Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800006 |
Resumo: | A method for the simultaneous quantification of lycopene, β-carotene, retinol and α-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at -20°C for three months for stability study. The methodology was applied to samples from painters and individuals not exposed to paints (n = 75). The assay was linear for all vitamins (r > 0.99). Intra- and inter-run precisions were obtained with coefficient of variation smaller than 5%. The accuracies ranged from 0.29 to -5.80% and recoveries between 92.73 and 101.97%. Plasma samples and extracted supernatants were stable for 60 days at -20°C. A significant decrease of lycopene, β-carotene and retinol concentrations in plasma from exposed individuals compared to non-exposed individuals (p < 0.05) was observed. The method is simple, reproducible, precise, accurate and sensitive, and can be routinely utilized in clinical laboratories. |
id |
SBQ-2_f9992734c85f304d95d02c7a383ff4fc |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532012000800006 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteersretinolα-tocopherollycopeneβ-caroteneHPLCliquid-liquid extractionA method for the simultaneous quantification of lycopene, β-carotene, retinol and α-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at -20°C for three months for stability study. The methodology was applied to samples from painters and individuals not exposed to paints (n = 75). The assay was linear for all vitamins (r > 0.99). Intra- and inter-run precisions were obtained with coefficient of variation smaller than 5%. The accuracies ranged from 0.29 to -5.80% and recoveries between 92.73 and 101.97%. Plasma samples and extracted supernatants were stable for 60 days at -20°C. A significant decrease of lycopene, β-carotene and retinol concentrations in plasma from exposed individuals compared to non-exposed individuals (p < 0.05) was observed. The method is simple, reproducible, precise, accurate and sensitive, and can be routinely utilized in clinical laboratories.Sociedade Brasileira de Química2012-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800006Journal of the Brazilian Chemical Society v.23 n.8 2012reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532012005000001info:eu-repo/semantics/openAccessCharão,Mariele F.Moro,Angela M.Brucker,NatáliaBulcão,Rachel P.Baierle,MaríliaFreitas,FernandoDurgante,JulianoNascimento,SabrinaBubols,Guilherme B.Saldiva,Paulo H.Bohrer,DeniseGarcia,Solange C.eng2012-09-14T00:00:00Zoai:scielo:S0103-50532012000800006Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2012-09-14T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers |
title |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers |
spellingShingle |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers Charão,Mariele F. retinol α-tocopherol lycopene β-carotene HPLC liquid-liquid extraction |
title_short |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers |
title_full |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers |
title_fullStr |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers |
title_full_unstemmed |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers |
title_sort |
Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers |
author |
Charão,Mariele F. |
author_facet |
Charão,Mariele F. Moro,Angela M. Brucker,Natália Bulcão,Rachel P. Baierle,Marília Freitas,Fernando Durgante,Juliano Nascimento,Sabrina Bubols,Guilherme B. Saldiva,Paulo H. Bohrer,Denise Garcia,Solange C. |
author_role |
author |
author2 |
Moro,Angela M. Brucker,Natália Bulcão,Rachel P. Baierle,Marília Freitas,Fernando Durgante,Juliano Nascimento,Sabrina Bubols,Guilherme B. Saldiva,Paulo H. Bohrer,Denise Garcia,Solange C. |
author2_role |
author author author author author author author author author author author |
dc.contributor.author.fl_str_mv |
Charão,Mariele F. Moro,Angela M. Brucker,Natália Bulcão,Rachel P. Baierle,Marília Freitas,Fernando Durgante,Juliano Nascimento,Sabrina Bubols,Guilherme B. Saldiva,Paulo H. Bohrer,Denise Garcia,Solange C. |
dc.subject.por.fl_str_mv |
retinol α-tocopherol lycopene β-carotene HPLC liquid-liquid extraction |
topic |
retinol α-tocopherol lycopene β-carotene HPLC liquid-liquid extraction |
description |
A method for the simultaneous quantification of lycopene, β-carotene, retinol and α-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at -20°C for three months for stability study. The methodology was applied to samples from painters and individuals not exposed to paints (n = 75). The assay was linear for all vitamins (r > 0.99). Intra- and inter-run precisions were obtained with coefficient of variation smaller than 5%. The accuracies ranged from 0.29 to -5.80% and recoveries between 92.73 and 101.97%. Plasma samples and extracted supernatants were stable for 60 days at -20°C. A significant decrease of lycopene, β-carotene and retinol concentrations in plasma from exposed individuals compared to non-exposed individuals (p < 0.05) was observed. The method is simple, reproducible, precise, accurate and sensitive, and can be routinely utilized in clinical laboratories. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800006 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800006 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532012005000001 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.23 n.8 2012 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318174030528512 |