Mapping traction strength of the anterior rectus sheath in cadaver

Detalhes bibliográficos
Autor(a) principal: Silveira, Romar Ângelo Barbato [UNIFESP]
Data de Publicação: 2010
Outros Autores: Nahas, Fabio Xerfan [UNIFESP], Hochman, Bernardo [UNIFESP], Bazzano, Felix Carlos Ocariz, Amorim, Carlos Roberto [UNIFESP], Juliano, Yara [UNIFESP], Passos, Volney Marques, Ferreira, Lydia Masako [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0102-86502010000400009
http://repositorio.unifesp.br/handle/11600/5886
Resumo: PURPOSE: The tension at the aponeurotic edges of abdominal wall defects is an important factor of dehiscence and incisional hernia formation. The purpose of this study is to map and compare the traction force necessary for medial mobilization in various levels of the anterior rectus sheath in cadavers. METHODS: Twenty four adult male cadavers, raging from 22 to 59 years old, with the abdominal wall intact and without prior preservation techniques, were dissected. A complete excision of the linea alba was performed. Traction loops of 10 mm in diameter were made in the anterior rectus sheath and were placed: 2, 4, 6 and 8 cm below the lower edge of the umbilicus and 3, 6 and 9 cm above the upper edge of the umbilicus. Each loop was mobilized 10 mm in the medial direction, using an analog dynamometer. The values obtained in each level were compared using Friedman's analysis of Variance for p < 0.05. RESULTS: The average traction values obtained at the various levels were compared and there was no statistical significant difference. CONCLUSION: There is no variation in tension along the whole extension of the anterior rectus sheath.
id UFSP_3a13306295f5a5a295020f6fd6d47d2b
oai_identifier_str oai:repositorio.unifesp.br/:11600/5886
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Mapping traction strength of the anterior rectus sheath in cadaverMapeamento da força de tração da lâmina anterior do músculo reto do abdome em cadáverHernia, VentralTensile StrengthCadaverHérnia VentralResistência à TraçãoCadaverPURPOSE: The tension at the aponeurotic edges of abdominal wall defects is an important factor of dehiscence and incisional hernia formation. The purpose of this study is to map and compare the traction force necessary for medial mobilization in various levels of the anterior rectus sheath in cadavers. METHODS: Twenty four adult male cadavers, raging from 22 to 59 years old, with the abdominal wall intact and without prior preservation techniques, were dissected. A complete excision of the linea alba was performed. Traction loops of 10 mm in diameter were made in the anterior rectus sheath and were placed: 2, 4, 6 and 8 cm below the lower edge of the umbilicus and 3, 6 and 9 cm above the upper edge of the umbilicus. Each loop was mobilized 10 mm in the medial direction, using an analog dynamometer. The values obtained in each level were compared using Friedman's analysis of Variance for p < 0.05. RESULTS: The average traction values obtained at the various levels were compared and there was no statistical significant difference. CONCLUSION: There is no variation in tension along the whole extension of the anterior rectus sheath.OBJETIVO: A tensão na margem da aponeurose de um defeito da parede abdominal é um importante fator de deiscência e formação da hérnia incisional. O objetivo deste estudo é mapear e comparar a força de tração necessária à mobilização medial em vários níveis da lâmina anterior do músculo reto do abdome em cadáveres. MÉTODOS: Vinte e quatro cadáveres adultos masculinos, com idade entre 22 e 59 anos, com a parede abdominal intacta e sem técnicas prévias de conservação, foram dissecados. Uma excisão completa da linha alba foi realizada. Alças de tração de 10 mm de diâmetro foram realizadas na lamina anterior do músculo reto do abdome e estavam localizadas: 2,4,6 e 8 cm abaixo da margem inferior do umbigo e 3,6 e 9 cm da margem superior do umbigo. Cada alça foi mobilizada 10 mm em direção medial, usando um dinamômetro analógico. Os valores obtidos em cada nível foram comparados usando a analise de variância de Friedman com p < 0,05. RESULTADOS: Os valores de tração obtidos nos vários níveis foram comparados e não apresentaram significância estatística. CONCLUSÃO: Não há variação de tensão por toda lamina anterior do músculo reto do abdome.Universidade Federal de São Paulo (UNIFESP) Department of Surgery Post-Graduation Program of Plastic SurgeryUNIFESP Division of Plastic SurgeryUNIVASUniversidade Federal de São Paulo (UNIFESP) Department of EpidemiologyUniversidade Federal de São Paulo (UNIFESP) Department of Surgery Division and ChairwomanUNIFESP, Department of Surgery Post-Graduation Program of Plastic SurgeryUNIFESP, Division of Plastic SurgeryUNIFESP, Department of EpidemiologyUNIFESP, Department of Surgery Division and ChairwomanSciELOSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaUniversidade Federal de São Paulo (UNIFESP)UNIVASSilveira, Romar Ângelo Barbato [UNIFESP]Nahas, Fabio Xerfan [UNIFESP]Hochman, Bernardo [UNIFESP]Bazzano, Felix Carlos OcarizAmorim, Carlos Roberto [UNIFESP]Juliano, Yara [UNIFESP]Passos, Volney MarquesFerreira, Lydia Masako [UNIFESP]2015-06-14T13:41:50Z2015-06-14T13:41:50Z2010-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion347-349application/pdfhttp://dx.doi.org/10.1590/S0102-86502010000400009Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 25, n. 4, p. 347-349, 2010.10.1590/S0102-86502010000400009S0102-86502010000400009.pdf0102-8650S0102-86502010000400009http://repositorio.unifesp.br/handle/11600/5886WOS:000280607200008engActa Cirurgica Brasileirainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-28T20:28:21Zoai:repositorio.unifesp.br/:11600/5886Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-28T20:28:21Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Mapping traction strength of the anterior rectus sheath in cadaver
Mapeamento da força de tração da lâmina anterior do músculo reto do abdome em cadáver
title Mapping traction strength of the anterior rectus sheath in cadaver
spellingShingle Mapping traction strength of the anterior rectus sheath in cadaver
Silveira, Romar Ângelo Barbato [UNIFESP]
Hernia, Ventral
Tensile Strength
Cadaver
Hérnia Ventral
Resistência à Tração
Cadaver
title_short Mapping traction strength of the anterior rectus sheath in cadaver
title_full Mapping traction strength of the anterior rectus sheath in cadaver
title_fullStr Mapping traction strength of the anterior rectus sheath in cadaver
title_full_unstemmed Mapping traction strength of the anterior rectus sheath in cadaver
title_sort Mapping traction strength of the anterior rectus sheath in cadaver
author Silveira, Romar Ângelo Barbato [UNIFESP]
author_facet Silveira, Romar Ângelo Barbato [UNIFESP]
Nahas, Fabio Xerfan [UNIFESP]
Hochman, Bernardo [UNIFESP]
Bazzano, Felix Carlos Ocariz
Amorim, Carlos Roberto [UNIFESP]
Juliano, Yara [UNIFESP]
Passos, Volney Marques
Ferreira, Lydia Masako [UNIFESP]
author_role author
author2 Nahas, Fabio Xerfan [UNIFESP]
Hochman, Bernardo [UNIFESP]
Bazzano, Felix Carlos Ocariz
Amorim, Carlos Roberto [UNIFESP]
Juliano, Yara [UNIFESP]
Passos, Volney Marques
Ferreira, Lydia Masako [UNIFESP]
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
UNIVAS
dc.contributor.author.fl_str_mv Silveira, Romar Ângelo Barbato [UNIFESP]
Nahas, Fabio Xerfan [UNIFESP]
Hochman, Bernardo [UNIFESP]
Bazzano, Felix Carlos Ocariz
Amorim, Carlos Roberto [UNIFESP]
Juliano, Yara [UNIFESP]
Passos, Volney Marques
Ferreira, Lydia Masako [UNIFESP]
dc.subject.por.fl_str_mv Hernia, Ventral
Tensile Strength
Cadaver
Hérnia Ventral
Resistência à Tração
Cadaver
topic Hernia, Ventral
Tensile Strength
Cadaver
Hérnia Ventral
Resistência à Tração
Cadaver
description PURPOSE: The tension at the aponeurotic edges of abdominal wall defects is an important factor of dehiscence and incisional hernia formation. The purpose of this study is to map and compare the traction force necessary for medial mobilization in various levels of the anterior rectus sheath in cadavers. METHODS: Twenty four adult male cadavers, raging from 22 to 59 years old, with the abdominal wall intact and without prior preservation techniques, were dissected. A complete excision of the linea alba was performed. Traction loops of 10 mm in diameter were made in the anterior rectus sheath and were placed: 2, 4, 6 and 8 cm below the lower edge of the umbilicus and 3, 6 and 9 cm above the upper edge of the umbilicus. Each loop was mobilized 10 mm in the medial direction, using an analog dynamometer. The values obtained in each level were compared using Friedman's analysis of Variance for p < 0.05. RESULTS: The average traction values obtained at the various levels were compared and there was no statistical significant difference. CONCLUSION: There is no variation in tension along the whole extension of the anterior rectus sheath.
publishDate 2010
dc.date.none.fl_str_mv 2010-08-01
2015-06-14T13:41:50Z
2015-06-14T13:41:50Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0102-86502010000400009
Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 25, n. 4, p. 347-349, 2010.
10.1590/S0102-86502010000400009
S0102-86502010000400009.pdf
0102-8650
S0102-86502010000400009
http://repositorio.unifesp.br/handle/11600/5886
WOS:000280607200008
url http://dx.doi.org/10.1590/S0102-86502010000400009
http://repositorio.unifesp.br/handle/11600/5886
identifier_str_mv Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 25, n. 4, p. 347-349, 2010.
10.1590/S0102-86502010000400009
S0102-86502010000400009.pdf
0102-8650
S0102-86502010000400009
WOS:000280607200008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Cirurgica Brasileira
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 347-349
application/pdf
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268283981922304