Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações do UFSM |
Texto Completo: | http://repositorio.ufsm.br/handle/1/5994 |
Resumo: | Erythropoietin is a glycoprotein which stimulates the erythropoiesis, clinically used for the treatment of renal anaemia. The biological and chromatographic methods for the potency evaluation of recombinant human erythropoietin (rhEPO) in pharmaceutical products were validated in the present work. The normocythaemic mice bioassay was carried out in female BALB/c strain, with multiple injections schedule and reticulocytes counted by automated flow cytometry. The dose-response curve was linear (r2=0.9708) in the concentration range of 1 to 64 IU/mL. A reversed-phase liquid chromatography method (RP-LC) was developed and validated using a Jupiter C4 column (250 mm x 4.6 mm), maintained at ambient temperature (25°C). The mobile phase A consisted of 0.1% trifluoroacetic acid (TFA) and mobile phase B consisted of 0.08% TFA:acetonitrile (30:70, v/v), run in linear gradient: 0.1-60 min, 0.1-100% of B at flow rate of 0.5 mL/min with detection at 280 nm. The chromatographic separation was obtained within 60 min and it was linear (r2=0.9997) in the concentration range of 10-150 μg/mL. The procedures were validated evaluating parameters such as, the specificity, linearity, precision, accuracy, robustness, and limit of quantitation, as well as, the limit of detection evaluated in the validation of the chromatographic method. The methods were applied for the potency evaluation of the alfa and beta rhEPO in pharmaceutical products, which were analysed by the chromatographic method and compared to the bioassay showing mean differences between the estimated potencies of 11.2% higher for the RP-LC. The alternative established represents a contribution towards the replacement of the animals improving the quality control and assuring the safety and efficacy of the biological product. |
id |
UFSM_b81037ea141fcd10d0d5d3bca826f1e2 |
---|---|
oai_identifier_str |
oai:repositorio.ufsm.br:1/5994 |
network_acronym_str |
UFSM |
network_name_str |
Biblioteca Digital de Teses e Dissertações do UFSM |
repository_id_str |
|
spelling |
2007-05-252007-05-252007-04-10BARTH, Thiago. Development and validation of chromatographic method for the potency assessment of recombinant human erythropoietin. Correlation with the biological assay. 2007. 88 f. Dissertação (Mestrado em Farmacologia) - Universidade Federal de Santa Maria, Santa Maria, 2007.http://repositorio.ufsm.br/handle/1/5994Erythropoietin is a glycoprotein which stimulates the erythropoiesis, clinically used for the treatment of renal anaemia. The biological and chromatographic methods for the potency evaluation of recombinant human erythropoietin (rhEPO) in pharmaceutical products were validated in the present work. The normocythaemic mice bioassay was carried out in female BALB/c strain, with multiple injections schedule and reticulocytes counted by automated flow cytometry. The dose-response curve was linear (r2=0.9708) in the concentration range of 1 to 64 IU/mL. A reversed-phase liquid chromatography method (RP-LC) was developed and validated using a Jupiter C4 column (250 mm x 4.6 mm), maintained at ambient temperature (25°C). The mobile phase A consisted of 0.1% trifluoroacetic acid (TFA) and mobile phase B consisted of 0.08% TFA:acetonitrile (30:70, v/v), run in linear gradient: 0.1-60 min, 0.1-100% of B at flow rate of 0.5 mL/min with detection at 280 nm. The chromatographic separation was obtained within 60 min and it was linear (r2=0.9997) in the concentration range of 10-150 μg/mL. The procedures were validated evaluating parameters such as, the specificity, linearity, precision, accuracy, robustness, and limit of quantitation, as well as, the limit of detection evaluated in the validation of the chromatographic method. The methods were applied for the potency evaluation of the alfa and beta rhEPO in pharmaceutical products, which were analysed by the chromatographic method and compared to the bioassay showing mean differences between the estimated potencies of 11.2% higher for the RP-LC. The alternative established represents a contribution towards the replacement of the animals improving the quality control and assuring the safety and efficacy of the biological product.Eritropoietina é uma glicoproteína que estimula a eritropoiese e é usada clinicamente para o tratamento de anemias associadas à falência renal crônica. No presente trabalho foram validados métodos biológico e cromatográfico para a avaliação de potência de eritropoietina humana recombinante (rhEPO) em produtos farmacêuticos. O ensaio biológico foi validado em camundongos normocitêmicos, fêmeas, da linhagem BALB/c, com protocolo de injeções múltiplas e contagem automatizada dos reticulócitos por citometria de fluxo. A curva doseresposta foi linear (r2=0,9708) na faixa de concentração de 1 a 64 UI/mL. Paralelamente, desenvolveu-se e validou-se método por cromatografia líquida em fase reversa (CL-FR) empregando coluna Júpiter C4 (250 mm x 4,6 mm), mantida a temperatura ambiente (25°C). A fase móvel A foi composta de ácido trifluoracético 0,1% e a fase móvel B composta de acetonitrila/ácido trifluoracético 0,08% (70:30, v/v), eluída em gradiente linear: 0,1 60 min, 0 100% de B, na vazão de 0,5 mL/min e detecção no ultravioleta a 280 nm. A separação cromatográfica foi obtida no tempo de 60 min, sendo linear (r2=0,9997) na faixa de concentração de 10-150 μg/mL. Ambos procedimentos foram validados com base nos parâmetros de especificidade, linearidade, precisão, exatidão, robustez e limite de quantificação, bem como limite de detecção, avaliado na validação do método cromatográfico. Os métodos foram aplicados na avaliação de potência de rhEPO alfa e beta em produtos farmacêuticos e estudou-se a correlação entre os métodos. Demonstrou-se que as análises dos produtos farmacêuticos forneceram diferenças médias de potência 11,2 % superiores para o CL-FR. Desse modo, estabeleceu-se alternativa no contexto da substituição do uso de animais, contribuindo para aprimorar o controle da qualidade, garantindo a segurança e eficácia terapêutica do produto biológico.Eritropoietina é uma glicoproteína que estimula a eritropoiese e é usada clinicamente para o tratamento de anemias associadas à falência renal crônica. No presente trabalho foram validados métodos biológico e cromatográfico para a avaliação de potência de eritropoietina humana recombinante (rhEPO) em produtos farmacêuticos. O ensaio biológico foi validado em camundongos normocitêmicos, fêmeas, da linhagem BALB/c, com protocolo de injeções múltiplas e contagem automatizada dos reticulócitos por citometria de fluxo. A curva doseresposta foi linear (r2=0,9708) na faixa de concentração de 1 a 64 UI/mL. Paralelamente, desenvolveu-se e validou-se método por cromatografia líquida em fase reversa (CL-FR) empregando coluna Júpiter C4 (250 mm x 4,6 mm), mantida a temperatura ambiente (25°C). A fase móvel A foi composta de ácido trifluoracético 0,1% e a fase móvel B composta de acetonitrila/ácido trifluoracético 0,08% (70:30, v/v), eluída em gradiente linear: 0,1 60 min, 0 100% de B, na vazão de 0,5 mL/min e detecção no ultravioleta a 280 nm. A separação cromatográfica foi obtida no tempo de 60 min, sendo linear (r2=0,9997) na faixa de concentração de 10-150 μg/mL. Ambos procedimentos foram validados com base nos parâmetros de especificidade, linearidade, precisão, exatidão, robustez e limite de quantificação, bem como limite de detecção, avaliado na validação do método cromatográfico. Os métodos foram aplicados na avaliação de potência de rhEPO alfa e beta em produtos farmacêuticos e estudou-se a correlação entre os métodos. Demonstrou-se que as análises dos produtos farmacêuticos forneceram diferenças médias de potência 11,2 % superiores para o CL-FR. Desse modo, estabeleceu-se alternativa no contexto da substituição do uso de animais, contribuindo para aprimorar o controle da qualidade, garantindo a segurança e eficácia terapêutica do produto biológico.application/pdfporUniversidade Federal de Santa MariaPrograma de Pós-Graduação em Ciências FarmacêuticasUFSMBRFarmáciaEritropoietina humana recombinanteCromatografia líquidaValidaçãoEnsaio biológicoCamundongos normocitêmicosReticulócitosRecombinant human erythropoietinLiquid chromatographyValidationBioassayNormocythaemic miceReticulocytesCNPQ::CIENCIAS DA SAUDE::FARMACIADesenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológicoDevelopment and validation of chromatographic method for the potency assessment of recombinant human erythropoietin. Correlation with the biological assayinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisDalmora, Sergio Luizhttp://lattes.cnpq.br/4505166045049607Ribera, Maria TeresaBasso, Luiz Augustohttp://lattes.cnpq.br/3431777523511296http://lattes.cnpq.br/2954810429809063Barth, Thiago201000000000400500300300300c5c3d2e7-af0f-4f36-b006-046daf37340aaf8d3a9f-09fe-427e-82f7-dc050cc03b5f4e72211c-0130-40c0-b2f3-8995b571f906e98ee066-7305-44da-a82c-5692c322e3b0info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações do UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSMORIGINALthiago barth.pdfapplication/pdf6161061http://repositorio.ufsm.br/bitstream/1/5994/1/thiago%20barth.pdf9edc6d5b8eb13e8f8e730f266867810cMD51TEXTthiago barth.pdf.txtthiago barth.pdf.txtExtracted texttext/plain118446http://repositorio.ufsm.br/bitstream/1/5994/2/thiago%20barth.pdf.txtecdac05f337b87fb80025dbb103f8bb1MD52THUMBNAILthiago barth.pdf.jpgthiago barth.pdf.jpgIM Thumbnailimage/jpeg5018http://repositorio.ufsm.br/bitstream/1/5994/3/thiago%20barth.pdf.jpgf25b7dc5b5c70dd72280fe81d83d5910MD531/59942022-10-10 14:18:37.479oai:repositorio.ufsm.br:1/5994Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2022-10-10T17:18:37Biblioteca Digital de Teses e Dissertações do UFSM - Universidade Federal de Santa Maria (UFSM)false |
dc.title.por.fl_str_mv |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico |
dc.title.alternative.eng.fl_str_mv |
Development and validation of chromatographic method for the potency assessment of recombinant human erythropoietin. Correlation with the biological assay |
title |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico |
spellingShingle |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico Barth, Thiago Eritropoietina humana recombinante Cromatografia líquida Validação Ensaio biológico Camundongos normocitêmicos Reticulócitos Recombinant human erythropoietin Liquid chromatography Validation Bioassay Normocythaemic mice Reticulocytes CNPQ::CIENCIAS DA SAUDE::FARMACIA |
title_short |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico |
title_full |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico |
title_fullStr |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico |
title_full_unstemmed |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico |
title_sort |
Desenvolvimento e validação de método cromatográfico para avaliação de potência de eritropoietina humana recombinante. Correlação com o ensaio biológico |
author |
Barth, Thiago |
author_facet |
Barth, Thiago |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Dalmora, Sergio Luiz |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/4505166045049607 |
dc.contributor.referee1.fl_str_mv |
Ribera, Maria Teresa |
dc.contributor.referee2.fl_str_mv |
Basso, Luiz Augusto |
dc.contributor.referee2Lattes.fl_str_mv |
http://lattes.cnpq.br/3431777523511296 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/2954810429809063 |
dc.contributor.author.fl_str_mv |
Barth, Thiago |
contributor_str_mv |
Dalmora, Sergio Luiz Ribera, Maria Teresa Basso, Luiz Augusto |
dc.subject.por.fl_str_mv |
Eritropoietina humana recombinante Cromatografia líquida Validação Ensaio biológico Camundongos normocitêmicos Reticulócitos |
topic |
Eritropoietina humana recombinante Cromatografia líquida Validação Ensaio biológico Camundongos normocitêmicos Reticulócitos Recombinant human erythropoietin Liquid chromatography Validation Bioassay Normocythaemic mice Reticulocytes CNPQ::CIENCIAS DA SAUDE::FARMACIA |
dc.subject.eng.fl_str_mv |
Recombinant human erythropoietin Liquid chromatography Validation Bioassay Normocythaemic mice Reticulocytes |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS DA SAUDE::FARMACIA |
description |
Erythropoietin is a glycoprotein which stimulates the erythropoiesis, clinically used for the treatment of renal anaemia. The biological and chromatographic methods for the potency evaluation of recombinant human erythropoietin (rhEPO) in pharmaceutical products were validated in the present work. The normocythaemic mice bioassay was carried out in female BALB/c strain, with multiple injections schedule and reticulocytes counted by automated flow cytometry. The dose-response curve was linear (r2=0.9708) in the concentration range of 1 to 64 IU/mL. A reversed-phase liquid chromatography method (RP-LC) was developed and validated using a Jupiter C4 column (250 mm x 4.6 mm), maintained at ambient temperature (25°C). The mobile phase A consisted of 0.1% trifluoroacetic acid (TFA) and mobile phase B consisted of 0.08% TFA:acetonitrile (30:70, v/v), run in linear gradient: 0.1-60 min, 0.1-100% of B at flow rate of 0.5 mL/min with detection at 280 nm. The chromatographic separation was obtained within 60 min and it was linear (r2=0.9997) in the concentration range of 10-150 μg/mL. The procedures were validated evaluating parameters such as, the specificity, linearity, precision, accuracy, robustness, and limit of quantitation, as well as, the limit of detection evaluated in the validation of the chromatographic method. The methods were applied for the potency evaluation of the alfa and beta rhEPO in pharmaceutical products, which were analysed by the chromatographic method and compared to the bioassay showing mean differences between the estimated potencies of 11.2% higher for the RP-LC. The alternative established represents a contribution towards the replacement of the animals improving the quality control and assuring the safety and efficacy of the biological product. |
publishDate |
2007 |
dc.date.accessioned.fl_str_mv |
2007-05-25 |
dc.date.available.fl_str_mv |
2007-05-25 |
dc.date.issued.fl_str_mv |
2007-04-10 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
BARTH, Thiago. Development and validation of chromatographic method for the potency assessment of recombinant human erythropoietin. Correlation with the biological assay. 2007. 88 f. Dissertação (Mestrado em Farmacologia) - Universidade Federal de Santa Maria, Santa Maria, 2007. |
dc.identifier.uri.fl_str_mv |
http://repositorio.ufsm.br/handle/1/5994 |
identifier_str_mv |
BARTH, Thiago. Development and validation of chromatographic method for the potency assessment of recombinant human erythropoietin. Correlation with the biological assay. 2007. 88 f. Dissertação (Mestrado em Farmacologia) - Universidade Federal de Santa Maria, Santa Maria, 2007. |
url |
http://repositorio.ufsm.br/handle/1/5994 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.cnpq.fl_str_mv |
201000000000 |
dc.relation.confidence.fl_str_mv |
400 500 300 300 300 |
dc.relation.authority.fl_str_mv |
c5c3d2e7-af0f-4f36-b006-046daf37340a af8d3a9f-09fe-427e-82f7-dc050cc03b5f 4e72211c-0130-40c0-b2f3-8995b571f906 e98ee066-7305-44da-a82c-5692c322e3b0 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Santa Maria |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Ciências Farmacêuticas |
dc.publisher.initials.fl_str_mv |
UFSM |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Farmácia |
publisher.none.fl_str_mv |
Universidade Federal de Santa Maria |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações do UFSM instname:Universidade Federal de Santa Maria (UFSM) instacron:UFSM |
instname_str |
Universidade Federal de Santa Maria (UFSM) |
instacron_str |
UFSM |
institution |
UFSM |
reponame_str |
Biblioteca Digital de Teses e Dissertações do UFSM |
collection |
Biblioteca Digital de Teses e Dissertações do UFSM |
bitstream.url.fl_str_mv |
http://repositorio.ufsm.br/bitstream/1/5994/1/thiago%20barth.pdf http://repositorio.ufsm.br/bitstream/1/5994/2/thiago%20barth.pdf.txt http://repositorio.ufsm.br/bitstream/1/5994/3/thiago%20barth.pdf.jpg |
bitstream.checksum.fl_str_mv |
9edc6d5b8eb13e8f8e730f266867810c ecdac05f337b87fb80025dbb103f8bb1 f25b7dc5b5c70dd72280fe81d83d5910 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações do UFSM - Universidade Federal de Santa Maria (UFSM) |
repository.mail.fl_str_mv |
atendimento.sib@ufsm.br||tedebc@gmail.com |
_version_ |
1801485354565369856 |