Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea

Detalhes bibliográficos
Autor(a) principal: Costa, Ana Paula Paes da
Data de Publicação: 2021
Outros Autores: paulapaesrj@hotmail.com
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UERJ
Texto Completo: http://www.bdtd.uerj.br/handle/1/19674
Resumo: Staphylococcus aureus bacteremia causes significant morbidity and mortality, mainly by methicillin-resistant S. aureus (MRSA). Currently, vancomycin is the main choice for treatment of MRSA infections. Broth microdilution (BMD) remains the gold standard test for measuring vancomycin minimum inhibitory concentration (MIC). However, most clinical laboratories uses practical methods in the routines, but these methods may not determine vancomycin MIC values accurately. The aim of this study was to evaluate the accuracy of VITEK®2, Phoenix®, Etest® methods to determinate MIC values against BMD. A total of 78 strains (27 methicillin-sensitive S. aureus and 51 MRSA) were isolated from bloodstream infections on patients admitted to an Universitary Hospital in Rio de Janeiro city, Brazil. The vancomycin MIC was determined following Clinical and Laboratory Standards Institute (CLSI) and the manufacturers' recommendations. Also was performed SCCmec typing, in order to identify a possible correlation between the types found with vancomycin MIC values verified in this analysis. Most of all isolates showed values of MIC = 1 μg/mL by BMD and Phoenix®, while Etest® and VITEK® 2 determined the majority with MIC = 1.5 and 0.5 μg/mL, respectively. Thus, Etest® and VITEK® 2 tended to overestimate and underestimate, respectively, the MIC values. Three MRSA isolates that were vancomycin susceptible by BMD were considerated vancomycin-intermediate by Etest®. The SCCmec II (39%) and IV (51%) types were the most frequent, and there was no correlation between the type of SCCmec and the MIC values. The results showed that vancomycin MICs vary according to the test method. It is essential that attending physicians consider the differences in MIC results determined by different methods, since the MIC value is generally one of the laboratorial parameters used to select the appropriate therapy.
id UERJ_35c7a0c1ea948540e8614322b02aaa9e
oai_identifier_str oai:www.bdtd.uerj.br:1/19674
network_acronym_str UERJ
network_name_str Biblioteca Digital de Teses e Dissertações da UERJ
repository_id_str 2903
spelling Nogueira Neto, José Firminohttp://lattes.cnpq.br/2851039552809762Souza, Cláudia Resende Vieira de Mendonçahttp://lattes.cnpq.br/9742270645420446Almeida, Mila Muraro dehttp://lattes.cnpq.br/3901268894149255http://lattes.cnpq.br/2381988184600208Costa, Ana Paula Paes dapaulapaesrj@hotmail.com2023-05-30T16:15:32Z2021-05-19COSTA, Ana Paula Paes da. Avaliação comparativa do Phoenix®, VITEK ®2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea 2021. 34 f. Dissertação (Mestrado em Saúde, Medicina Laboratorial e Tecnologia Forense) – Insituto de Biologia Roberto Alcântara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2021.http://www.bdtd.uerj.br/handle/1/19674Staphylococcus aureus bacteremia causes significant morbidity and mortality, mainly by methicillin-resistant S. aureus (MRSA). Currently, vancomycin is the main choice for treatment of MRSA infections. Broth microdilution (BMD) remains the gold standard test for measuring vancomycin minimum inhibitory concentration (MIC). However, most clinical laboratories uses practical methods in the routines, but these methods may not determine vancomycin MIC values accurately. The aim of this study was to evaluate the accuracy of VITEK®2, Phoenix®, Etest® methods to determinate MIC values against BMD. A total of 78 strains (27 methicillin-sensitive S. aureus and 51 MRSA) were isolated from bloodstream infections on patients admitted to an Universitary Hospital in Rio de Janeiro city, Brazil. The vancomycin MIC was determined following Clinical and Laboratory Standards Institute (CLSI) and the manufacturers' recommendations. Also was performed SCCmec typing, in order to identify a possible correlation between the types found with vancomycin MIC values verified in this analysis. Most of all isolates showed values of MIC = 1 μg/mL by BMD and Phoenix®, while Etest® and VITEK® 2 determined the majority with MIC = 1.5 and 0.5 μg/mL, respectively. Thus, Etest® and VITEK® 2 tended to overestimate and underestimate, respectively, the MIC values. Three MRSA isolates that were vancomycin susceptible by BMD were considerated vancomycin-intermediate by Etest®. The SCCmec II (39%) and IV (51%) types were the most frequent, and there was no correlation between the type of SCCmec and the MIC values. The results showed that vancomycin MICs vary according to the test method. It is essential that attending physicians consider the differences in MIC results determined by different methods, since the MIC value is generally one of the laboratorial parameters used to select the appropriate therapy.Bacteremia por Staphylococcus aureus causa morbidade e mortalidade significativas, principalmente causadas por S.aureus resistente à meticilina (MRSA). Atualmente, a vancomicina é uma das principais drogas de escolha para o tratamento das infecções por MRSA. A microdiluição em caldo (MDC) continua sendo a metodologia considerada padrão-ouro para determinar a concentração inibitória mínima (CIM) para a vancomicina. A maioria dos laboratórios clínicos empregam métodos mais práticos nas rotinas, porém esses métodos podem não determinar os valores de CIM para a vancomicina com precisão. Este estudo teve como objetivo avaliar a acurácia dos valores de CIM obtidos através dos sistemas automatizados Vitek System® 2 e BD Phoenix 100®, bem como do teste de fita gradiente Etest®, frente aos valores obtidos por MDC. Um total de 78 amostras (n=27 de S. aureus sensível à meticilina e n=51 de MRSA) foram isoladas de infecções da corrente sanguínea de pacientes internados em um Hospital Universitário, na cidade do Rio de Janeiro. A CIM para a vancomicina foi determinada seguindo as recomendações do Clinical and Laboratory Standards Institute (CLSI) e dos fabricantes dos sistemas comerciais analisados. Também realizamos a tipagem SCCmec a fim de estabelecer uma possível correlação dos tipos encontrados com os valores de CIMs verificados na análise. A maioria dos isolados apresentou valores de CIM de 1μg/mL por MDC e através do BD Phoenix100®. Etest® e VITEK System®2 determinaram para a maior parte dos isolados CIM de 1,5 e 0,5 μg/mL para a vancomicina, respectivamente. Assim, Etest® e VITEK System®2 tenderam a superestimar e subestimar, respectivamente, os valores de CIM. Três isolados MRSA, sensíveis à vancomicina pela MDC, eram intermediários à vancomicina pelo Etest®. Os tipos SCCmec II (39%) e IV (51%) foram os mais frequentes, não havendo relação entre o tipo de SCCmec e os valores de CIM. Os resultados mostraram que as CIMs para a vancomicina variam de acordo com o método utilizado. É essencial que os médicos considerem que os valores das CIMs podem ser diferentes, dependendo do método utilizado, uma vez que o valor da CIM é geralmente um dos parâmetros laboratoriais mais empregados pelos médicos para selecionar a terapia mais apropriada.Submitted by Heloísa CB/A (helobdtd@gmail.com) on 2023-05-30T16:15:32Z No. of bitstreams: 1 Dissertação - Ana Paula Paes da Costa - 2021 - Completa.pdf: 546293 bytes, checksum: be78a3fa27c950f2360d39335c44d8e3 (MD5)Made available in DSpace on 2023-05-30T16:15:32Z (GMT). No. of bitstreams: 1 Dissertação - Ana Paula Paes da Costa - 2021 - Completa.pdf: 546293 bytes, checksum: be78a3fa27c950f2360d39335c44d8e3 (MD5) Previous issue date: 2021-05-19application/pdfporUniversidade do Estado do Rio de JaneiroPrograma de Pós-Graduação em Saúde, Medicina Laboratorial e Tecnologia ForenseUERJBrasilCentro Biomédico::Instituto de Biologia Roberto Alcantara GomesStaphylococcus aureusVancomycinBloodstream infectionStaphylococcus aureusVancomicinaInfecção da corrente sanguíneaCIENCIAS BIOLOGICAS::MICROBIOLOGIAAvaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguíneaEvaluation of the Phoenix®, VITEK® 2, Etest® and broth microdilution test for susceptibility determination of Staphylococcus aureus to vancomycin in bloodstream infectionsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UERJinstname:Universidade do Estado do Rio de Janeiro (UERJ)instacron:UERJORIGINALDissertação - Ana Paula Paes da Costa - 2021 - Completa.pdfDissertação - Ana Paula Paes da Costa - 2021 - Completa.pdfapplication/pdf546293http://www.bdtd.uerj.br/bitstream/1/19674/2/Disserta%C3%A7%C3%A3o+-+Ana+Paula+Paes+da+Costa+-+2021+-+Completa.pdfbe78a3fa27c950f2360d39335c44d8e3MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82123http://www.bdtd.uerj.br/bitstream/1/19674/1/license.txte5502652da718045d7fcd832b79fca29MD511/196742024-02-26 20:38:09.501oai:www.bdtd.uerj.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://www.bdtd.uerj.br/PUBhttps://www.bdtd.uerj.br:8443/oai/requestbdtd.suporte@uerj.bropendoar:29032024-02-26T23:38:09Biblioteca Digital de Teses e Dissertações da UERJ - Universidade do Estado do Rio de Janeiro (UERJ)false
dc.title.por.fl_str_mv Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
dc.title.alternative.eng.fl_str_mv Evaluation of the Phoenix®, VITEK® 2, Etest® and broth microdilution test for susceptibility determination of Staphylococcus aureus to vancomycin in bloodstream infections
title Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
spellingShingle Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
Costa, Ana Paula Paes da
Staphylococcus aureus
Vancomycin
Bloodstream infection
Staphylococcus aureus
Vancomicina
Infecção da corrente sanguínea
CIENCIAS BIOLOGICAS::MICROBIOLOGIA
title_short Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
title_full Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
title_fullStr Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
title_full_unstemmed Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
title_sort Avaliação comparativa do Phoenix®, VITEK® 2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea
author Costa, Ana Paula Paes da
author_facet Costa, Ana Paula Paes da
paulapaesrj@hotmail.com
author_role author
author2 paulapaesrj@hotmail.com
author2_role author
dc.contributor.advisor1.fl_str_mv Nogueira Neto, José Firmino
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/2851039552809762
dc.contributor.referee1.fl_str_mv Souza, Cláudia Resende Vieira de Mendonça
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/9742270645420446
dc.contributor.referee2.fl_str_mv Almeida, Mila Muraro de
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/3901268894149255
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/2381988184600208
dc.contributor.author.fl_str_mv Costa, Ana Paula Paes da
paulapaesrj@hotmail.com
contributor_str_mv Nogueira Neto, José Firmino
Souza, Cláudia Resende Vieira de Mendonça
Almeida, Mila Muraro de
dc.subject.eng.fl_str_mv Staphylococcus aureus
Vancomycin
Bloodstream infection
topic Staphylococcus aureus
Vancomycin
Bloodstream infection
Staphylococcus aureus
Vancomicina
Infecção da corrente sanguínea
CIENCIAS BIOLOGICAS::MICROBIOLOGIA
dc.subject.por.fl_str_mv Staphylococcus aureus
Vancomicina
Infecção da corrente sanguínea
dc.subject.cnpq.fl_str_mv CIENCIAS BIOLOGICAS::MICROBIOLOGIA
description Staphylococcus aureus bacteremia causes significant morbidity and mortality, mainly by methicillin-resistant S. aureus (MRSA). Currently, vancomycin is the main choice for treatment of MRSA infections. Broth microdilution (BMD) remains the gold standard test for measuring vancomycin minimum inhibitory concentration (MIC). However, most clinical laboratories uses practical methods in the routines, but these methods may not determine vancomycin MIC values accurately. The aim of this study was to evaluate the accuracy of VITEK®2, Phoenix®, Etest® methods to determinate MIC values against BMD. A total of 78 strains (27 methicillin-sensitive S. aureus and 51 MRSA) were isolated from bloodstream infections on patients admitted to an Universitary Hospital in Rio de Janeiro city, Brazil. The vancomycin MIC was determined following Clinical and Laboratory Standards Institute (CLSI) and the manufacturers' recommendations. Also was performed SCCmec typing, in order to identify a possible correlation between the types found with vancomycin MIC values verified in this analysis. Most of all isolates showed values of MIC = 1 μg/mL by BMD and Phoenix®, while Etest® and VITEK® 2 determined the majority with MIC = 1.5 and 0.5 μg/mL, respectively. Thus, Etest® and VITEK® 2 tended to overestimate and underestimate, respectively, the MIC values. Three MRSA isolates that were vancomycin susceptible by BMD were considerated vancomycin-intermediate by Etest®. The SCCmec II (39%) and IV (51%) types were the most frequent, and there was no correlation between the type of SCCmec and the MIC values. The results showed that vancomycin MICs vary according to the test method. It is essential that attending physicians consider the differences in MIC results determined by different methods, since the MIC value is generally one of the laboratorial parameters used to select the appropriate therapy.
publishDate 2021
dc.date.issued.fl_str_mv 2021-05-19
dc.date.accessioned.fl_str_mv 2023-05-30T16:15:32Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv COSTA, Ana Paula Paes da. Avaliação comparativa do Phoenix®, VITEK ®2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea 2021. 34 f. Dissertação (Mestrado em Saúde, Medicina Laboratorial e Tecnologia Forense) – Insituto de Biologia Roberto Alcântara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2021.
dc.identifier.uri.fl_str_mv http://www.bdtd.uerj.br/handle/1/19674
identifier_str_mv COSTA, Ana Paula Paes da. Avaliação comparativa do Phoenix®, VITEK ®2, Etest® e Teste de Microdiluição em Caldo, para determinação do perfil de sensibilidade à vancomicina em Staphylococcus aureus isolado de infecção da corrente sanguínea 2021. 34 f. Dissertação (Mestrado em Saúde, Medicina Laboratorial e Tecnologia Forense) – Insituto de Biologia Roberto Alcântara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2021.
url http://www.bdtd.uerj.br/handle/1/19674
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade do Estado do Rio de Janeiro
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Saúde, Medicina Laboratorial e Tecnologia Forense
dc.publisher.initials.fl_str_mv UERJ
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Centro Biomédico::Instituto de Biologia Roberto Alcantara Gomes
publisher.none.fl_str_mv Universidade do Estado do Rio de Janeiro
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UERJ
instname:Universidade do Estado do Rio de Janeiro (UERJ)
instacron:UERJ
instname_str Universidade do Estado do Rio de Janeiro (UERJ)
instacron_str UERJ
institution UERJ
reponame_str Biblioteca Digital de Teses e Dissertações da UERJ
collection Biblioteca Digital de Teses e Dissertações da UERJ
bitstream.url.fl_str_mv http://www.bdtd.uerj.br/bitstream/1/19674/2/Disserta%C3%A7%C3%A3o+-+Ana+Paula+Paes+da+Costa+-+2021+-+Completa.pdf
http://www.bdtd.uerj.br/bitstream/1/19674/1/license.txt
bitstream.checksum.fl_str_mv be78a3fa27c950f2360d39335c44d8e3
e5502652da718045d7fcd832b79fca29
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UERJ - Universidade do Estado do Rio de Janeiro (UERJ)
repository.mail.fl_str_mv bdtd.suporte@uerj.br
_version_ 1792352380203827200