Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers

Detalhes bibliográficos
Autor(a) principal: Amorim, Carlos Roberto [UNIFESP]
Data de Publicação: 2007
Outros Autores: Nahas, Fabio Xerfan [UNIFESP], Souza, Virgínio Cândido Tosta de, Ely, Pedro Bins, Silveira, Romar Ângelo Barbato [UNIFESP], Novo, Neil Ferreira [UNIFESP], Ferreira, Lydia Masako [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0102-86502007000400005
http://repositorio.unifesp.br/handle/11600/3806
Resumo: PURPOSE: The aim of the present study was to assess, in cadavers, the resistance to medial traction of the posterior and anterior layer of the rectus abdominis muscle sheath. METHODS: An anatomical, prospective, self-controlled study was carried out in 20 male cadavers. An evaluation of the tension of the posterior and anterior layers of the rectus abdominis muscle sheath was performed following anatomical dissection of these structures. The traction necessary to advance the tissue ten millimeters was assessed using an analogic dynamometer. RESULTS: There was no significant statistical difference between the necessary traction at various levels of the anterior and posterior layers of the rectus sheath. However, medial advancement of the anterior layer of the rectus sheath required more traction strength than did advancement of the posterior layer to the midline. CONCLUSION: There is no difference in the tensile strength in the various levels of the anterior and posterior layers of the rectus sheath; however, medial advancement of the the anterior layer required more traction strength.
id UFSP_b97716b83bf19fd9bce6043c2a02cdee
oai_identifier_str oai:repositorio.unifesp.br/:11600/3806
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadaversTensão das bainhas anterior e posterior do músculo reto do abdome em cadáveresAbdominal musclesTensile strengthRectus abdominisCadáverMúsculos AbdominaisResistência à TraçãoReto do AbdomeCadáverPURPOSE: The aim of the present study was to assess, in cadavers, the resistance to medial traction of the posterior and anterior layer of the rectus abdominis muscle sheath. METHODS: An anatomical, prospective, self-controlled study was carried out in 20 male cadavers. An evaluation of the tension of the posterior and anterior layers of the rectus abdominis muscle sheath was performed following anatomical dissection of these structures. The traction necessary to advance the tissue ten millimeters was assessed using an analogic dynamometer. RESULTS: There was no significant statistical difference between the necessary traction at various levels of the anterior and posterior layers of the rectus sheath. However, medial advancement of the anterior layer of the rectus sheath required more traction strength than did advancement of the posterior layer to the midline. CONCLUSION: There is no difference in the tensile strength in the various levels of the anterior and posterior layers of the rectus sheath; however, medial advancement of the the anterior layer required more traction strength.OBJETIVO: Comparar a resistência à tração medial das lâminas posterior e anterior da bainha do músculo reto do abdome em diferentes níveis supra e infra-umbilicais em cadáveres. MÉTODOS: Vinte cadáveres adultos foram submetidos à dissecção da parede abdominal anterior. Foram feitas alças com fio de náilon no plano aponeurótico em oito pontos diferentes na lâmina anterior e na lâmina posterior da bainha do músculo reto do abdome, sendo quatro destes pontos supra-umbilicais e quatro infra-umbilicais. Com o uso de um dinamômetro analógico, foi verificada a força necessária para o avanço medial de dez milímetros destes dezesseis pontos. RESULTADOS: Não foram encontradas diferenças significantes de medidas da resistência à tração entre os diferentes níveis da aponeurose anterior e posterior, mas quando se comparou as medidas obtidas na aponeurose anterior às obtidas na posterior verificou-se que a aponeurose anterior necessitou de maior força de tração para o avanço medial. CONCLUSÃO: Não há diferença de tensão ao longo da aponeurose anterior e posterior. A aponeurose anterior é mais resistente à tração medial quando comparada à posterior.Federal University of São Paulo Postgraduate ProgramUniversidade Federal de São Paulo (UNIFESP) Department of Surgery Division of Plastic SurgeryUNIVÁS Department of Colon and Rectum SurgerySanta Casa Porto Alegre Plastic Surgery UnitUniversity Santo AmaroUNIFESP, Postgraduate ProgramUNIFESP, Department of Surgery Division of Plastic SurgerySciELOSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaUniversidade Federal de São Paulo (UNIFESP)UNIVÁS Department of Colon and Rectum SurgerySanta Casa Porto Alegre Plastic Surgery UnitUniversity Santo AmaroAmorim, Carlos Roberto [UNIFESP]Nahas, Fabio Xerfan [UNIFESP]Souza, Virgínio Cândido Tosta deEly, Pedro BinsSilveira, Romar Ângelo Barbato [UNIFESP]Novo, Neil Ferreira [UNIFESP]Ferreira, Lydia Masako [UNIFESP]2015-06-14T13:37:00Z2015-06-14T13:37:00Z2007-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion255-259application/pdfhttp://dx.doi.org/10.1590/S0102-86502007000400005Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 4, p. 255-259, 2007.10.1590/S0102-86502007000400005S0102-86502007000400005.pdf0102-8650S0102-86502007000400005http://repositorio.unifesp.br/handle/11600/3806WOS:000258573200005engActa Cirurgica Brasileirainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-07-29T20:11:22Zoai:repositorio.unifesp.br/:11600/3806Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-07-29T20:11:22Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
Tensão das bainhas anterior e posterior do músculo reto do abdome em cadáveres
title Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
spellingShingle Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
Amorim, Carlos Roberto [UNIFESP]
Abdominal muscles
Tensile strength
Rectus abdominis
Cadáver
Músculos Abdominais
Resistência à Tração
Reto do Abdome
Cadáver
title_short Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
title_full Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
title_fullStr Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
title_full_unstemmed Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
title_sort Tensile strength of the posterior and anterior layer of the rectus abdominis muscle sheath in cadavers
author Amorim, Carlos Roberto [UNIFESP]
author_facet Amorim, Carlos Roberto [UNIFESP]
Nahas, Fabio Xerfan [UNIFESP]
Souza, Virgínio Cândido Tosta de
Ely, Pedro Bins
Silveira, Romar Ângelo Barbato [UNIFESP]
Novo, Neil Ferreira [UNIFESP]
Ferreira, Lydia Masako [UNIFESP]
author_role author
author2 Nahas, Fabio Xerfan [UNIFESP]
Souza, Virgínio Cândido Tosta de
Ely, Pedro Bins
Silveira, Romar Ângelo Barbato [UNIFESP]
Novo, Neil Ferreira [UNIFESP]
Ferreira, Lydia Masako [UNIFESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
UNIVÁS Department of Colon and Rectum Surgery
Santa Casa Porto Alegre Plastic Surgery Unit
University Santo Amaro
dc.contributor.author.fl_str_mv Amorim, Carlos Roberto [UNIFESP]
Nahas, Fabio Xerfan [UNIFESP]
Souza, Virgínio Cândido Tosta de
Ely, Pedro Bins
Silveira, Romar Ângelo Barbato [UNIFESP]
Novo, Neil Ferreira [UNIFESP]
Ferreira, Lydia Masako [UNIFESP]
dc.subject.por.fl_str_mv Abdominal muscles
Tensile strength
Rectus abdominis
Cadáver
Músculos Abdominais
Resistência à Tração
Reto do Abdome
Cadáver
topic Abdominal muscles
Tensile strength
Rectus abdominis
Cadáver
Músculos Abdominais
Resistência à Tração
Reto do Abdome
Cadáver
description PURPOSE: The aim of the present study was to assess, in cadavers, the resistance to medial traction of the posterior and anterior layer of the rectus abdominis muscle sheath. METHODS: An anatomical, prospective, self-controlled study was carried out in 20 male cadavers. An evaluation of the tension of the posterior and anterior layers of the rectus abdominis muscle sheath was performed following anatomical dissection of these structures. The traction necessary to advance the tissue ten millimeters was assessed using an analogic dynamometer. RESULTS: There was no significant statistical difference between the necessary traction at various levels of the anterior and posterior layers of the rectus sheath. However, medial advancement of the anterior layer of the rectus sheath required more traction strength than did advancement of the posterior layer to the midline. CONCLUSION: There is no difference in the tensile strength in the various levels of the anterior and posterior layers of the rectus sheath; however, medial advancement of the the anterior layer required more traction strength.
publishDate 2007
dc.date.none.fl_str_mv 2007-08-01
2015-06-14T13:37:00Z
2015-06-14T13:37:00Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0102-86502007000400005
Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 4, p. 255-259, 2007.
10.1590/S0102-86502007000400005
S0102-86502007000400005.pdf
0102-8650
S0102-86502007000400005
http://repositorio.unifesp.br/handle/11600/3806
WOS:000258573200005
url http://dx.doi.org/10.1590/S0102-86502007000400005
http://repositorio.unifesp.br/handle/11600/3806
identifier_str_mv Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 4, p. 255-259, 2007.
10.1590/S0102-86502007000400005
S0102-86502007000400005.pdf
0102-8650
S0102-86502007000400005
WOS:000258573200005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Cirurgica Brasileira
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 255-259
application/pdf
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268276950171648