The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength

Detalhes bibliográficos
Autor(a) principal: Pinheiro,Rômulo Pedroza
Data de Publicação: 2022
Outros Autores: Miranda,Raffaello de Freitas, Shimano,Antonio Carlos, Chandanson,Thibault, George,Keri, Defino,Helton L.A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Ortopedia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327
Resumo: Abstract Objective We aimed to study the “in vitro” pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw, SpineGuard Inc, Boulder, Colorado, USA), a screw designed to be inserted using a direct insertion technique. Methods Dynamic Surgical Guidance Screws of 5.5 and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared with lineto-line tapping. Conclusion Dynamic Surgical Guidance Screw showed the highest pullout strength after its insertion without pilot hole and tapping.
id SBOT-2_eee84626b9a8602fc5c5e691ce71f8c8
oai_identifier_str oai:scielo:S0102-36162022000200327
network_acronym_str SBOT-2
network_name_str Revista Brasileira de Ortopedia (Online)
repository_id_str
spelling The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strengthspinal fusionpedicle screwbone screwsbiomechanical phenomena/ physiologyAbstract Objective We aimed to study the “in vitro” pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw, SpineGuard Inc, Boulder, Colorado, USA), a screw designed to be inserted using a direct insertion technique. Methods Dynamic Surgical Guidance Screws of 5.5 and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared with lineto-line tapping. Conclusion Dynamic Surgical Guidance Screw showed the highest pullout strength after its insertion without pilot hole and tapping.Sociedade Brasileira de Ortopedia e Traumatologia2022-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327Revista Brasileira de Ortopedia v.57 n.2 2022reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1055/s-0041-1732390info:eu-repo/semantics/openAccessPinheiro,Rômulo PedrozaMiranda,Raffaello de FreitasShimano,Antonio CarlosChandanson,ThibaultGeorge,KeriDefino,Helton L.A.eng2022-07-04T00:00:00Zoai:scielo:S0102-36162022000200327Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2022-07-04T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false
dc.title.none.fl_str_mv The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
title The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
spellingShingle The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
Pinheiro,Rômulo Pedroza
spinal fusion
pedicle screw
bone screws
biomechanical phenomena/ physiology
title_short The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
title_full The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
title_fullStr The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
title_full_unstemmed The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
title_sort The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
author Pinheiro,Rômulo Pedroza
author_facet Pinheiro,Rômulo Pedroza
Miranda,Raffaello de Freitas
Shimano,Antonio Carlos
Chandanson,Thibault
George,Keri
Defino,Helton L.A.
author_role author
author2 Miranda,Raffaello de Freitas
Shimano,Antonio Carlos
Chandanson,Thibault
George,Keri
Defino,Helton L.A.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Pinheiro,Rômulo Pedroza
Miranda,Raffaello de Freitas
Shimano,Antonio Carlos
Chandanson,Thibault
George,Keri
Defino,Helton L.A.
dc.subject.por.fl_str_mv spinal fusion
pedicle screw
bone screws
biomechanical phenomena/ physiology
topic spinal fusion
pedicle screw
bone screws
biomechanical phenomena/ physiology
description Abstract Objective We aimed to study the “in vitro” pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw, SpineGuard Inc, Boulder, Colorado, USA), a screw designed to be inserted using a direct insertion technique. Methods Dynamic Surgical Guidance Screws of 5.5 and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared with lineto-line tapping. Conclusion Dynamic Surgical Guidance Screw showed the highest pullout strength after its insertion without pilot hole and tapping.
publishDate 2022
dc.date.none.fl_str_mv 2022-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1055/s-0041-1732390
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
publisher.none.fl_str_mv Sociedade Brasileira de Ortopedia e Traumatologia
dc.source.none.fl_str_mv Revista Brasileira de Ortopedia v.57 n.2 2022
reponame:Revista Brasileira de Ortopedia (Online)
instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron:SBOT
instname_str Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
instacron_str SBOT
institution SBOT
reponame_str Revista Brasileira de Ortopedia (Online)
collection Revista Brasileira de Ortopedia (Online)
repository.name.fl_str_mv Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)
repository.mail.fl_str_mv ||rbo@sbot.org.br
_version_ 1752122363325972480