Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628

Detalhes bibliográficos
Autor(a) principal: Fia, Ronaldo
Data de Publicação: 2013
Outros Autores: Matos, Antonio Teixeira de, Resende Luiz Fia, Fátima
Tipo de documento: Artigo
Idioma: por
eng
Título da fonte: Acta scientiarum. Technology (Online)
Texto Completo: http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/13628
Resumo: Three treatment systems consisting of anaerobic filters with upward flow followed by constructed wetland systems (CW) were evaluated for the removal of nutrients and phenolic compounds, in the treatment of coffee processing wastewater (WCP) in Viçosa, Minas Gerais State. Filters were made of PVC (1.5 m high and 0.35 m diameter) filled with gravel # 2 and CW were made of wooden boxes (1.5 m long, 0.4 m high and 0.5 m wide) sealed by HDPE geomembrane and filled with gravel ‘zero’. The WCP had the pH adjusted with lime to values close to 7.0 and the nutrient concentration changed to obtain a BOD/N/P ratio of 100/5/1. As a result, hydraulic retention times longer than 160 h in all treatment systems during phase III had not promoted greater efficiencies for removal compared with the phase I, because the recovery time of the systems was inadequate. The F1+CW1 system that received the lowest organic load, showed a satisfactory performance with regard to the removal of nutrients (above 50%).  
id UEM-6_9a3fc699f42c4d3afb6ed0875a22b9d3
oai_identifier_str oai:periodicos.uem.br/ojs:article/13628
network_acronym_str UEM-6
network_name_str Acta scientiarum. Technology (Online)
repository_id_str
spelling Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628anaerobic reactorconstructed wetland systemsphenolsnitrogenphosphoruscoffeeEngenharia AgrícolaThree treatment systems consisting of anaerobic filters with upward flow followed by constructed wetland systems (CW) were evaluated for the removal of nutrients and phenolic compounds, in the treatment of coffee processing wastewater (WCP) in Viçosa, Minas Gerais State. Filters were made of PVC (1.5 m high and 0.35 m diameter) filled with gravel # 2 and CW were made of wooden boxes (1.5 m long, 0.4 m high and 0.5 m wide) sealed by HDPE geomembrane and filled with gravel ‘zero’. The WCP had the pH adjusted with lime to values close to 7.0 and the nutrient concentration changed to obtain a BOD/N/P ratio of 100/5/1. As a result, hydraulic retention times longer than 160 h in all treatment systems during phase III had not promoted greater efficiencies for removal compared with the phase I, because the recovery time of the systems was inadequate. The F1+CW1 system that received the lowest organic load, showed a satisfactory performance with regard to the removal of nutrients (above 50%).  Universidade Estadual De Maringá2013-02-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/1362810.4025/actascitechnol.v35i3.13628Acta Scientiarum. Technology; Vol 35 No 3 (2013); 451-456Acta Scientiarum. Technology; v. 35 n. 3 (2013); 451-4561806-25631807-8664reponame:Acta scientiarum. Technology (Online)instname:Universidade Estadual de Maringá (UEM)instacron:UEMporenghttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/13628/pdfhttp://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/13628/pdf_1Fia, RonaldoMatos, Antonio Teixeira deResende Luiz Fia, Fátimainfo:eu-repo/semantics/openAccess2024-05-17T13:03:24Zoai:periodicos.uem.br/ojs:article/13628Revistahttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/indexPUBhttps://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/oai||actatech@uem.br1807-86641806-2563opendoar:2024-05-17T13:03:24Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)false
dc.title.none.fl_str_mv Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
title Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
spellingShingle Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
Fia, Ronaldo
anaerobic reactor
constructed wetland systems
phenols
nitrogen
phosphorus
coffee
Engenharia Agrícola
title_short Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
title_full Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
title_fullStr Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
title_full_unstemmed Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
title_sort Biological systems combined for the treatment of coffee processing wastewater: II - Removal of nutrients and phenolic compounds - doi: 10.4025/actascitechnol.v35i3.13628
author Fia, Ronaldo
author_facet Fia, Ronaldo
Matos, Antonio Teixeira de
Resende Luiz Fia, Fátima
author_role author
author2 Matos, Antonio Teixeira de
Resende Luiz Fia, Fátima
author2_role author
author
dc.contributor.author.fl_str_mv Fia, Ronaldo
Matos, Antonio Teixeira de
Resende Luiz Fia, Fátima
dc.subject.por.fl_str_mv anaerobic reactor
constructed wetland systems
phenols
nitrogen
phosphorus
coffee
Engenharia Agrícola
topic anaerobic reactor
constructed wetland systems
phenols
nitrogen
phosphorus
coffee
Engenharia Agrícola
description Three treatment systems consisting of anaerobic filters with upward flow followed by constructed wetland systems (CW) were evaluated for the removal of nutrients and phenolic compounds, in the treatment of coffee processing wastewater (WCP) in Viçosa, Minas Gerais State. Filters were made of PVC (1.5 m high and 0.35 m diameter) filled with gravel # 2 and CW were made of wooden boxes (1.5 m long, 0.4 m high and 0.5 m wide) sealed by HDPE geomembrane and filled with gravel ‘zero’. The WCP had the pH adjusted with lime to values close to 7.0 and the nutrient concentration changed to obtain a BOD/N/P ratio of 100/5/1. As a result, hydraulic retention times longer than 160 h in all treatment systems during phase III had not promoted greater efficiencies for removal compared with the phase I, because the recovery time of the systems was inadequate. The F1+CW1 system that received the lowest organic load, showed a satisfactory performance with regard to the removal of nutrients (above 50%).  
publishDate 2013
dc.date.none.fl_str_mv 2013-02-27
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/13628
10.4025/actascitechnol.v35i3.13628
url http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/13628
identifier_str_mv 10.4025/actascitechnol.v35i3.13628
dc.language.iso.fl_str_mv por
eng
language por
eng
dc.relation.none.fl_str_mv http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/13628/pdf
http://www.periodicos.uem.br/ojs/index.php/ActaSciTechnol/article/view/13628/pdf_1
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual De Maringá
publisher.none.fl_str_mv Universidade Estadual De Maringá
dc.source.none.fl_str_mv Acta Scientiarum. Technology; Vol 35 No 3 (2013); 451-456
Acta Scientiarum. Technology; v. 35 n. 3 (2013); 451-456
1806-2563
1807-8664
reponame:Acta scientiarum. Technology (Online)
instname:Universidade Estadual de Maringá (UEM)
instacron:UEM
instname_str Universidade Estadual de Maringá (UEM)
instacron_str UEM
institution UEM
reponame_str Acta scientiarum. Technology (Online)
collection Acta scientiarum. Technology (Online)
repository.name.fl_str_mv Acta scientiarum. Technology (Online) - Universidade Estadual de Maringá (UEM)
repository.mail.fl_str_mv ||actatech@uem.br
_version_ 1799315334367281152