Accuracy of the new rapid test for monitoring adalimumab levels
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10451/39728 |
Resumo: | © The Author(s), 2019. |
id |
RCAP_ab881dca0842438d76664cec34e9ee7f |
---|---|
oai_identifier_str |
oai:repositorio.ul.pt:10451/39728 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Accuracy of the new rapid test for monitoring adalimumab levelsAdalimumabQuantum Blue® AdalimumabTherapeutic drug monitoring© The Author(s), 2019.Background: The loss of response to adalimumab (ADL) has been related to low serum concentrations at trough. Currently, most methods commercially available for the quantification of ADL are enzyme-linked immunosorbent assay (ELISA) based, with a turnaround time of approximately 8 h, delaying the target dosage adjustment to the subsequent infusion. In this study, we aimed to evaluate the performance of the newly available rapid-test ADL quantification assay by comparing it with three established ELISA methods, using spiked samples and a set of clinical samples. Methods: Spiked samples from control donors and 120 serum samples from inflammatory bowel disease (IBD) patients undergoing ADL therapy were quantified using lateral flow Quantum Blue® Adalimumab and, the ELISA formats from Immundiagnostik, R-Biopharm and an in-house assay. Results: The rapid-test assay had intraclass correlation coefficients of 0.590, 0.864 and 0.761 when comparing with the Immundiagnostik, R-Biopharm and in-house assays, respectively. For the five therapeutic windows, the accuracy was high: ADL rapid test compared with the Immundiagnostik (58–88%); R-Biopharm, 68–89%; and in house, 60–88%; and kappa statistics revealed 0.492–0.602, 0.531–0.659 and 0.545–0.682, respectively. Conclusions: The Quantum Blue® Adalimumab assay can replace the commonly used ELISAbased ADL quantification kits and it is a reliable alternative to these methods. This rapidtest assay enables the quantitative determination of ADL serum trough level in only 15 min. The developed assay allows measurement of ADL over a wide range. Hence, it represents a valuable tool for the clinician to assess the ADL trough level.This work was supported by the Portuguese IBD Group (GEDII, Grupo de Estudo da Doença Inflamatória Intestinal).SAGE PublicationsRepositório da Universidade de LisboaRocha, CátiaAfonso, JoanaLago, PaulaArroja, BrunoVieira, Ana I.Dias, Cláudia C.Magro, Fernando2019-10-08T11:13:15Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10451/39728engTher Adv Gastroenterol 2019, Vol. 12: 1–111756-283X10.1177/1756284819828238info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-11-20T17:53:35Zoai:repositorio.ul.pt:10451/39728Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-11-20T17:53:35Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Accuracy of the new rapid test for monitoring adalimumab levels |
title |
Accuracy of the new rapid test for monitoring adalimumab levels |
spellingShingle |
Accuracy of the new rapid test for monitoring adalimumab levels Rocha, Cátia Adalimumab Quantum Blue® Adalimumab Therapeutic drug monitoring |
title_short |
Accuracy of the new rapid test for monitoring adalimumab levels |
title_full |
Accuracy of the new rapid test for monitoring adalimumab levels |
title_fullStr |
Accuracy of the new rapid test for monitoring adalimumab levels |
title_full_unstemmed |
Accuracy of the new rapid test for monitoring adalimumab levels |
title_sort |
Accuracy of the new rapid test for monitoring adalimumab levels |
author |
Rocha, Cátia |
author_facet |
Rocha, Cátia Afonso, Joana Lago, Paula Arroja, Bruno Vieira, Ana I. Dias, Cláudia C. Magro, Fernando |
author_role |
author |
author2 |
Afonso, Joana Lago, Paula Arroja, Bruno Vieira, Ana I. Dias, Cláudia C. Magro, Fernando |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório da Universidade de Lisboa |
dc.contributor.author.fl_str_mv |
Rocha, Cátia Afonso, Joana Lago, Paula Arroja, Bruno Vieira, Ana I. Dias, Cláudia C. Magro, Fernando |
dc.subject.por.fl_str_mv |
Adalimumab Quantum Blue® Adalimumab Therapeutic drug monitoring |
topic |
Adalimumab Quantum Blue® Adalimumab Therapeutic drug monitoring |
description |
© The Author(s), 2019. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-10-08T11:13:15Z 2019 2019-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10451/39728 |
url |
http://hdl.handle.net/10451/39728 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Ther Adv Gastroenterol 2019, Vol. 12: 1–11 1756-283X 10.1177/1756284819828238 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
SAGE Publications |
publisher.none.fl_str_mv |
SAGE Publications |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817549062452281344 |