Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais

Detalhes bibliográficos
Autor(a) principal: Rodrigues, Yriu Lourenço
Data de Publicação: 2015
Tipo de documento: Trabalho de conclusão de curso
Idioma: por
Título da fonte: Repositório Institucional da UFRN
Texto Completo: https://repositorio.ufrn.br/handle/123456789/39246
Resumo: Objective: This study aims to evaluate the physical properties of plates and screws three trademarks, used in rigid internal fixation of facial fractures and osteotomies. Methods: 30 plates and 30 screws, divided among the trademarks BioMKTM, Engimplan® and W. OsteoMedTM , belonging 2.0 mm and 1.5 mm systems will be used. The groups have undergone laboratory testing and the flexural strength tests and metrology analysis of standardization and accuracy. The results obtained in the study were subjected to the Kruskal-Wallis Test, Mann-Whitney and Tukey the 1% significance level, to evaluate the relation between the groups. Results: It can be observed that in the metrology analysis of standardization and accuracy of the plates there was no statistically significant difference between commercial brands analyzed, but already the screws was no statistically significant difference between OsteoMedTM brand and the other two brands, both 2.0 mm system as in System 1.5 mm. With respect to flexural strength can observe a statistically significant difference between brands of plates, on all systems, since the screws there was no statistically significant difference between the 2.0 mm System brands, but at 1.5 mm system. All trademarks that had better results in the macroscopic analysis of standardization and accuracy necessarily had better results in bending tests in their respective systems. Conclusion: Thus we can conclude that not there is a system with better results in all parameters, but there is a clear relationship between the standardization and accuracy of systems with its resistance to flexion, which will certainly reflect in a more efficient surgical procedure and prognosis more favorable.
id UFRN_664a6b973d5ad40103b33c9ba69892fe
oai_identifier_str oai:https://repositorio.ufrn.br:123456789/39246
network_acronym_str UFRN
network_name_str Repositório Institucional da UFRN
repository_id_str
spelling Rodrigues, Yriu LourençoSilva, José Sandro Pereira daGomes, Petrus PereiraSilva, Wanderson Santana daGermano, Adriano Rocha2015-11-25T14:05:12Z2021-09-27T14:09:26Z2015-11-25T14:05:12Z2021-09-27T14:09:26Z2015-06-102011034360RODRIGUES, Yriu Lourenço. Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais. 2015. 12 f. TCC (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2015.https://repositorio.ufrn.br/handle/123456789/39246Objective: This study aims to evaluate the physical properties of plates and screws three trademarks, used in rigid internal fixation of facial fractures and osteotomies. Methods: 30 plates and 30 screws, divided among the trademarks BioMKTM, Engimplan® and W. OsteoMedTM , belonging 2.0 mm and 1.5 mm systems will be used. The groups have undergone laboratory testing and the flexural strength tests and metrology analysis of standardization and accuracy. The results obtained in the study were subjected to the Kruskal-Wallis Test, Mann-Whitney and Tukey the 1% significance level, to evaluate the relation between the groups. Results: It can be observed that in the metrology analysis of standardization and accuracy of the plates there was no statistically significant difference between commercial brands analyzed, but already the screws was no statistically significant difference between OsteoMedTM brand and the other two brands, both 2.0 mm system as in System 1.5 mm. With respect to flexural strength can observe a statistically significant difference between brands of plates, on all systems, since the screws there was no statistically significant difference between the 2.0 mm System brands, but at 1.5 mm system. All trademarks that had better results in the macroscopic analysis of standardization and accuracy necessarily had better results in bending tests in their respective systems. Conclusion: Thus we can conclude that not there is a system with better results in all parameters, but there is a clear relationship between the standardization and accuracy of systems with its resistance to flexion, which will certainly reflect in a more efficient surgical procedure and prognosis more favorable.Objetivo: Esse estudo tem o objetivo de avaliar as propriedades físicas de placas e parafusos de três marcas comerciais, utilizados na fixação interna rígida de fraturas e osteotomias faciais. Método: Foram utilizadas 30 placas e 30 parafusos, divididos entre as marcas comerciais BioMKTM , Engimplan® e OsteoMedTM , pertencentes aos sistemas de 2,0 mm e 1,5 mm. Os grupos passaram por análise metrológica de padronização e precisão e ensaios laboratoriais de testes de resistência ao dobramento. Os resultados obtidos nos estudos foram submetidos a Testes de Kruskal-Wallis, MannWhitney e Tukey ao nível de significância de 1%, para avaliar qual a relação entre os grupos. Resultados: Pode-se observar que na análise metrológica de padronização e precisão das placas não houve diferença estatisticamente significante entre as marcas comerciais analisadas, mas já nos parafusos houve diferença estatisticamente significante entre a marca OsteoMedTM e as outras duas marcas, tanto no sistema 2.0 mm quanto no sistema 1.5 mm. Com relação à resistência ao dobramento pode-se observar que houve diferença estatisticamente significante entre as marcas das placas, em todos os sistemas, já nos parafusos não houve diferença estatisticamente significante entre as marcas do sistema 2.0 mm, mas sim no sistema 1.5 mm. Todas as marcas comerciais que tiveram melhores resultados na análise metrológica de padronização e precisão tiveram necessariamente melhores resultados nos testes de dobramento nos seus respectivos sistemas. Conclusão: Dessa forma podemos concluir que não existe um sistema com melhores resultados em todos os parâmetros, mas que há uma clara relação entre a padronização e precisão dos sistemas com sua resistência ao dobramento, o que certamente refletirá em um procedimento cirúrgico mais eficaz e com prognóstico mais favorável.Universidade Federal do Rio Grande do NorteUFRNBrasilOdontologiaPlacas ósseasParafusos ósseosFixação interna de fraturasResistencia de MateriaisAnálise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciaisMetrology and mechanical analysis components for fixing Systems used in osteosynthesis of maxillofacial surgeriesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNTEXT[2015] ANÁLISE METROLÓGICA E MECÂNICA DE COMPONENTES DE SISTEMAS DE FIXAÇÃO UTILIZADOS NAS OSTEOSSÍNTESES.pdf.txtExtracted texttext/plain33149https://repositorio.ufrn.br/bitstream/123456789/39246/1/%5b2015%5d%20AN%c3%81LISE%20METROL%c3%93GICA%20E%20MEC%c3%82NICA%20DE%20COMPONENTES%20DE%20SISTEMAS%20DE%20FIXA%c3%87%c3%83O%20UTILIZADOS%20NAS%20OSTEOSS%c3%8dNTESES.pdf.txtb484645476a24b2ece70606044aa7edfMD51ORIGINALAnaliseMecanicaSistemas_Rodrigues_2015.pdftrabalho de conclusão de curso - odontologia 2015.1application/pdf787466https://repositorio.ufrn.br/bitstream/123456789/39246/2/AnaliseMecanicaSistemas_Rodrigues_2015.pdf9a32201e683a7a85caf724335842fe90MD52LICENSElicense.txttext/plain756https://repositorio.ufrn.br/bitstream/123456789/39246/3/license.txta80a9cda2756d355b388cc443c3d8a43MD53123456789/392462023-05-03 09:24:43.812oai:https://repositorio.ufrn.br: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ório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2023-05-03T12:24:43Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false
dc.title.pr_BR.fl_str_mv Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
dc.title.alternative.pr_BR.fl_str_mv Metrology and mechanical analysis components for fixing Systems used in osteosynthesis of maxillofacial surgeries
title Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
spellingShingle Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
Rodrigues, Yriu Lourenço
Placas ósseas
Parafusos ósseos
Fixação interna de fraturas
Resistencia de Materiais
title_short Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
title_full Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
title_fullStr Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
title_full_unstemmed Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
title_sort Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais
author Rodrigues, Yriu Lourenço
author_facet Rodrigues, Yriu Lourenço
author_role author
dc.contributor.referees1.none.fl_str_mv Silva, José Sandro Pereira da
dc.contributor.referees2.none.fl_str_mv Gomes, Petrus Pereira
dc.contributor.referees3.none.fl_str_mv Silva, Wanderson Santana da
dc.contributor.author.fl_str_mv Rodrigues, Yriu Lourenço
dc.contributor.advisor1.fl_str_mv Germano, Adriano Rocha
contributor_str_mv Germano, Adriano Rocha
dc.subject.pr_BR.fl_str_mv Placas ósseas
Parafusos ósseos
Fixação interna de fraturas
Resistencia de Materiais
topic Placas ósseas
Parafusos ósseos
Fixação interna de fraturas
Resistencia de Materiais
description Objective: This study aims to evaluate the physical properties of plates and screws three trademarks, used in rigid internal fixation of facial fractures and osteotomies. Methods: 30 plates and 30 screws, divided among the trademarks BioMKTM, Engimplan® and W. OsteoMedTM , belonging 2.0 mm and 1.5 mm systems will be used. The groups have undergone laboratory testing and the flexural strength tests and metrology analysis of standardization and accuracy. The results obtained in the study were subjected to the Kruskal-Wallis Test, Mann-Whitney and Tukey the 1% significance level, to evaluate the relation between the groups. Results: It can be observed that in the metrology analysis of standardization and accuracy of the plates there was no statistically significant difference between commercial brands analyzed, but already the screws was no statistically significant difference between OsteoMedTM brand and the other two brands, both 2.0 mm system as in System 1.5 mm. With respect to flexural strength can observe a statistically significant difference between brands of plates, on all systems, since the screws there was no statistically significant difference between the 2.0 mm System brands, but at 1.5 mm system. All trademarks that had better results in the macroscopic analysis of standardization and accuracy necessarily had better results in bending tests in their respective systems. Conclusion: Thus we can conclude that not there is a system with better results in all parameters, but there is a clear relationship between the standardization and accuracy of systems with its resistance to flexion, which will certainly reflect in a more efficient surgical procedure and prognosis more favorable.
publishDate 2015
dc.date.accessioned.fl_str_mv 2015-11-25T14:05:12Z
2021-09-27T14:09:26Z
dc.date.available.fl_str_mv 2015-11-25T14:05:12Z
2021-09-27T14:09:26Z
dc.date.issued.fl_str_mv 2015-06-10
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.pr_BR.fl_str_mv 2011034360
dc.identifier.citation.fl_str_mv RODRIGUES, Yriu Lourenço. Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais. 2015. 12 f. TCC (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2015.
dc.identifier.uri.fl_str_mv https://repositorio.ufrn.br/handle/123456789/39246
identifier_str_mv 2011034360
RODRIGUES, Yriu Lourenço. Análise metrológica e mecânica de componentes de sistemas de fixação utilizados nas osteossínteses de cirurgias buco-maxilo-faciais. 2015. 12 f. TCC (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2015.
url https://repositorio.ufrn.br/handle/123456789/39246
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.publisher.initials.fl_str_mv UFRN
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Odontologia
publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRN
instname:Universidade Federal do Rio Grande do Norte (UFRN)
instacron:UFRN
instname_str Universidade Federal do Rio Grande do Norte (UFRN)
instacron_str UFRN
institution UFRN
reponame_str Repositório Institucional da UFRN
collection Repositório Institucional da UFRN
bitstream.url.fl_str_mv https://repositorio.ufrn.br/bitstream/123456789/39246/1/%5b2015%5d%20AN%c3%81LISE%20METROL%c3%93GICA%20E%20MEC%c3%82NICA%20DE%20COMPONENTES%20DE%20SISTEMAS%20DE%20FIXA%c3%87%c3%83O%20UTILIZADOS%20NAS%20OSTEOSS%c3%8dNTESES.pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/39246/2/AnaliseMecanicaSistemas_Rodrigues_2015.pdf
https://repositorio.ufrn.br/bitstream/123456789/39246/3/license.txt
bitstream.checksum.fl_str_mv b484645476a24b2ece70606044aa7edf
9a32201e683a7a85caf724335842fe90
a80a9cda2756d355b388cc443c3d8a43
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)
repository.mail.fl_str_mv
_version_ 1814832922254901248