New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/89526 |
Resumo: | Trabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de Medicina |
id |
RCAP_98588051a993682a7fdcd4a86dee7ec3 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/89526 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis SurgeryNova Metodologia de Avaliação dos Resultados Estéticos e Funcionais após Cirurgia de PtosePtose palpebralCirurgiaPálpebraMediçõesFotografiaBlepharoptosisSurgeryEyelidMeasurementsPhotographyTrabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de MedicinaIntrodução: Para uma correta avaliação de uma ptose palpebral, planeamento cirúrgico e follow-up são necessárias medições palpebrais extremamente precisas. O recurso a uma metodologia que através de fotografias faciais mede automaticamente as distâncias margem-reflexo 1 e 2 (MRD1 e MRD2) e abertura palpebral (PF) poderá ser a resposta para uma abordagem objetiva, exata e reprodutível.Objetivo: Apresentar uma nova metodologia digital de medições palpebrais para a avaliação estética e funcional da ptose palpebral, e comparar a sua concordância com o método manual clássico.Métodos: Um total de 16 olhos de 8 pacientes referenciados por ptose palpebral ao serviço de Oftalmologia do Centro Hospitalar e Universitário de Coimbra, foram avaliados na consulta pré e pós-operatória, tendo sido medidos o MRD1, MRD2 e PF. As medições foram feitas manualmente com uma régua, e digitalmente utilizando a máquina fotográfica Volk Eye Check. Desvios sistemáticos foram avaliados recorrendo a testes t para dados emparelhados, concordância através da construção de gráficos Bland-Altman, e consistência pelo cálculo de coeficientes de correlação intra-classe (ICC).Resultados: As duas metodologias avaliaram eficazmente os aumentos dos parâmetros após a intervenção cirúrgica, sendo significativos os do MRD1 manual (p<0.001) e digital (p=0.003), MRD2 (p=0.004) e PF (p<0.001) manuais; e não significativos os do MRD2 (p=0.398) e PF (p=0.689) digitais. Não houve desvio sistemático significativo entre as medições manuais e digitais relativamente ao MRD1 (+0.01±1.37 mm, p=0.961) e houve um desvio significativo de +0.91±1.20 mm (p=0.002) no MRD2 e +1.33±1.68 mm (p=0.001) na PF. O intervalo de confiança de 95% de [-2.675, +2.704] para o MRD1, [-1.442, +3.267] para o MRD2 e [-1.956, +4.621] para a PF excederam os limites clinicamente aceitáveis de ±0.5 mm para o MRD1 e MRD2, e ±1.00 mm para a PF. O ICC calculado foi de 0.54 para o MRD1, 0.33 para o MRD2 e 0.55 para a PF, representando consistência moderada, fraca e moderada, respetivamente.Conclusão: Dada a fraca concordância observada entre as metodologias, os nossos dados sustentam que as medições digitais palpebrais recorrendo à versão atual desta tecnologia, não devem substituir o gold standard das medições manuais.Introduction: An extremely precise measurement of the margin reflex distance 1 (MRD1), margin reflex distance 2 (MRD2) and the palpebral fissure (PF) are crucial for a proper ptosis assessment, its surgical repair planning and follow-up. Facial photographs integrated with automated measurements of the eyelid position could represent an objective, accurate and reproducible means of documentation of these parameters.Purpose: To compare the agreement of eyelid position measurements between a novel device that automatically derives measurements from a digital photograph and the standard manual approach.Methods: A total of 16 eyes from 8 patients referred for blepharoptosis repair to the ophthalmology department of Centro Hospitalar e Universitário de Coimbra were assessed for MRD1, MRD2 and PF at the pre-operative and post-operative appointment. The measurements were obtained using two techniques: the standard manual approach, with the use of a ruler; and an automated digital approach, through which facial photographs captured using the Volk Eye Check oculoplastic device. Systematic differences were evaluated by paired t-tests, agreement by construction of Bland-Altman plots and consistency by deriving intra-class correlation coefficients (ICC).Results: Both manual and digital techniques succeeded in reporting after surgery increases: significantly for MRD1 manual (p<0.001) and digital (p=0.003), manual MRD2 (p=0.004) and PF (p<0.001); not significantly for digital MRD2 (p=0.398) and PF (p=0.689). There was no significant systematic difference between the manual and digital methodologies regarding the MRD1 (+0.01±1.37 mm, p=0.961); and a significant +0.91±1.20 mm (p=0.002) for MRD2 and +1.33±1.68 mm (p=0.001) for PF. The derived 95% confidence interval (CI) of [-2.675, +2.704] for MRD1, [-1.442, +3.267] for MRD2 and [-1.956, +4.621] for PF exceeded the acceptable clinical limits of ±0.5 mm for MRD1 and MRD2, and ±1.00 mm for PF. The calculated ICC was 0.54 for MRD1, 0.33 for MRD2 and 0.55 for PF, representing moderate, poor and moderate consistency, respectively.Conclusion: Our data supports that the digital measurements using the present version of this technology should not be used interchangeably with manual eyelid measurements, the gold standard, as a poor agreement between the methods was found.2019-06-07info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/89526http://hdl.handle.net/10316/89526TID:202477614engCunha, Bruna Maria Mota Antunes dainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T01:42:06Zoai:estudogeral.uc.pt:10316/89526Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:09:48.730965Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery Nova Metodologia de Avaliação dos Resultados Estéticos e Funcionais após Cirurgia de Ptose |
title |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery |
spellingShingle |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery Cunha, Bruna Maria Mota Antunes da Ptose palpebral Cirurgia Pálpebra Medições Fotografia Blepharoptosis Surgery Eyelid Measurements Photography |
title_short |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery |
title_full |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery |
title_fullStr |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery |
title_full_unstemmed |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery |
title_sort |
New Methodology to Evaluate Aesthetics and Functional Results after Ptosis Surgery |
author |
Cunha, Bruna Maria Mota Antunes da |
author_facet |
Cunha, Bruna Maria Mota Antunes da |
author_role |
author |
dc.contributor.author.fl_str_mv |
Cunha, Bruna Maria Mota Antunes da |
dc.subject.por.fl_str_mv |
Ptose palpebral Cirurgia Pálpebra Medições Fotografia Blepharoptosis Surgery Eyelid Measurements Photography |
topic |
Ptose palpebral Cirurgia Pálpebra Medições Fotografia Blepharoptosis Surgery Eyelid Measurements Photography |
description |
Trabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de Medicina |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-06-07 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/89526 http://hdl.handle.net/10316/89526 TID:202477614 |
url |
http://hdl.handle.net/10316/89526 |
identifier_str_mv |
TID:202477614 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133992966946816 |