Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFS |
Texto Completo: | https://ri.ufs.br/handle/riufs/608 |
Resumo: | The determination of chemical purity, melting range, and variation of enthalpy in the process of characterizing medicines is one of the principal requirements evaluated in quality control of the pharmaceutical industry. In this study, the method of purity determination using DSC was outlined, as well as the application of this technique for the evaluation of commercial samples of zidovudine (AZT) (raw material) supplied by different laboratories. To this end, samples from six different laboratories (A, B, C, D, E, and F) and the standard reference (R) from the United States Pharmacopeia (USP) were analyzed. The DSC curves were obtained in the temperature range of 25 to 200 ºC under the dynamic atmosphere of N2 (50 mL min-1), heating rate of β=2 ºC min-1, using an Al capsule containing approximately 2 mg of sample material. The results demonstrated that the standard reference presented a proportion of 99.83% whereas the AZT samples presented a variation ranging from 97.59 to 99.54%. In addition, the standard reference was found to present a temperature of onset of melting point of 122.80 °C. Regarding the samples of active agents provided by the different laboratories, a variation ranging from 118.70 to 122.87 °C was measured. In terms of ΔHm, the samples presented an average value of 31.12 kJ mol-1._________________________________________________________________________________________ RESUMO: A determinação da pureza química, a faixa de fusão e a variação de entalpia envolvida no processo de caracterização de fármacos é um dos principais requisitos avaliados no controle de qualidade em indústrias farmacêuticas. Neste trabalho é feita uma breve abordagem sobre o método de determinação de pureza utilizando DSC, assim como a aplicação desta técnica para avaliação de amostras comerciais de zidovudina (AZT) (matéria-prima) fornecida por diferentes laboratórios. Para tal, foram analisadas amostras de seis diferentes laboratórios (A,B,C,D,E e F) e a substância química de referência (R) da United States Pharmacopeia (USP). As curvas DSC foram obtidas na faixa de temperatura entre 25 a 200 ºC, sob atmosfera dinâmica de N2 (50 mL min-1), β=2 ºC min-1, utilizando cápsula de Al contendo aproximadamente 2 mg de amostra. De acordo com os resultados, pode-se observar que a substância química de referência apresentou teor igual a 99,83% e que as amostras de AZT apresentaram uma faixa de variação entre 97,59 e 99,54%. Pode-se verificar, ainda, que a substância química de referência apresentou uma temperatura onset de fusão igual a 122,80 °C. Para as amostras dos princípios ativos fornecidos pelos diferentes laboratórios, pode-se verificar uma faixa de variação entre 118,70 e 122,87 °C. No que se refere ao ΔHm, as amostras apresentaram valor médio de 31,12 kJ.mol-1. |
id |
UFS-2_4e63e55f33e25d3136b3c2b22cb8f55b |
---|---|
oai_identifier_str |
oai:ufs.br:riufs/608 |
network_acronym_str |
UFS-2 |
network_name_str |
Repositório Institucional da UFS |
repository_id_str |
|
spelling |
Araújo, Adriano Antunes de SouzaBezerra, Marília dos SantosStorpirtis, SílviaMatos, Jivaldo do Rosário2013-06-11T19:09:01Z2013-06-11T19:09:01Z2010-03ARAUJO, A. A. S. et al. Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC. Brazilian Journal of Pharmaceutical Sciences, São Paulo, v. 46, n. 1, mar. 2010. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000100005&lng=en&nrm=iso>. Acesso em: 11 jun. 2013.1984-8250https://ri.ufs.br/handle/riufs/608Creative Commons Attribution LicenseThe determination of chemical purity, melting range, and variation of enthalpy in the process of characterizing medicines is one of the principal requirements evaluated in quality control of the pharmaceutical industry. In this study, the method of purity determination using DSC was outlined, as well as the application of this technique for the evaluation of commercial samples of zidovudine (AZT) (raw material) supplied by different laboratories. To this end, samples from six different laboratories (A, B, C, D, E, and F) and the standard reference (R) from the United States Pharmacopeia (USP) were analyzed. The DSC curves were obtained in the temperature range of 25 to 200 ºC under the dynamic atmosphere of N2 (50 mL min-1), heating rate of β=2 ºC min-1, using an Al capsule containing approximately 2 mg of sample material. The results demonstrated that the standard reference presented a proportion of 99.83% whereas the AZT samples presented a variation ranging from 97.59 to 99.54%. In addition, the standard reference was found to present a temperature of onset of melting point of 122.80 °C. Regarding the samples of active agents provided by the different laboratories, a variation ranging from 118.70 to 122.87 °C was measured. In terms of ΔHm, the samples presented an average value of 31.12 kJ mol-1._________________________________________________________________________________________ RESUMO: A determinação da pureza química, a faixa de fusão e a variação de entalpia envolvida no processo de caracterização de fármacos é um dos principais requisitos avaliados no controle de qualidade em indústrias farmacêuticas. Neste trabalho é feita uma breve abordagem sobre o método de determinação de pureza utilizando DSC, assim como a aplicação desta técnica para avaliação de amostras comerciais de zidovudina (AZT) (matéria-prima) fornecida por diferentes laboratórios. Para tal, foram analisadas amostras de seis diferentes laboratórios (A,B,C,D,E e F) e a substância química de referência (R) da United States Pharmacopeia (USP). As curvas DSC foram obtidas na faixa de temperatura entre 25 a 200 ºC, sob atmosfera dinâmica de N2 (50 mL min-1), β=2 ºC min-1, utilizando cápsula de Al contendo aproximadamente 2 mg de amostra. De acordo com os resultados, pode-se observar que a substância química de referência apresentou teor igual a 99,83% e que as amostras de AZT apresentaram uma faixa de variação entre 97,59 e 99,54%. Pode-se verificar, ainda, que a substância química de referência apresentou uma temperatura onset de fusão igual a 122,80 °C. Para as amostras dos princípios ativos fornecidos pelos diferentes laboratórios, pode-se verificar uma faixa de variação entre 118,70 e 122,87 °C. No que se refere ao ΔHm, as amostras apresentaram valor médio de 31,12 kJ.mol-1.ZidovudinaDeterminação da purezaCalorimetriaAnálise térmicaMedicamentosControle de qualidadeAnálise qualitativaDetermination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSCinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleengreponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSinfo:eu-repo/semantics/openAccessTHUMBNAILDeterminationZidovudineDSC.pdf.jpgDeterminationZidovudineDSC.pdf.jpgGenerated Thumbnailimage/jpeg1609https://ri.ufs.br/jspui/bitstream/riufs/608/4/DeterminationZidovudineDSC.pdf.jpg6b7e782255535aafbb2c1b5c7e3b1a6bMD54ORIGINALDeterminationZidovudineDSC.pdfDeterminationZidovudineDSC.pdfapplication/pdf701151https://ri.ufs.br/jspui/bitstream/riufs/608/1/DeterminationZidovudineDSC.pdfbf97e4b7947fbc6697104b8fbb3de97cMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://ri.ufs.br/jspui/bitstream/riufs/608/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52TEXTDeterminationZidovudineDSC.pdf.txtDeterminationZidovudineDSC.pdf.txtExtracted texttext/plain24161https://ri.ufs.br/jspui/bitstream/riufs/608/3/DeterminationZidovudineDSC.pdf.txt1e9b3add124cd23b6852eb5187bd2958MD53riufs/6082013-06-12 02:00:11.906oai:ufs.br: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Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2013-06-12T05:00:11Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false |
dc.title.pt_BR.fl_str_mv |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC |
title |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC |
spellingShingle |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC Araújo, Adriano Antunes de Souza Zidovudina Determinação da pureza Calorimetria Análise térmica Medicamentos Controle de qualidade Análise qualitativa |
title_short |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC |
title_full |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC |
title_fullStr |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC |
title_full_unstemmed |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC |
title_sort |
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC |
author |
Araújo, Adriano Antunes de Souza |
author_facet |
Araújo, Adriano Antunes de Souza Bezerra, Marília dos Santos Storpirtis, Sílvia Matos, Jivaldo do Rosário |
author_role |
author |
author2 |
Bezerra, Marília dos Santos Storpirtis, Sílvia Matos, Jivaldo do Rosário |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Araújo, Adriano Antunes de Souza Bezerra, Marília dos Santos Storpirtis, Sílvia Matos, Jivaldo do Rosário |
dc.subject.por.fl_str_mv |
Zidovudina Determinação da pureza Calorimetria Análise térmica Medicamentos Controle de qualidade Análise qualitativa |
topic |
Zidovudina Determinação da pureza Calorimetria Análise térmica Medicamentos Controle de qualidade Análise qualitativa |
description |
The determination of chemical purity, melting range, and variation of enthalpy in the process of characterizing medicines is one of the principal requirements evaluated in quality control of the pharmaceutical industry. In this study, the method of purity determination using DSC was outlined, as well as the application of this technique for the evaluation of commercial samples of zidovudine (AZT) (raw material) supplied by different laboratories. To this end, samples from six different laboratories (A, B, C, D, E, and F) and the standard reference (R) from the United States Pharmacopeia (USP) were analyzed. The DSC curves were obtained in the temperature range of 25 to 200 ºC under the dynamic atmosphere of N2 (50 mL min-1), heating rate of β=2 ºC min-1, using an Al capsule containing approximately 2 mg of sample material. The results demonstrated that the standard reference presented a proportion of 99.83% whereas the AZT samples presented a variation ranging from 97.59 to 99.54%. In addition, the standard reference was found to present a temperature of onset of melting point of 122.80 °C. Regarding the samples of active agents provided by the different laboratories, a variation ranging from 118.70 to 122.87 °C was measured. In terms of ΔHm, the samples presented an average value of 31.12 kJ mol-1._________________________________________________________________________________________ RESUMO: A determinação da pureza química, a faixa de fusão e a variação de entalpia envolvida no processo de caracterização de fármacos é um dos principais requisitos avaliados no controle de qualidade em indústrias farmacêuticas. Neste trabalho é feita uma breve abordagem sobre o método de determinação de pureza utilizando DSC, assim como a aplicação desta técnica para avaliação de amostras comerciais de zidovudina (AZT) (matéria-prima) fornecida por diferentes laboratórios. Para tal, foram analisadas amostras de seis diferentes laboratórios (A,B,C,D,E e F) e a substância química de referência (R) da United States Pharmacopeia (USP). As curvas DSC foram obtidas na faixa de temperatura entre 25 a 200 ºC, sob atmosfera dinâmica de N2 (50 mL min-1), β=2 ºC min-1, utilizando cápsula de Al contendo aproximadamente 2 mg de amostra. De acordo com os resultados, pode-se observar que a substância química de referência apresentou teor igual a 99,83% e que as amostras de AZT apresentaram uma faixa de variação entre 97,59 e 99,54%. Pode-se verificar, ainda, que a substância química de referência apresentou uma temperatura onset de fusão igual a 122,80 °C. Para as amostras dos princípios ativos fornecidos pelos diferentes laboratórios, pode-se verificar uma faixa de variação entre 118,70 e 122,87 °C. No que se refere ao ΔHm, as amostras apresentaram valor médio de 31,12 kJ.mol-1. |
publishDate |
2010 |
dc.date.issued.fl_str_mv |
2010-03 |
dc.date.accessioned.fl_str_mv |
2013-06-11T19:09:01Z |
dc.date.available.fl_str_mv |
2013-06-11T19:09:01Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
ARAUJO, A. A. S. et al. Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC. Brazilian Journal of Pharmaceutical Sciences, São Paulo, v. 46, n. 1, mar. 2010. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000100005&lng=en&nrm=iso>. Acesso em: 11 jun. 2013. |
dc.identifier.uri.fl_str_mv |
https://ri.ufs.br/handle/riufs/608 |
dc.identifier.issn.none.fl_str_mv |
1984-8250 |
dc.identifier.license.pt_BR.fl_str_mv |
Creative Commons Attribution License |
identifier_str_mv |
ARAUJO, A. A. S. et al. Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC. Brazilian Journal of Pharmaceutical Sciences, São Paulo, v. 46, n. 1, mar. 2010. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000100005&lng=en&nrm=iso>. Acesso em: 11 jun. 2013. 1984-8250 Creative Commons Attribution License |
url |
https://ri.ufs.br/handle/riufs/608 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFS instname:Universidade Federal de Sergipe (UFS) instacron:UFS |
instname_str |
Universidade Federal de Sergipe (UFS) |
instacron_str |
UFS |
institution |
UFS |
reponame_str |
Repositório Institucional da UFS |
collection |
Repositório Institucional da UFS |
bitstream.url.fl_str_mv |
https://ri.ufs.br/jspui/bitstream/riufs/608/4/DeterminationZidovudineDSC.pdf.jpg https://ri.ufs.br/jspui/bitstream/riufs/608/1/DeterminationZidovudineDSC.pdf https://ri.ufs.br/jspui/bitstream/riufs/608/2/license.txt https://ri.ufs.br/jspui/bitstream/riufs/608/3/DeterminationZidovudineDSC.pdf.txt |
bitstream.checksum.fl_str_mv |
6b7e782255535aafbb2c1b5c7e3b1a6b bf97e4b7947fbc6697104b8fbb3de97c 8a4605be74aa9ea9d79846c1fba20a33 1e9b3add124cd23b6852eb5187bd2958 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS) |
repository.mail.fl_str_mv |
repositorio@academico.ufs.br |
_version_ |
1802110755995123712 |