Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)

Detalhes bibliográficos
Autor(a) principal: Correia,Rodolfo P.
Data de Publicação: 2015
Outros Autores: Bortolucci,Ana Carolina A., Lopes,Annelise C. W., Sandes,Alex F., Azambuja,Ana Paula de, Viana,Marta A., Sales,Maria M., Yamamoto,Mihoko, Bacal,Nydia S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442015000600389
Resumo: ABSTRACT The Brazilian Group of Flow Cytometry (Grupo Brasileiro de Citometria de Fluxo [GBCFLUX]), founded on April 24, 2010, is composed of experts in flow cytometry (FC) area who have the common objective of contributing to technical and scientific advances in Brazilian clinical and research laboratories. Among GBCFLUX working groups, the Quality Control (QC) subcommittee is responsible for discussing data in the literature and contributes to the quality assurance of the pre-analytical, analytical and post-analytical process in FC. The QC subcommittee's actions began through meetings and lectures, in which data from the literature were reviewed and discussed with all participating members of the GBCFLUX. In a second step, it was decided to draw up a text of technical and scientific consensus recommendations, informative and educative, for dissemination to all FC working groups in Brazil. To this effect, a questionnaire with objective responses was designed and sent to 35 recognized Brazilian institutions, in order to evaluate the QC profile of these institutions. Thus, the QC technical-scientific recommendations, which will be described in this updating article, are intended to ensure the process quality, technical standardization, and reproducibility of results in FC.
id SBP-1_977441703942a21025ec606390c2dc7a
oai_identifier_str oai:scielo:S1676-24442015000600389
network_acronym_str SBP-1
network_name_str Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
repository_id_str
spelling Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)flow cytometryquality controlABSTRACT The Brazilian Group of Flow Cytometry (Grupo Brasileiro de Citometria de Fluxo [GBCFLUX]), founded on April 24, 2010, is composed of experts in flow cytometry (FC) area who have the common objective of contributing to technical and scientific advances in Brazilian clinical and research laboratories. Among GBCFLUX working groups, the Quality Control (QC) subcommittee is responsible for discussing data in the literature and contributes to the quality assurance of the pre-analytical, analytical and post-analytical process in FC. The QC subcommittee's actions began through meetings and lectures, in which data from the literature were reviewed and discussed with all participating members of the GBCFLUX. In a second step, it was decided to draw up a text of technical and scientific consensus recommendations, informative and educative, for dissemination to all FC working groups in Brazil. To this effect, a questionnaire with objective responses was designed and sent to 35 recognized Brazilian institutions, in order to evaluate the QC profile of these institutions. Thus, the QC technical-scientific recommendations, which will be described in this updating article, are intended to ensure the process quality, technical standardization, and reproducibility of results in FC.Sociedade Brasileira de Patologia Clínica2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442015000600389Jornal Brasileiro de Patologia e Medicina Laboratorial v.51 n.6 2015reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)instname:Sociedade Brasileira de Patologia (SBP)instacron:SBP10.5935/1676-2444.20150061info:eu-repo/semantics/openAccessCorreia,Rodolfo P.Bortolucci,Ana Carolina A.Lopes,Annelise C. W.Sandes,Alex F.Azambuja,Ana Paula deViana,Marta A.Sales,Maria M.Yamamoto,MihokoBacal,Nydia S.eng2015-12-03T00:00:00Zoai:scielo:S1676-24442015000600389Revistahttp://www.scielo.br/jbpmlhttps://old.scielo.br/oai/scielo-oai.php||jbpml@sbpc.org.br1678-47741676-2444opendoar:2015-12-03T00:00Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)false
dc.title.none.fl_str_mv Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
title Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
spellingShingle Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
Correia,Rodolfo P.
flow cytometry
quality control
title_short Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
title_full Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
title_fullStr Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
title_full_unstemmed Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
title_sort Recommendations for quality assurance in multiparametric flow cytometry: first consensus of the Brazilian Group of Flow Cytometry (GBCFLUX)
author Correia,Rodolfo P.
author_facet Correia,Rodolfo P.
Bortolucci,Ana Carolina A.
Lopes,Annelise C. W.
Sandes,Alex F.
Azambuja,Ana Paula de
Viana,Marta A.
Sales,Maria M.
Yamamoto,Mihoko
Bacal,Nydia S.
author_role author
author2 Bortolucci,Ana Carolina A.
Lopes,Annelise C. W.
Sandes,Alex F.
Azambuja,Ana Paula de
Viana,Marta A.
Sales,Maria M.
Yamamoto,Mihoko
Bacal,Nydia S.
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Correia,Rodolfo P.
Bortolucci,Ana Carolina A.
Lopes,Annelise C. W.
Sandes,Alex F.
Azambuja,Ana Paula de
Viana,Marta A.
Sales,Maria M.
Yamamoto,Mihoko
Bacal,Nydia S.
dc.subject.por.fl_str_mv flow cytometry
quality control
topic flow cytometry
quality control
description ABSTRACT The Brazilian Group of Flow Cytometry (Grupo Brasileiro de Citometria de Fluxo [GBCFLUX]), founded on April 24, 2010, is composed of experts in flow cytometry (FC) area who have the common objective of contributing to technical and scientific advances in Brazilian clinical and research laboratories. Among GBCFLUX working groups, the Quality Control (QC) subcommittee is responsible for discussing data in the literature and contributes to the quality assurance of the pre-analytical, analytical and post-analytical process in FC. The QC subcommittee's actions began through meetings and lectures, in which data from the literature were reviewed and discussed with all participating members of the GBCFLUX. In a second step, it was decided to draw up a text of technical and scientific consensus recommendations, informative and educative, for dissemination to all FC working groups in Brazil. To this effect, a questionnaire with objective responses was designed and sent to 35 recognized Brazilian institutions, in order to evaluate the QC profile of these institutions. Thus, the QC technical-scientific recommendations, which will be described in this updating article, are intended to ensure the process quality, technical standardization, and reproducibility of results in FC.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442015000600389
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1676-24442015000600389
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/1676-2444.20150061
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv
Sociedade Brasileira de Patologia Clínica
publisher.none.fl_str_mv
Sociedade Brasileira de Patologia Clínica
dc.source.none.fl_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial v.51 n.6 2015
reponame:Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
instname:Sociedade Brasileira de Patologia (SBP)
instacron:SBP
instname_str Sociedade Brasileira de Patologia (SBP)
instacron_str SBP
institution SBP
reponame_str Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
collection Jornal Brasileiro de Patologia e Medicina Laboratorial (Online)
repository.name.fl_str_mv Jornal Brasileiro de Patologia e Medicina Laboratorial (Online) - Sociedade Brasileira de Patologia (SBP)
repository.mail.fl_str_mv ||jbpml@sbpc.org.br
_version_ 1752122296340840448