Low intensity focused ultrasound modulation of neuronal circuits activity

Detalhes bibliográficos
Autor(a) principal: Machado, Francisca Araújo Guedes
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/77507
Resumo: Dissertação de Mestrado Integrado em Engenharia Biomédica (Ramo de Eletrónica Médica)
id RCAP_dae3978c00396298477338f46cf136d7
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/77507
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Low intensity focused ultrasound modulation of neuronal circuits activityModulação da atividade de circuitos neuronais com ultrassons focados de baixa intensidadeneuromodulaçãoultrassonsultrassons focadoseletrofisiologiatétrodosclassificação de disparos neuronaisneuromodulationultrasoundfocused ultrasoundelectrophysiologytetrodesspike sortingEngenharia e Tecnologia::Outras Engenharias e TecnologiasDissertação de Mestrado Integrado em Engenharia Biomédica (Ramo de Eletrónica Médica)O uso de ultrassons focados (FUS) corresponde a uma técnica de neuromodulação não invasiva que ganhou destaque nas últimas décadas devido à sua capacidade de modificar reversivelmente a atividade neuronal com alta precisão espacial. Como tal, FUS foi reconhecido como um forte candidato para a substituição de técnicas convencionais de neuromodulação, como a estimulação cerebral profunda (DBS) e a estimulação magnética transcraniana (TMS) no tratamento de doenças neurológicas humanas. Contudo, a falta de protocolos padronizados e de consenso na comunidade científica relativamente aos mecanismos responsáveis pelas respostas neuronais induzidas por FUS, representam barreiras críticas ao avanço desta técnica para ensaios clínicos. O objetivo principal da presente dissertação de mestrado foi a implementação de um sistema de ultrassons capaz de fornecer ultrassons focados de baixa intensidade (LIFUS) a circuitos neuronais, utilizando fatias de cérebro ex vivo. Um protocolo experimental foi desenvolvido com base na literatura de neuromodulação por ultrassons, de forma a permitir o estudo de uma ampla gama de parâmetros de sonicação, juntamente com os resultados subsequentes da modulação na atividade neuronal. Com o intuito de verificar as alterações induzidas pelos ultrassons na atividade elétrica dos neurónios alvo, um novo protótipo de registo eletrofisiológico, baseado em tétrodos, foi desenvolvido para registar a atividade neuronal extracelular em fatias de cérebro de forma econômica e reproduzível. Adicionalmente, um novo algoritmo de classificação de disparos neuronais semi-supervisionado foi desenvolvido para isolar neurônios, possibilitando a análise da resposta de neurónios individuais ao LIFUS. O novo protótipo e o algoritmo de classificação foram validados com estimulação optogenética, utilizada como controlo positivo para verificar a capacidade do novo protótipo de registar alterações na atividade evocada por estímulos externos. Em suma, este estudo forneceu uma base de engenharia, desde a especificação e instalação de um novo sistema de ultrassons até ao desenvolvimento de novas ferramentas para registar e analisar a atividade neuronal em resposta a estímulos externos – para futuras investigações sistemáticas e reproduzíveis dos efeitos neuromodulatórios do LIFUS. Este estudo será essencial para promover o LIFUS como uma via de tratamento de distúrbios neurológicos ou psiquiátricos humanos.Focused ultrasound (FUS) is a non-invasive neuromodulation technique which has gained momentum over the past few decades due to its capability of reversibly modifying neuronal activity with high spatial accuracy. Therefore, FUS has been remarked as a strong candidate for replacing conventional neuromodulation techniques such as deep brain stimulation (DBS) and transcranial magnetic stimulation (TMS) in the treatment of human neurologic diseases. Nonetheless, the lack of standardized protocols and consensus in the scientific community regarding the mechanisms behind FUS-induced neuronal responses represent critical barriers to the advancement of this technique into clinical trials. The primary goal of this master’s dissertation was to implement an ultrasound system capable of delivering low intensity focused ultrasound (LIFUS) to neuronal cells in, ex vivo rodent brain slices. An experimental protocol was developed based on an extensive revision of ultrasound neuromodulation literature, that allows the study of a broad range of sonication parameters and the subsequent modulation outcomes on neuronal activity. In order to verify the ultrasound-induced modifications in the electrical activity of the targeted neurons, a new electrophysiology recording prototype, based on tetrodes, was developed to record extracellular neuronal activity in brain slices in a cost-effective and reproducible manner. Moreover, a new semi-supervised spike sorting algorithm was developed to isolate single neurons, allowing the analysis of the individual neuron’s response to LIFUS. Both the new prototype and spike sorting algorithm were validated with optogenetic stimulation, used as a positive control to verify the prototype’s ability to record alterations in evoked activity by external stimuli. In conclusion, this study provided an engineering foundation, from the specification and installation of a new US system to the development of new tools to record and analyze neuronal activity in response to external stimuli – for future systematic and reproducible investigations of LIFUS neuromodulatory effects. In particular, the developed framework will allow future promising research, including the unveiling of possible mechanisms of action for LIFUS on neuronal activity but also the optimization of sonication parameters in order to obtain safer and controllable neuromodulation. This research will be essential in order to advance LIFUS as a route for the treatment of human neurologic or psychiatric disorders.Mendes, P. M.Magalhães, Ricardo José da SilvaUniversidade do MinhoMachado, Francisca Araújo Guedes20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/1822/77507por202546942info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:18:10Zoai:repositorium.sdum.uminho.pt:1822/77507Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:10:56.224832Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Low intensity focused ultrasound modulation of neuronal circuits activity
Modulação da atividade de circuitos neuronais com ultrassons focados de baixa intensidade
title Low intensity focused ultrasound modulation of neuronal circuits activity
spellingShingle Low intensity focused ultrasound modulation of neuronal circuits activity
Machado, Francisca Araújo Guedes
neuromodulação
ultrassons
ultrassons focados
eletrofisiologia
tétrodos
classificação de disparos neuronais
neuromodulation
ultrasound
focused ultrasound
electrophysiology
tetrodes
spike sorting
Engenharia e Tecnologia::Outras Engenharias e Tecnologias
title_short Low intensity focused ultrasound modulation of neuronal circuits activity
title_full Low intensity focused ultrasound modulation of neuronal circuits activity
title_fullStr Low intensity focused ultrasound modulation of neuronal circuits activity
title_full_unstemmed Low intensity focused ultrasound modulation of neuronal circuits activity
title_sort Low intensity focused ultrasound modulation of neuronal circuits activity
author Machado, Francisca Araújo Guedes
author_facet Machado, Francisca Araújo Guedes
author_role author
dc.contributor.none.fl_str_mv Mendes, P. M.
Magalhães, Ricardo José da Silva
Universidade do Minho
dc.contributor.author.fl_str_mv Machado, Francisca Araújo Guedes
dc.subject.por.fl_str_mv neuromodulação
ultrassons
ultrassons focados
eletrofisiologia
tétrodos
classificação de disparos neuronais
neuromodulation
ultrasound
focused ultrasound
electrophysiology
tetrodes
spike sorting
Engenharia e Tecnologia::Outras Engenharias e Tecnologias
topic neuromodulação
ultrassons
ultrassons focados
eletrofisiologia
tétrodos
classificação de disparos neuronais
neuromodulation
ultrasound
focused ultrasound
electrophysiology
tetrodes
spike sorting
Engenharia e Tecnologia::Outras Engenharias e Tecnologias
description Dissertação de Mestrado Integrado em Engenharia Biomédica (Ramo de Eletrónica Médica)
publishDate 2019
dc.date.none.fl_str_mv 2019
2019-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/77507
url http://hdl.handle.net/1822/77507
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv 202546942
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132540421799936