator: Mechanical development
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/93975 |
Resumo: | Dissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia |
id |
RCAP_7e2dea8d8831848f95e29c2277956726 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/93975 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Respiratory Pandemic Ventilator: Mechanical developmentVentilador Pulmonar pandémico: desenvolvimento mecânicoVentiladorColetorBaixo custoPandémicoAcessívelVentilatorManifoldlow-costPandemicoff-the-shelfDissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e TecnologiaDesde o início pandémico do Corona vírus na China se prevê que a Índia, o segundo maior país do mundo, tome a liderança em termos de número de infectados e mortes causadas pela pandemia.O ano 2020 observou um acréscimo inesperado de 120% na demanda por ventiladores pulmonares invasivos, um equipamento necessário no tratamento de pacientes em estado grave. Com os fabricantes de ventiladores já estabelecidos no mercado, sem capacidade de resposta face ao aumento contínuo gerou-se uma crise mundial derivada da escassez deste precioso equipamento médico.O objectivo principal do trabalho apresentado é desenvolver um ventilador acessível, de baixo custo, cujo o principal componente é o colector das vias aéreas, definido como câmara ou tubagem ramificada em múltiplas aberturas.A intenção é baixar o custo face aos ventiladores de mercado e aumentar a compatibilidade com artigos de fácil compra a meio de uma crise pandémica.A teoria mecânica de ventilação é baseada numa série de canais de ar agregadores de censores, válvulas e electrónica necessária para criar um produto funcional, capaz de fornecer oxigénio e salvar uma vida humana.Topologias paciente-máquina, funcionamento, dimensionamento mecânico, dinâmica de fluidos, métodos de fabrico e ciência dos materiais foram exaustivamente aferidas.Os princípios de ventilação estudados e aprendidos ao longo do desenvolvimento do projecto Atena, o primeiro ventilador Português, foram testados, aprovados e usados como referencias durante todo o trabalho desta dissertação de mestrado.No final, uma nova arquitectura foi concebida capaz de fornecer dados essenciais quanto à manufaturabilidade e leque de materiais disponíveis.Em último recurso, sem uma vacina ou ventiladores dispendiosos e raros, este estudo aponta um caminho viável de baixo-custo.Since the Wuhan coronavirus outbreak in China, It is expected that India the second most populated country in the world will take the lead in terms of infections and deaths caused by this pandemic. The year 2020 has seen an unexpected 120% increase in demand for invasive respiratory ventilators, necessary life-support equipment when treating critical-state patients. Well established ventilator companies have not anticipated this type of market growth, resulting in a massive world-wide shortage for this precious medical device.The main objective of the work presented is the development of an accessible, low-cost, “pandemic-grade” ventilator’s manifold component, defined as: “[A pipe or chamber branching into several other openings]” The intention is to lower the cost of traditional ventilators, and to increase the compatibility with off-the-shelf products, easily available during a pandemic crisis.The theory of mechanical ventilation is based upon a series of air channels upon which the manifold incorporates all the electronics and mechanical hardware needed, coming together as one functional product, capable of supplying Oxygen and to save a human life.An intensive study was made around patient-machine topologies, mechanical functioning principle, fluid dynamics and methods of ventilator manufacturing and material-science, resulting in a selected architectural solution for prototyping and testing, The heart of this life-saving machine is electronically monitored and mechanically composed of valves, sensors, manifolds, and various fittings. This work mainly focuses on the development of a ventilator’s manifold geometry, compatible with off-the-shelf products available during a pandemic emergency. The ventilation principles studied and learned from the development of “Project_Atena” (The first Portuguese Mechanical Invasive Ventilator) were tested, proven, and used as a reference during the study and work done for this master’s degree thesis. In the end, a new architecture has been conceived to build such a device, being capable of providing essential results on the manufacturability, range of materials, components, and manufacturing techniques world-wide. As a last resort scenario, without an available vaccine or expensive CE certified medical equipment, this study shines a light on an affordable solution for everyone in need.2020-12-292026-12-28T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/93975http://hdl.handle.net/10316/93975TID:202687244engPimentel, Henrique Fonseca Alvesinfo:eu-repo/semantics/embargoedAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-27T11:00:08Zoai:estudogeral.uc.pt:10316/93975Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:12:49.354936Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Respiratory Pandemic Ventilator: Mechanical development Ventilador Pulmonar pandémico: desenvolvimento mecânico |
title |
Respiratory Pandemic Ventilator: Mechanical development |
spellingShingle |
Respiratory Pandemic Ventilator: Mechanical development Pimentel, Henrique Fonseca Alves Ventilador Coletor Baixo custo Pandémico Acessível Ventilator Manifold low-cost Pandemic off-the-shelf |
title_short |
Respiratory Pandemic Ventilator: Mechanical development |
title_full |
Respiratory Pandemic Ventilator: Mechanical development |
title_fullStr |
Respiratory Pandemic Ventilator: Mechanical development |
title_full_unstemmed |
Respiratory Pandemic Ventilator: Mechanical development |
title_sort |
Respiratory Pandemic Ventilator: Mechanical development |
author |
Pimentel, Henrique Fonseca Alves |
author_facet |
Pimentel, Henrique Fonseca Alves |
author_role |
author |
dc.contributor.author.fl_str_mv |
Pimentel, Henrique Fonseca Alves |
dc.subject.por.fl_str_mv |
Ventilador Coletor Baixo custo Pandémico Acessível Ventilator Manifold low-cost Pandemic off-the-shelf |
topic |
Ventilador Coletor Baixo custo Pandémico Acessível Ventilator Manifold low-cost Pandemic off-the-shelf |
description |
Dissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-29 2026-12-28T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/93975 http://hdl.handle.net/10316/93975 TID:202687244 |
url |
http://hdl.handle.net/10316/93975 |
identifier_str_mv |
TID:202687244 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/embargoedAccess |
eu_rights_str_mv |
embargoedAccess |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799134023651426304 |