Ultrasonography for measuring rectus abdominis muscles diastasis

Detalhes bibliográficos
Autor(a) principal: Mendes, Denise de Almeida [UNIFESP]
Data de Publicação: 2007
Outros Autores: Nahas, Fabio Xerfan [UNIFESP], Veiga, Daniela Francescato, Mendes, Fernando Vilela, Figueiras, Ricardo Góes, Gomes, Heitor Carvalho [UNIFESP], Ely, Pedro Bins, Novo, Neil Ferreira [UNIFESP], Ferreira, Lydia Masako [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0102-86502007000300005
http://repositorio.unifesp.br/handle/11600/3747
Resumo: PURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis. METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values. RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation. CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.
id UFSP_35720b9e6d2d61ea323f803b245d1229
oai_identifier_str oai:repositorio.unifesp.br/:11600/3747
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Ultrasonography for measuring rectus abdominis muscles diastasisUltra-sonografia para medir a diástase dos músculos retos do abdomeAbdominal WallAbdominal MusclesUltrasonographyDiagnostic ImagingSurgery, PlasticRectus AbdominisParede AbdominalMúsculos AbdominaisUltra-sonografiaDiagnóstico por ImagemCirurgia PlásticaReto do AbdomePURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis. METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values. RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation. CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.OBJETIVO: Estudos radiológicos pré-operatórios podem ser úteis para determinar a posição dos músculos retos do abdome antes de sua correção. O objetivo deste estudo é avaliar a acurácia da ultra-sonografia para medir a largura da diástase dos músculos retos do abdome. MÉTODOS: A diástase dos músculos retos foi medida pela ultra-sonografia, no pré-operatório em 20 mulheres. A diástase dos retos foi medida em sete níveis da bainha anterior dos retos foram examinados com ultra-som após inspiração profunda sustentada e após expiração. A diástase dos retos, nos mesmos níveis, foi também medida após sua exposição durante a abdominoplastia, por dois observadores independentes, usando compasso cirúrgico. As medidas foram comparadas usando o teste estatístico de Wilcoxon para dados não independentes. RESULTADOS: Não houve diferença significante entre as medidas ultra-sonográficas e intra-operatórias nos níveis supra-umbilicais e na cicatriz umbilical. Todavia, inferiormente à cicatriz umbilical, essas medidas diferiram significantemente sendo as ultra-sonográficas menores nestes pontos. CONCLUSÃO: A ultra-sonografia é um método acurado para medir a diástase de retos na região supra- umbilical e no nível do umbigo.Federal University of São PauloUNIVASUNIFESP Surgery Department Plastic Surgery DivisionUNIVAS Surgery Department Plastic Surgery DivisionMinas Center of Mastology and ImagingUNIVAS Surgery Department Plastic DivisionUNIFESPSanta Casa Plastic Surgery UnitUNIFESP Biostatistics DepartmentUNIFESP Plastic Surgery DivisionUNIFESP, Surgery Department Plastic Surgery DivisionUNIFESP, Biostatistics DepartmentUNIFESP, Plastic Surgery DivisionSciELOSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaUniversidade Federal de São Paulo (UNIFESP)UNIVASUNIVAS Surgery Department Plastic Surgery DivisionMinas Center of Mastology and ImagingUNIVAS Surgery Department Plastic DivisionSanta Casa Plastic Surgery UnitMendes, Denise de Almeida [UNIFESP]Nahas, Fabio Xerfan [UNIFESP]Veiga, Daniela FrancescatoMendes, Fernando VilelaFigueiras, Ricardo GóesGomes, Heitor Carvalho [UNIFESP]Ely, Pedro BinsNovo, Neil Ferreira [UNIFESP]Ferreira, Lydia Masako [UNIFESP]2015-06-14T13:36:57Z2015-06-14T13:36:57Z2007-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion182-186application/pdfhttp://dx.doi.org/10.1590/S0102-86502007000300005Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 3, p. 182-186, 2007.10.1590/S0102-86502007000300005S0102-86502007000300005.pdf0102-8650S0102-86502007000300005http://repositorio.unifesp.br/handle/11600/3747WOS:000258573100005engActa Cirurgica Brasileirainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-04T18:04:10Zoai:repositorio.unifesp.br/:11600/3747Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-04T18:04:10Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Ultrasonography for measuring rectus abdominis muscles diastasis
Ultra-sonografia para medir a diástase dos músculos retos do abdome
title Ultrasonography for measuring rectus abdominis muscles diastasis
spellingShingle Ultrasonography for measuring rectus abdominis muscles diastasis
Mendes, Denise de Almeida [UNIFESP]
Abdominal Wall
Abdominal Muscles
Ultrasonography
Diagnostic Imaging
Surgery, Plastic
Rectus Abdominis
Parede Abdominal
Músculos Abdominais
Ultra-sonografia
Diagnóstico por Imagem
Cirurgia Plástica
Reto do Abdome
title_short Ultrasonography for measuring rectus abdominis muscles diastasis
title_full Ultrasonography for measuring rectus abdominis muscles diastasis
title_fullStr Ultrasonography for measuring rectus abdominis muscles diastasis
title_full_unstemmed Ultrasonography for measuring rectus abdominis muscles diastasis
title_sort Ultrasonography for measuring rectus abdominis muscles diastasis
author Mendes, Denise de Almeida [UNIFESP]
author_facet Mendes, Denise de Almeida [UNIFESP]
Nahas, Fabio Xerfan [UNIFESP]
Veiga, Daniela Francescato
Mendes, Fernando Vilela
Figueiras, Ricardo Góes
Gomes, Heitor Carvalho [UNIFESP]
Ely, Pedro Bins
Novo, Neil Ferreira [UNIFESP]
Ferreira, Lydia Masako [UNIFESP]
author_role author
author2 Nahas, Fabio Xerfan [UNIFESP]
Veiga, Daniela Francescato
Mendes, Fernando Vilela
Figueiras, Ricardo Góes
Gomes, Heitor Carvalho [UNIFESP]
Ely, Pedro Bins
Novo, Neil Ferreira [UNIFESP]
Ferreira, Lydia Masako [UNIFESP]
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
UNIVAS
UNIVAS Surgery Department Plastic Surgery Division
Minas Center of Mastology and Imaging
UNIVAS Surgery Department Plastic Division
Santa Casa Plastic Surgery Unit
dc.contributor.author.fl_str_mv Mendes, Denise de Almeida [UNIFESP]
Nahas, Fabio Xerfan [UNIFESP]
Veiga, Daniela Francescato
Mendes, Fernando Vilela
Figueiras, Ricardo Góes
Gomes, Heitor Carvalho [UNIFESP]
Ely, Pedro Bins
Novo, Neil Ferreira [UNIFESP]
Ferreira, Lydia Masako [UNIFESP]
dc.subject.por.fl_str_mv Abdominal Wall
Abdominal Muscles
Ultrasonography
Diagnostic Imaging
Surgery, Plastic
Rectus Abdominis
Parede Abdominal
Músculos Abdominais
Ultra-sonografia
Diagnóstico por Imagem
Cirurgia Plástica
Reto do Abdome
topic Abdominal Wall
Abdominal Muscles
Ultrasonography
Diagnostic Imaging
Surgery, Plastic
Rectus Abdominis
Parede Abdominal
Músculos Abdominais
Ultra-sonografia
Diagnóstico por Imagem
Cirurgia Plástica
Reto do Abdome
description PURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis. METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values. RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation. CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level.
publishDate 2007
dc.date.none.fl_str_mv 2007-06-01
2015-06-14T13:36:57Z
2015-06-14T13:36:57Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0102-86502007000300005
Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 3, p. 182-186, 2007.
10.1590/S0102-86502007000300005
S0102-86502007000300005.pdf
0102-8650
S0102-86502007000300005
http://repositorio.unifesp.br/handle/11600/3747
WOS:000258573100005
url http://dx.doi.org/10.1590/S0102-86502007000300005
http://repositorio.unifesp.br/handle/11600/3747
identifier_str_mv Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 3, p. 182-186, 2007.
10.1590/S0102-86502007000300005
S0102-86502007000300005.pdf
0102-8650
S0102-86502007000300005
WOS:000258573100005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Cirurgica Brasileira
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 182-186
application/pdf
dc.publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publisher.none.fl_str_mv Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268381332766720