A fast fluorimetric flow injection method to determine ibuprofen
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000700033 |
Resumo: | The native fluorescence of ibuprofen was enhanced when a host-guest complex of the analyte with beta cyclodextrin (beta-CD) was formed. So, based on this fact, a flow injection method to determine ibuprofen in different pharmaceutical preparations with fluorescence detection (lambdaem 287 nm, lambdaexc 223 nm) was developed. The calibration curve was linear over the range 6.00 - 60.0 mg L-1 of ibuprofen and the detection limit (LOD) for S/N=3 was 4.5 mg L-1. The relative standard deviation was 1.2% and the sample throughput 240 h-1. The method was validated by comparing the proposed and the official method to commercial preparation samples. |
id |
SBQ-2_4e642a2efa73e08f5f31b989a98d8226 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532006000700033 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
A fast fluorimetric flow injection method to determine ibuprofenibuprofenFIAspectrofluorimetrypharmaceutical preparationThe native fluorescence of ibuprofen was enhanced when a host-guest complex of the analyte with beta cyclodextrin (beta-CD) was formed. So, based on this fact, a flow injection method to determine ibuprofen in different pharmaceutical preparations with fluorescence detection (lambdaem 287 nm, lambdaexc 223 nm) was developed. The calibration curve was linear over the range 6.00 - 60.0 mg L-1 of ibuprofen and the detection limit (LOD) for S/N=3 was 4.5 mg L-1. The relative standard deviation was 1.2% and the sample throughput 240 h-1. The method was validated by comparing the proposed and the official method to commercial preparation samples.Sociedade Brasileira de Química2006-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000700033Journal of the Brazilian Chemical Society v.17 n.7 2006reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532006000700033info:eu-repo/semantics/openAccessLista,Adriana G.Palomeque,Miriam E.Band,Beatriz S. Fernándezeng2007-01-29T00:00:00Zoai:scielo:S0103-50532006000700033Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2007-01-29T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
A fast fluorimetric flow injection method to determine ibuprofen |
title |
A fast fluorimetric flow injection method to determine ibuprofen |
spellingShingle |
A fast fluorimetric flow injection method to determine ibuprofen Lista,Adriana G. ibuprofen FIA spectrofluorimetry pharmaceutical preparation |
title_short |
A fast fluorimetric flow injection method to determine ibuprofen |
title_full |
A fast fluorimetric flow injection method to determine ibuprofen |
title_fullStr |
A fast fluorimetric flow injection method to determine ibuprofen |
title_full_unstemmed |
A fast fluorimetric flow injection method to determine ibuprofen |
title_sort |
A fast fluorimetric flow injection method to determine ibuprofen |
author |
Lista,Adriana G. |
author_facet |
Lista,Adriana G. Palomeque,Miriam E. Band,Beatriz S. Fernández |
author_role |
author |
author2 |
Palomeque,Miriam E. Band,Beatriz S. Fernández |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Lista,Adriana G. Palomeque,Miriam E. Band,Beatriz S. Fernández |
dc.subject.por.fl_str_mv |
ibuprofen FIA spectrofluorimetry pharmaceutical preparation |
topic |
ibuprofen FIA spectrofluorimetry pharmaceutical preparation |
description |
The native fluorescence of ibuprofen was enhanced when a host-guest complex of the analyte with beta cyclodextrin (beta-CD) was formed. So, based on this fact, a flow injection method to determine ibuprofen in different pharmaceutical preparations with fluorescence detection (lambdaem 287 nm, lambdaexc 223 nm) was developed. The calibration curve was linear over the range 6.00 - 60.0 mg L-1 of ibuprofen and the detection limit (LOD) for S/N=3 was 4.5 mg L-1. The relative standard deviation was 1.2% and the sample throughput 240 h-1. The method was validated by comparing the proposed and the official method to commercial preparation samples. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000700033 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532006000700033 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532006000700033 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.17 n.7 2006 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318167442325504 |