Resumo: | PURPOSE: To describe a cadaver model and to compare different techniques to correct midline incisional hernia using the tension at the musculoaponeurotic layer as a parameter. METHODS: Twenty-four male cadavers were used to characterize the model. The tensile force applied to the anterior layers of the rectus abdominis muscle was measured after the linea alba was resected to create an abdominal wall defect. A dynamometer was used to measure the tensile force necessary to cause a 10-mm displacement of the tissues towards the midline. An index that allows comparison of tensile forces from different points was calculated by dividing the tensile force by the distance between the point of force application at the aponeurosis and the midline. RESULTS: Cadaver is a good model for the study of midline incisional hernia. CONCLUSION: Cadaver can be used effectively as a model to evaluate tension of the abdominal wall when tissue advancement and musculoaponeurotic flaps are performed in the repair of midline incisional hernia. |
id |
SBDPC-1_a1a912fa81db303b513e52c6cc60a601 |
---|---|
oai_identifier_str |
oai:scielo:S0102-86502011000400011 |
network_acronym_str |
SBDPC-1 |
network_name_str |
Acta Cirúrgica Brasileira (Online) |
repository_id_str |
|
spelling |
Cadaver as an experimental a model for the study of midline incisional herniaHernia, VentralAbdominal MusclesTensile StrengthRectus AbdominisCadaverPURPOSE: To describe a cadaver model and to compare different techniques to correct midline incisional hernia using the tension at the musculoaponeurotic layer as a parameter. METHODS: Twenty-four male cadavers were used to characterize the model. The tensile force applied to the anterior layers of the rectus abdominis muscle was measured after the linea alba was resected to create an abdominal wall defect. A dynamometer was used to measure the tensile force necessary to cause a 10-mm displacement of the tissues towards the midline. An index that allows comparison of tensile forces from different points was calculated by dividing the tensile force by the distance between the point of force application at the aponeurosis and the midline. RESULTS: Cadaver is a good model for the study of midline incisional hernia. CONCLUSION: Cadaver can be used effectively as a model to evaluate tension of the abdominal wall when tissue advancement and musculoaponeurotic flaps are performed in the repair of midline incisional hernia.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2011-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502011000400011Acta Cirúrgica Brasileira v.26 n.4 2011reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502011000400011info:eu-repo/semantics/openAccessSilveira,Romar Ângelo BarbatoNahas,Fábio XerfanHochman,BernardoBazzano,Felix Carlos OcarizAmorim,Carlos RobertoFerreira,Lydia Masakoeng2011-07-25T00:00:00Zoai:scielo:S0102-86502011000400011Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2011-07-25T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false |
dc.title.none.fl_str_mv |
Cadaver as an experimental a model for the study of midline incisional hernia |
title |
Cadaver as an experimental a model for the study of midline incisional hernia |
spellingShingle |
Cadaver as an experimental a model for the study of midline incisional hernia Silveira,Romar Ângelo Barbato Hernia, Ventral Abdominal Muscles Tensile Strength Rectus Abdominis Cadaver |
title_short |
Cadaver as an experimental a model for the study of midline incisional hernia |
title_full |
Cadaver as an experimental a model for the study of midline incisional hernia |
title_fullStr |
Cadaver as an experimental a model for the study of midline incisional hernia |
title_full_unstemmed |
Cadaver as an experimental a model for the study of midline incisional hernia |
title_sort |
Cadaver as an experimental a model for the study of midline incisional hernia |
author |
Silveira,Romar Ângelo Barbato |
author_facet |
Silveira,Romar Ângelo Barbato Nahas,Fábio Xerfan Hochman,Bernardo Bazzano,Felix Carlos Ocariz Amorim,Carlos Roberto Ferreira,Lydia Masako |
author_role |
author |
author2 |
Nahas,Fábio Xerfan Hochman,Bernardo Bazzano,Felix Carlos Ocariz Amorim,Carlos Roberto Ferreira,Lydia Masako |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Silveira,Romar Ângelo Barbato Nahas,Fábio Xerfan Hochman,Bernardo Bazzano,Felix Carlos Ocariz Amorim,Carlos Roberto Ferreira,Lydia Masako |
dc.subject.por.fl_str_mv |
Hernia, Ventral Abdominal Muscles Tensile Strength Rectus Abdominis Cadaver |
topic |
Hernia, Ventral Abdominal Muscles Tensile Strength Rectus Abdominis Cadaver |
description |
PURPOSE: To describe a cadaver model and to compare different techniques to correct midline incisional hernia using the tension at the musculoaponeurotic layer as a parameter. METHODS: Twenty-four male cadavers were used to characterize the model. The tensile force applied to the anterior layers of the rectus abdominis muscle was measured after the linea alba was resected to create an abdominal wall defect. A dynamometer was used to measure the tensile force necessary to cause a 10-mm displacement of the tissues towards the midline. An index that allows comparison of tensile forces from different points was calculated by dividing the tensile force by the distance between the point of force application at the aponeurosis and the midline. RESULTS: Cadaver is a good model for the study of midline incisional hernia. CONCLUSION: Cadaver can be used effectively as a model to evaluate tension of the abdominal wall when tissue advancement and musculoaponeurotic flaps are performed in the repair of midline incisional hernia. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502011000400011 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502011000400011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0102-86502011000400011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
publisher.none.fl_str_mv |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia |
dc.source.none.fl_str_mv |
Acta Cirúrgica Brasileira v.26 n.4 2011 reponame:Acta Cirúrgica Brasileira (Online) instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) instacron:SBDPC |
instname_str |
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
instacron_str |
SBDPC |
institution |
SBDPC |
reponame_str |
Acta Cirúrgica Brasileira (Online) |
collection |
Acta Cirúrgica Brasileira (Online) |
repository.name.fl_str_mv |
Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC) |
repository.mail.fl_str_mv |
||sgolden@terra.com.br |
_version_ |
1752126440408612864 |