Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/5005 https://doi.org/10.1016/j.talanta.2008.02.005 |
Resumo: | Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5 × 10-7 to 3.5 × 10-4 mol L-1, in 0.1 mol L-1 sulfuric acid electrolyte, as well as high sensitivity, 0.110 A mol-1 L cm-2 at the optimized flow rate. A detection limit of 7.6 × 10-8 mol L-1 and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 [mu]L and a flow rate of 2.0 mL min-1. The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0 × 10-6 and 6.0 × 10-5 mol L-1 ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis. |
id |
RCAP_947f6059bc7658b7e7e2cadfe0efdd05 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/5005 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxolFlow injection analysisCarbon film electrodesAmbroxolAmperometryPharmaceutical productsFlow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5 × 10-7 to 3.5 × 10-4 mol L-1, in 0.1 mol L-1 sulfuric acid electrolyte, as well as high sensitivity, 0.110 A mol-1 L cm-2 at the optimized flow rate. A detection limit of 7.6 × 10-8 mol L-1 and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 [mu]L and a flow rate of 2.0 mL min-1. The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0 × 10-6 and 6.0 × 10-5 mol L-1 ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis.http://www.sciencedirect.com/science/article/B6THP-4RW434G-1/1/d40a3f00a2eaccb84817b064f601d0f22008info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/5005http://hdl.handle.net/10316/5005https://doi.org/10.1016/j.talanta.2008.02.005engTalanta. 76:1 (2008) 128-133Felix, Fabiana S.Brett, Christopher M. A.Angnes, Lúcioinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2021-07-27T09:48:12Zoai:estudogeral.uc.pt:10316/5005Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:01:15.893094Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol |
title |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol |
spellingShingle |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol Felix, Fabiana S. Flow injection analysis Carbon film electrodes Ambroxol Amperometry Pharmaceutical products |
title_short |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol |
title_full |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol |
title_fullStr |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol |
title_full_unstemmed |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol |
title_sort |
Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol |
author |
Felix, Fabiana S. |
author_facet |
Felix, Fabiana S. Brett, Christopher M. A. Angnes, Lúcio |
author_role |
author |
author2 |
Brett, Christopher M. A. Angnes, Lúcio |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Felix, Fabiana S. Brett, Christopher M. A. Angnes, Lúcio |
dc.subject.por.fl_str_mv |
Flow injection analysis Carbon film electrodes Ambroxol Amperometry Pharmaceutical products |
topic |
Flow injection analysis Carbon film electrodes Ambroxol Amperometry Pharmaceutical products |
description |
Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5 × 10-7 to 3.5 × 10-4 mol L-1, in 0.1 mol L-1 sulfuric acid electrolyte, as well as high sensitivity, 0.110 A mol-1 L cm-2 at the optimized flow rate. A detection limit of 7.6 × 10-8 mol L-1 and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 [mu]L and a flow rate of 2.0 mL min-1. The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0 × 10-6 and 6.0 × 10-5 mol L-1 ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/5005 http://hdl.handle.net/10316/5005 https://doi.org/10.1016/j.talanta.2008.02.005 |
url |
http://hdl.handle.net/10316/5005 https://doi.org/10.1016/j.talanta.2008.02.005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Talanta. 76:1 (2008) 128-133 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133904813162496 |