Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000800020 |
Resumo: | This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals. |
id |
SBQ-3_116b246e0659b42decae971c48eb4a57 |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422013000800020 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatographybeta-lactam antibioticsHPLCmethod validationThis work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.Sociedade Brasileira de Química2013-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000800020Química Nova v.36 n.8 2013reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422013000800020info:eu-repo/semantics/openAccessMiguel,Gabriela CoelhoOrlando,Eduardo AdilsonSimionato,Ana Valéria Colnaghieng2013-10-04T00:00:00Zoai:scielo:S0100-40422013000800020Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2013-10-04T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography |
title |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography |
spellingShingle |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography Miguel,Gabriela Coelho beta-lactam antibiotics HPLC method validation |
title_short |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography |
title_full |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography |
title_fullStr |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography |
title_full_unstemmed |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography |
title_sort |
Quantification of beta-lactam antibiotics in veterinary drugs: amoxicillin and ampicillin determination by high performance liquid chromatography |
author |
Miguel,Gabriela Coelho |
author_facet |
Miguel,Gabriela Coelho Orlando,Eduardo Adilson Simionato,Ana Valéria Colnaghi |
author_role |
author |
author2 |
Orlando,Eduardo Adilson Simionato,Ana Valéria Colnaghi |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Miguel,Gabriela Coelho Orlando,Eduardo Adilson Simionato,Ana Valéria Colnaghi |
dc.subject.por.fl_str_mv |
beta-lactam antibiotics HPLC method validation |
topic |
beta-lactam antibiotics HPLC method validation |
description |
This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000800020 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000800020 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-40422013000800020 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.36 n.8 2013 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318115124674560 |