Synthetic oligonucleotides: AFM characterisation and electroanalytical studies

Detalhes bibliográficos
Autor(a) principal: Brett, A. M. Oliveira
Data de Publicação: 2005
Outros Autores: Paquim, A. M. Chiorcea, Diculescu, V., Oretskaya, T. S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/5100
https://doi.org/10.1016/j.bioelechem.2004.06.008
Resumo: One of the most important steps in designing more sensitive and stable DNA based biosensors is the immobilisation procedure of the nucleic acid probes on the transducer surface, while maintaining their conformational flexibility. MAC Mode AFM images in air demonstrated that the oligonucleotide sequences adsorb spontaneously on the electrode surface, showing the existence of pores in the adsorbed layer that reveal big parts of the electrode surface, which enables non-specific adsorption of other molecules on the uncovered areas. The electrostatic immobilisation onto a glassy carbon electrode followed by hybridisation with a complementary sequence and control with a non-complementary sequence was studied using differential pulse voltammetry and electrochemical impedance spectroscopy. Changes in the oxidation currents of guanosine and adenosine were observed after hybridisation events as well as after control experiments. Modification of the double layer capacitance that took place after hybridisation or control experiments showed that non-specific adsorption of complementary or non-complementary sequences occur allowing the formation of a mixed multilayer.
id RCAP_ced3ba05d074e4fc7d8458c34d0781ef
oai_identifier_str oai:estudogeral.uc.pt:10316/5100
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Synthetic oligonucleotides: AFM characterisation and electroanalytical studiesDNA biosensorHybridisationAdsorptionNon-specific adsorptionOne of the most important steps in designing more sensitive and stable DNA based biosensors is the immobilisation procedure of the nucleic acid probes on the transducer surface, while maintaining their conformational flexibility. MAC Mode AFM images in air demonstrated that the oligonucleotide sequences adsorb spontaneously on the electrode surface, showing the existence of pores in the adsorbed layer that reveal big parts of the electrode surface, which enables non-specific adsorption of other molecules on the uncovered areas. The electrostatic immobilisation onto a glassy carbon electrode followed by hybridisation with a complementary sequence and control with a non-complementary sequence was studied using differential pulse voltammetry and electrochemical impedance spectroscopy. Changes in the oxidation currents of guanosine and adenosine were observed after hybridisation events as well as after control experiments. Modification of the double layer capacitance that took place after hybridisation or control experiments showed that non-specific adsorption of complementary or non-complementary sequences occur allowing the formation of a mixed multilayer.http://www.sciencedirect.com/science/article/B6W72-4GP1VK1-1/1/c44e3d2a4c722d5cec59a4d09d0a744c2005info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/5100http://hdl.handle.net/10316/5100https://doi.org/10.1016/j.bioelechem.2004.06.008engBioelectrochemistry. 67:2 (2005) 181-190Brett, A. M. OliveiraPaquim, A. M. ChiorceaDiculescu, V.Oretskaya, T. S.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T16:48:50Zoai:estudogeral.uc.pt:10316/5100Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:01:38.758641Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
title Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
spellingShingle Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
Brett, A. M. Oliveira
DNA biosensor
Hybridisation
Adsorption
Non-specific adsorption
title_short Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
title_full Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
title_fullStr Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
title_full_unstemmed Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
title_sort Synthetic oligonucleotides: AFM characterisation and electroanalytical studies
author Brett, A. M. Oliveira
author_facet Brett, A. M. Oliveira
Paquim, A. M. Chiorcea
Diculescu, V.
Oretskaya, T. S.
author_role author
author2 Paquim, A. M. Chiorcea
Diculescu, V.
Oretskaya, T. S.
author2_role author
author
author
dc.contributor.author.fl_str_mv Brett, A. M. Oliveira
Paquim, A. M. Chiorcea
Diculescu, V.
Oretskaya, T. S.
dc.subject.por.fl_str_mv DNA biosensor
Hybridisation
Adsorption
Non-specific adsorption
topic DNA biosensor
Hybridisation
Adsorption
Non-specific adsorption
description One of the most important steps in designing more sensitive and stable DNA based biosensors is the immobilisation procedure of the nucleic acid probes on the transducer surface, while maintaining their conformational flexibility. MAC Mode AFM images in air demonstrated that the oligonucleotide sequences adsorb spontaneously on the electrode surface, showing the existence of pores in the adsorbed layer that reveal big parts of the electrode surface, which enables non-specific adsorption of other molecules on the uncovered areas. The electrostatic immobilisation onto a glassy carbon electrode followed by hybridisation with a complementary sequence and control with a non-complementary sequence was studied using differential pulse voltammetry and electrochemical impedance spectroscopy. Changes in the oxidation currents of guanosine and adenosine were observed after hybridisation events as well as after control experiments. Modification of the double layer capacitance that took place after hybridisation or control experiments showed that non-specific adsorption of complementary or non-complementary sequences occur allowing the formation of a mixed multilayer.
publishDate 2005
dc.date.none.fl_str_mv 2005
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/5100
http://hdl.handle.net/10316/5100
https://doi.org/10.1016/j.bioelechem.2004.06.008
url http://hdl.handle.net/10316/5100
https://doi.org/10.1016/j.bioelechem.2004.06.008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Bioelectrochemistry. 67:2 (2005) 181-190
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133907397902336