A review on respiratory muscle training devices

Detalhes bibliográficos
Autor(a) principal: Kênia Kiefer Parreiras de Menezes
Data de Publicação: 2018
Outros Autores: Lucas Rodrigues do Nascimento, Patrick Roberto Avelino, Janaíne Cunha Polese, Luci Fuscaldi Teixeira-Salmela
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFMG
DOI: 10.4172/2161-105X.1000451
Texto Completo: https://doi.org/10.4172/2161-105X.1000451
http://hdl.handle.net/1843/47466
https://orcid.org/0000-0002-9906-9555
https://orcid.org/0000-0002-6792-0819
https://orcid.org/0000-0002-7248-4767
http://orcid.org/0000-0003-3366-1545
https://orcid.org/0000-0001-8358-8636
Resumo: Background and aim: There are currently many devices on the market, which have been used for training of the respiratory muscles. The knowledge of these devices may help professionals to carefully select the best one to be used. However, due to the numerous available devices available, this selection represents a challenge. Although previous studies have attempted to describe all respiratory muscle training devices, important ones with proven efficacy were not included. Therefore, the purpose of this review was to describe the mechanisms and characteristics of all available respiratory muscle training devices, and discuss their merits and limitations. Methods: Searches were conducted in databases, books, website selling products related to rehabilitation, and reference lists of the retrieved papers. Results: The present review included 14 devices currently available on the market and reported by published studies. However, three could not be described in details, due to lack of information. Amongst the 11 evaluated devices, all of them showed positive aspects and limitations that should be considered. Conclusion: Although some devices appear to be more advantageous than others, it is not possible to choose the best one, based only upon their technical information and clinical utility. To select the most appropriate one, it is also necessary to consider the specific health condition, the nature of the impairments, the purpose of the training, and whether it is for use within research or clinical contexts.
id UFMG_3a196e7fbd98117ee712106ed7505a3f
oai_identifier_str oai:repositorio.ufmg.br:1843/47466
network_acronym_str UFMG
network_name_str Repositório Institucional da UFMG
spelling A review on respiratory muscle training devicesRespiratory musclesResistance trainingBreathing exercisesRehabilitationMúsculos respiratóriosTreinamentoExercícios respiratóriosReabilitaçãoBackground and aim: There are currently many devices on the market, which have been used for training of the respiratory muscles. The knowledge of these devices may help professionals to carefully select the best one to be used. However, due to the numerous available devices available, this selection represents a challenge. Although previous studies have attempted to describe all respiratory muscle training devices, important ones with proven efficacy were not included. Therefore, the purpose of this review was to describe the mechanisms and characteristics of all available respiratory muscle training devices, and discuss their merits and limitations. Methods: Searches were conducted in databases, books, website selling products related to rehabilitation, and reference lists of the retrieved papers. Results: The present review included 14 devices currently available on the market and reported by published studies. However, three could not be described in details, due to lack of information. Amongst the 11 evaluated devices, all of them showed positive aspects and limitations that should be considered. Conclusion: Although some devices appear to be more advantageous than others, it is not possible to choose the best one, based only upon their technical information and clinical utility. To select the most appropriate one, it is also necessary to consider the specific health condition, the nature of the impairments, the purpose of the training, and whether it is for use within research or clinical contexts.Universidade Federal de Minas GeraisBrasilEEF - DEPARTAMENTO DE FISIOTERAPIAUFMG2022-11-25T18:40:46Z2022-11-25T18:40:46Z2018info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlepdfapplication/pdfhttps://doi.org/10.4172/2161-105X.10004512161-105Xhttp://hdl.handle.net/1843/47466https://orcid.org/0000-0002-9906-9555https://orcid.org/0000-0002-6792-0819https://orcid.org/0000-0002-7248-4767http://orcid.org/0000-0003-3366-1545https://orcid.org/0000-0001-8358-8636engJournal of Pulmonary and Respiratory MedicineKênia Kiefer Parreiras de MenezesLucas Rodrigues do NascimentoPatrick Roberto AvelinoJanaíne Cunha PoleseLuci Fuscaldi Teixeira-Salmelainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG2022-11-25T18:40:46Zoai:repositorio.ufmg.br:1843/47466Repositório InstitucionalPUBhttps://repositorio.ufmg.br/oairepositorio@ufmg.bropendoar:2022-11-25T18:40:46Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv A review on respiratory muscle training devices
title A review on respiratory muscle training devices
spellingShingle A review on respiratory muscle training devices
A review on respiratory muscle training devices
Kênia Kiefer Parreiras de Menezes
Respiratory muscles
Resistance training
Breathing exercises
Rehabilitation
Músculos respiratórios
Treinamento
Exercícios respiratórios
Reabilitação
Kênia Kiefer Parreiras de Menezes
Respiratory muscles
Resistance training
Breathing exercises
Rehabilitation
Músculos respiratórios
Treinamento
Exercícios respiratórios
Reabilitação
title_short A review on respiratory muscle training devices
title_full A review on respiratory muscle training devices
title_fullStr A review on respiratory muscle training devices
A review on respiratory muscle training devices
title_full_unstemmed A review on respiratory muscle training devices
A review on respiratory muscle training devices
title_sort A review on respiratory muscle training devices
author Kênia Kiefer Parreiras de Menezes
author_facet Kênia Kiefer Parreiras de Menezes
Kênia Kiefer Parreiras de Menezes
Lucas Rodrigues do Nascimento
Patrick Roberto Avelino
Janaíne Cunha Polese
Luci Fuscaldi Teixeira-Salmela
Lucas Rodrigues do Nascimento
Patrick Roberto Avelino
Janaíne Cunha Polese
Luci Fuscaldi Teixeira-Salmela
author_role author
author2 Lucas Rodrigues do Nascimento
Patrick Roberto Avelino
Janaíne Cunha Polese
Luci Fuscaldi Teixeira-Salmela
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Kênia Kiefer Parreiras de Menezes
Lucas Rodrigues do Nascimento
Patrick Roberto Avelino
Janaíne Cunha Polese
Luci Fuscaldi Teixeira-Salmela
dc.subject.por.fl_str_mv Respiratory muscles
Resistance training
Breathing exercises
Rehabilitation
Músculos respiratórios
Treinamento
Exercícios respiratórios
Reabilitação
topic Respiratory muscles
Resistance training
Breathing exercises
Rehabilitation
Músculos respiratórios
Treinamento
Exercícios respiratórios
Reabilitação
description Background and aim: There are currently many devices on the market, which have been used for training of the respiratory muscles. The knowledge of these devices may help professionals to carefully select the best one to be used. However, due to the numerous available devices available, this selection represents a challenge. Although previous studies have attempted to describe all respiratory muscle training devices, important ones with proven efficacy were not included. Therefore, the purpose of this review was to describe the mechanisms and characteristics of all available respiratory muscle training devices, and discuss their merits and limitations. Methods: Searches were conducted in databases, books, website selling products related to rehabilitation, and reference lists of the retrieved papers. Results: The present review included 14 devices currently available on the market and reported by published studies. However, three could not be described in details, due to lack of information. Amongst the 11 evaluated devices, all of them showed positive aspects and limitations that should be considered. Conclusion: Although some devices appear to be more advantageous than others, it is not possible to choose the best one, based only upon their technical information and clinical utility. To select the most appropriate one, it is also necessary to consider the specific health condition, the nature of the impairments, the purpose of the training, and whether it is for use within research or clinical contexts.
publishDate 2018
dc.date.none.fl_str_mv 2018
2022-11-25T18:40:46Z
2022-11-25T18:40:46Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.4172/2161-105X.1000451
2161-105X
http://hdl.handle.net/1843/47466
https://orcid.org/0000-0002-9906-9555
https://orcid.org/0000-0002-6792-0819
https://orcid.org/0000-0002-7248-4767
http://orcid.org/0000-0003-3366-1545
https://orcid.org/0000-0001-8358-8636
url https://doi.org/10.4172/2161-105X.1000451
http://hdl.handle.net/1843/47466
https://orcid.org/0000-0002-9906-9555
https://orcid.org/0000-0002-6792-0819
https://orcid.org/0000-0002-7248-4767
http://orcid.org/0000-0003-3366-1545
https://orcid.org/0000-0001-8358-8636
identifier_str_mv 2161-105X
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Pulmonary and Respiratory Medicine
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais
Brasil
EEF - DEPARTAMENTO DE FISIOTERAPIA
UFMG
publisher.none.fl_str_mv Universidade Federal de Minas Gerais
Brasil
EEF - DEPARTAMENTO DE FISIOTERAPIA
UFMG
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFMG
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Repositório Institucional da UFMG
collection Repositório Institucional da UFMG
repository.name.fl_str_mv Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv repositorio@ufmg.br
_version_ 1822183088402202624
dc.identifier.doi.none.fl_str_mv 10.4172/2161-105X.1000451