Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes

Detalhes bibliográficos
Autor(a) principal: Florescu, Monica
Data de Publicação: 2005
Outros Autores: Brett, Christopher M. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/5113
https://doi.org/10.1016/j.talanta.2004.07.003
Resumo: Electrochemical glucose enzyme biosensors have been prepared on carbon film electrodes made from carbon film electrical resistors. Evaluation and characterisation of these electrodes in phosphate buffer saline solution has been carried out with and without pretreatment by cycling in perchloric acid or at fixed applied potential. Both pretreatments led to a reduction in the carbon surface oxidation peak and enabled better detection of hydrogen peroxide in the pH range of 5-7. Glucose oxidase enzyme was immobilised on the carbon surface by mixing with glutaraldehyde, bovine serum albumin and with and without Nafion. The performance of these two types of electrode was similar, that containing Nafion being more physically robust. Linear ranges were up to around 1.5 mM, with detection limits 60 [mu]M, and pretreatment of the carbon film electrode at a fixed potential of +0.9 V versus SCE for 5 min was found to be the most beneficial. Michaelis-Menten constants between 5 mM and 10 mM were found under the different experimental conditions. Coating the immobilised enzyme layer with a thin layer of Nafion was found to give similar results in the determination of glucose to mixing it but with benefits against interferences for the analysis of complex matrices, such as wine. Potentialities, for a short-term-use or disposable sensors, are indicated.
id RCAP_bf44c6343c1e04218a193c5befac1d7d
oai_identifier_str oai:estudogeral.uc.pt:10316/5113
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodesCarbon filmElectrochemical biosensorGlucoseElectrochemical glucose enzyme biosensors have been prepared on carbon film electrodes made from carbon film electrical resistors. Evaluation and characterisation of these electrodes in phosphate buffer saline solution has been carried out with and without pretreatment by cycling in perchloric acid or at fixed applied potential. Both pretreatments led to a reduction in the carbon surface oxidation peak and enabled better detection of hydrogen peroxide in the pH range of 5-7. Glucose oxidase enzyme was immobilised on the carbon surface by mixing with glutaraldehyde, bovine serum albumin and with and without Nafion. The performance of these two types of electrode was similar, that containing Nafion being more physically robust. Linear ranges were up to around 1.5 mM, with detection limits 60 [mu]M, and pretreatment of the carbon film electrode at a fixed potential of +0.9 V versus SCE for 5 min was found to be the most beneficial. Michaelis-Menten constants between 5 mM and 10 mM were found under the different experimental conditions. Coating the immobilised enzyme layer with a thin layer of Nafion was found to give similar results in the determination of glucose to mixing it but with benefits against interferences for the analysis of complex matrices, such as wine. Potentialities, for a short-term-use or disposable sensors, are indicated.http://www.sciencedirect.com/science/article/B6THP-4D268VV-4/1/7a2a399ad9f6b3fd4d087e658113f82d2005info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/5113http://hdl.handle.net/10316/5113https://doi.org/10.1016/j.talanta.2004.07.003engTalanta. 65:2 (2005) 306-312Florescu, MonicaBrett, Christopher M. A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T16:59:21Zoai:estudogeral.uc.pt:10316/5113Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:01:24.641818Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
title Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
spellingShingle Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
Florescu, Monica
Carbon film
Electrochemical biosensor
Glucose
title_short Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
title_full Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
title_fullStr Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
title_full_unstemmed Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
title_sort Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes
author Florescu, Monica
author_facet Florescu, Monica
Brett, Christopher M. A.
author_role author
author2 Brett, Christopher M. A.
author2_role author
dc.contributor.author.fl_str_mv Florescu, Monica
Brett, Christopher M. A.
dc.subject.por.fl_str_mv Carbon film
Electrochemical biosensor
Glucose
topic Carbon film
Electrochemical biosensor
Glucose
description Electrochemical glucose enzyme biosensors have been prepared on carbon film electrodes made from carbon film electrical resistors. Evaluation and characterisation of these electrodes in phosphate buffer saline solution has been carried out with and without pretreatment by cycling in perchloric acid or at fixed applied potential. Both pretreatments led to a reduction in the carbon surface oxidation peak and enabled better detection of hydrogen peroxide in the pH range of 5-7. Glucose oxidase enzyme was immobilised on the carbon surface by mixing with glutaraldehyde, bovine serum albumin and with and without Nafion. The performance of these two types of electrode was similar, that containing Nafion being more physically robust. Linear ranges were up to around 1.5 mM, with detection limits 60 [mu]M, and pretreatment of the carbon film electrode at a fixed potential of +0.9 V versus SCE for 5 min was found to be the most beneficial. Michaelis-Menten constants between 5 mM and 10 mM were found under the different experimental conditions. Coating the immobilised enzyme layer with a thin layer of Nafion was found to give similar results in the determination of glucose to mixing it but with benefits against interferences for the analysis of complex matrices, such as wine. Potentialities, for a short-term-use or disposable sensors, are indicated.
publishDate 2005
dc.date.none.fl_str_mv 2005
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/5113
http://hdl.handle.net/10316/5113
https://doi.org/10.1016/j.talanta.2004.07.003
url http://hdl.handle.net/10316/5113
https://doi.org/10.1016/j.talanta.2004.07.003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Talanta. 65:2 (2005) 306-312
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133905752686592