Ultrasonography for measuring rectus abdominis muscles diastasis

Detalhes bibliográficos
Autor(a) principal: Mendes,Denise de Almeida
Data de Publicação: 2007
Outros Autores: Nahas,Fábio Xerfan, Veiga,Daniela Francescato, Mendes,Fernando Vilela, Figueiras,Ricardo Góes, Gomes,Heitor Carvalho, Ely,Pedro Bins, Novo,Neil Ferreira, Ferreira,Lydia Masako
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Cirúrgica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300005
Resumo: PURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis. METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values. RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation. CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.
id SBDPC-1_b79d1a8649ae89ac79e1643fa43054d6
oai_identifier_str oai:scielo:S0102-86502007000300005
network_acronym_str SBDPC-1
network_name_str Acta Cirúrgica Brasileira (Online)
repository_id_str
spelling Ultrasonography for measuring rectus abdominis muscles diastasisAbdominal WallAbdominal MusclesUltrasonographyDiagnostic ImagingSurgery, PlasticRectus AbdominisPURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis. METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values. RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation. CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia2007-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300005Acta Cirúrgica Brasileira v.22 n.3 2007reponame:Acta Cirúrgica Brasileira (Online)instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)instacron:SBDPC10.1590/S0102-86502007000300005info:eu-repo/semantics/openAccessMendes,Denise de AlmeidaNahas,Fábio XerfanVeiga,Daniela FrancescatoMendes,Fernando VilelaFigueiras,Ricardo GóesGomes,Heitor CarvalhoEly,Pedro BinsNovo,Neil FerreiraFerreira,Lydia Masakoeng2007-05-24T00:00:00Zoai:scielo:S0102-86502007000300005Revistahttps://www.bvs-vet.org.br/vetindex/periodicos/acta-cirurgica-brasileira/https://old.scielo.br/oai/scielo-oai.php||sgolden@terra.com.br0102-86501678-2674opendoar:2007-05-24T00:00Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)false
dc.title.none.fl_str_mv Ultrasonography for measuring rectus abdominis muscles diastasis
title Ultrasonography for measuring rectus abdominis muscles diastasis
spellingShingle Ultrasonography for measuring rectus abdominis muscles diastasis
Mendes,Denise de Almeida
Abdominal Wall
Abdominal Muscles
Ultrasonography
Diagnostic Imaging
Surgery, Plastic
Rectus Abdominis
title_short Ultrasonography for measuring rectus abdominis muscles diastasis
title_full Ultrasonography for measuring rectus abdominis muscles diastasis
title_fullStr Ultrasonography for measuring rectus abdominis muscles diastasis
title_full_unstemmed Ultrasonography for measuring rectus abdominis muscles diastasis
title_sort Ultrasonography for measuring rectus abdominis muscles diastasis
author Mendes,Denise de Almeida
author_facet Mendes,Denise de Almeida
Nahas,Fábio Xerfan
Veiga,Daniela Francescato
Mendes,Fernando Vilela
Figueiras,Ricardo Góes
Gomes,Heitor Carvalho
Ely,Pedro Bins
Novo,Neil Ferreira
Ferreira,Lydia Masako
author_role author
author2 Nahas,Fábio Xerfan
Veiga,Daniela Francescato
Mendes,Fernando Vilela
Figueiras,Ricardo Góes
Gomes,Heitor Carvalho
Ely,Pedro Bins
Novo,Neil Ferreira
Ferreira,Lydia Masako
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Mendes,Denise de Almeida
Nahas,Fábio Xerfan
Veiga,Daniela Francescato
Mendes,Fernando Vilela
Figueiras,Ricardo Góes
Gomes,Heitor Carvalho
Ely,Pedro Bins
Novo,Neil Ferreira
Ferreira,Lydia Masako
dc.subject.por.fl_str_mv Abdominal Wall
Abdominal Muscles
Ultrasonography
Diagnostic Imaging
Surgery, Plastic
Rectus Abdominis
topic Abdominal Wall
Abdominal Muscles
Ultrasonography
Diagnostic Imaging
Surgery, Plastic
Rectus Abdominis
description PURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis. METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values. RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation. CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.
publishDate 2007
dc.date.none.fl_str_mv 2007-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300005
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502007000300005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0102-86502007000300005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv Acta Cirúrgica Brasileira v.22 n.3 2007
reponame:Acta Cirúrgica Brasileira (Online)
instname:Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron:SBDPC
instname_str Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
instacron_str SBDPC
institution SBDPC
reponame_str Acta Cirúrgica Brasileira (Online)
collection Acta Cirúrgica Brasileira (Online)
repository.name.fl_str_mv Acta Cirúrgica Brasileira (Online) - Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia (SBDPC)
repository.mail.fl_str_mv ||sgolden@terra.com.br
_version_ 1752126438640713728