The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Ortopedia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327 |
Resumo: | Abstract Objective We aimed to study the “in vitro” pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw, SpineGuard Inc, Boulder, Colorado, USA), a screw designed to be inserted using a direct insertion technique. Methods Dynamic Surgical Guidance Screws of 5.5 and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared with lineto-line tapping. Conclusion Dynamic Surgical Guidance Screw showed the highest pullout strength after its insertion without pilot hole and tapping. |
id |
SBOT-2_eee84626b9a8602fc5c5e691ce71f8c8 |
---|---|
oai_identifier_str |
oai:scielo:S0102-36162022000200327 |
network_acronym_str |
SBOT-2 |
network_name_str |
Revista Brasileira de Ortopedia (Online) |
repository_id_str |
|
spelling |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strengthspinal fusionpedicle screwbone screwsbiomechanical phenomena/ physiologyAbstract Objective We aimed to study the “in vitro” pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw, SpineGuard Inc, Boulder, Colorado, USA), a screw designed to be inserted using a direct insertion technique. Methods Dynamic Surgical Guidance Screws of 5.5 and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared with lineto-line tapping. Conclusion Dynamic Surgical Guidance Screw showed the highest pullout strength after its insertion without pilot hole and tapping.Sociedade Brasileira de Ortopedia e Traumatologia2022-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327Revista Brasileira de Ortopedia v.57 n.2 2022reponame:Revista Brasileira de Ortopedia (Online)instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)instacron:SBOT10.1055/s-0041-1732390info:eu-repo/semantics/openAccessPinheiro,Rômulo PedrozaMiranda,Raffaello de FreitasShimano,Antonio CarlosChandanson,ThibaultGeorge,KeriDefino,Helton L.A.eng2022-07-04T00:00:00Zoai:scielo:S0102-36162022000200327Revistahttp://www.rbo.org.br/https://old.scielo.br/oai/scielo-oai.php||rbo@sbot.org.br1982-43780102-3616opendoar:2022-07-04T00:00Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT)false |
dc.title.none.fl_str_mv |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength |
title |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength |
spellingShingle |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength Pinheiro,Rômulo Pedroza spinal fusion pedicle screw bone screws biomechanical phenomena/ physiology |
title_short |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength |
title_full |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength |
title_fullStr |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength |
title_full_unstemmed |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength |
title_sort |
The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength |
author |
Pinheiro,Rômulo Pedroza |
author_facet |
Pinheiro,Rômulo Pedroza Miranda,Raffaello de Freitas Shimano,Antonio Carlos Chandanson,Thibault George,Keri Defino,Helton L.A. |
author_role |
author |
author2 |
Miranda,Raffaello de Freitas Shimano,Antonio Carlos Chandanson,Thibault George,Keri Defino,Helton L.A. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Pinheiro,Rômulo Pedroza Miranda,Raffaello de Freitas Shimano,Antonio Carlos Chandanson,Thibault George,Keri Defino,Helton L.A. |
dc.subject.por.fl_str_mv |
spinal fusion pedicle screw bone screws biomechanical phenomena/ physiology |
topic |
spinal fusion pedicle screw bone screws biomechanical phenomena/ physiology |
description |
Abstract Objective We aimed to study the “in vitro” pullout strength of SpineGuard/Zavation Dynamic Surgical Guidance Z-Direct Screw (DSG Screw, SpineGuard Inc, Boulder, Colorado, USA), a screw designed to be inserted using a direct insertion technique. Methods Dynamic Surgical Guidance Screws of 5.5 and 6.5 mm were introduced into polyurethane blocks with a density of 10 PCF (0,16g/cm3). According to the experimental group, screws were inserted without pilot hole, with pilot without tapping, undertapping and line-to-line tapping. Screw pullout tests were performed using a universal test machine after screw insertion into polyurethane blocks. Results Screws inserted directly into the polyurethane blocks without pilot hole and tapping showed a statistically higher pullout strength. Insertion of the screw without tapping or with undertapping increases the pullout screw strength compared with lineto-line tapping. Conclusion Dynamic Surgical Guidance Screw showed the highest pullout strength after its insertion without pilot hole and tapping. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162022000200327 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0041-1732390 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Ortopedia e Traumatologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Ortopedia v.57 n.2 2022 reponame:Revista Brasileira de Ortopedia (Online) instname:Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) instacron:SBOT |
instname_str |
Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
instacron_str |
SBOT |
institution |
SBOT |
reponame_str |
Revista Brasileira de Ortopedia (Online) |
collection |
Revista Brasileira de Ortopedia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Ortopedia (Online) - Sociedade Brasileira de Ortopedia e Traumatologia (SBOT) |
repository.mail.fl_str_mv |
||rbo@sbot.org.br |
_version_ |
1752122363325972480 |