Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010 |
Resumo: | A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory. |
id |
SBQ-3_a12fbaf725f564e7bf72d55c878a808a |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422013000300010 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tabletsdissolutionprimaquinematrix tabletsA simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.Sociedade Brasileira de Química2013-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010Química Nova v.36 n.3 2013reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422013000300010info:eu-repo/semantics/openAccessCruz,Ariane P.Bertol,Charise D.Murakami,Fábio S.Pereira,Rafael N.Valente,Bruno R.Silva,Marcos A. S.Koester,Letícia S.eng2013-04-11T00:00:00Zoai:scielo:S0100-40422013000300010Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2013-04-11T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets |
title |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets |
spellingShingle |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets Cruz,Ariane P. dissolution primaquine matrix tablets |
title_short |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets |
title_full |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets |
title_fullStr |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets |
title_full_unstemmed |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets |
title_sort |
Development and validation of a dissolution test for primaquine/polyethylene oxide matrix tablets |
author |
Cruz,Ariane P. |
author_facet |
Cruz,Ariane P. Bertol,Charise D. Murakami,Fábio S. Pereira,Rafael N. Valente,Bruno R. Silva,Marcos A. S. Koester,Letícia S. |
author_role |
author |
author2 |
Bertol,Charise D. Murakami,Fábio S. Pereira,Rafael N. Valente,Bruno R. Silva,Marcos A. S. Koester,Letícia S. |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Cruz,Ariane P. Bertol,Charise D. Murakami,Fábio S. Pereira,Rafael N. Valente,Bruno R. Silva,Marcos A. S. Koester,Letícia S. |
dc.subject.por.fl_str_mv |
dissolution primaquine matrix tablets |
topic |
dissolution primaquine matrix tablets |
description |
A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000300010 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-40422013000300010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.36 n.3 2013 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318114685321216 |