Simulated cup/disc ratio: a tool for ophthalmologists

Detalhes bibliográficos
Autor(a) principal: Barbosa, Carolina Pelegrini [UNIFESP]
Data de Publicação: 2010
Outros Autores: Angelini, Pedro Felipe, Schor, Paulo [UNIFESP], Paranhos Junior, Augusto [UNIFESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNIFESP
Texto Completo: http://dx.doi.org/10.1590/S0004-27492010000400003
http://repositorio.unifesp.br/handle/11600/5835
Resumo: PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.
id UFSP_5ed7421e845bfbc101da1fd5e6b019e2
oai_identifier_str oai:repositorio.unifesp.br/:11600/5835
network_acronym_str UFSP
network_name_str Repositório Institucional da UNIFESP
repository_id_str 3465
spelling Simulated cup/disc ratio: a tool for ophthalmologistsRazão escavação/disco simulada: uma ferramenta para oftalmologistasOptic discGlaucomaOptic nerve diseasesDiagnostic techniques, ophthalmologicalInternetMeasuresDisco ópticoGlaucomaDoenças do nervo ópticoTécnicas de diagnóstico oftalmológicoInternetMedidasPURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.OBJETIVO: Avaliar e comparar a habilidade de observadores em medir a razão escavação/disco (CDR) por meio de figuras esquemáticas. MÉTODOS: Em um estudo prospectivo, randomizado e mascarado, 43 imagens representado CDR horizontais e verticais entre 0,2 e 0,9 foram desenvolvidas e apresentadas em uma tela de computador para 171 participantes. RESULTADOS: Para todos os intervalos de CDR a concordância foi satisfatória para análise kappa (0,755 e 0,730 para CDR horizontais e verticais, respectivamente) e para concordância de Lin (R=0,88 e R=0,86 para medidas horizontais e verticais respectivamente). No entanto, a concordância foi fraca para valores intermediários de CDR. A pior concordância ocorreu para CDR horizontais e verticais entre 0,4 e 0,6. CONCLUSÃO: Apesar da boa concordância geral entre as respostas corretas e as respostas dadas pelos participantes, a concordância absoluta para valores intermediários de CDR mostrou-se muito fraca tanto para figuras horizontais como verticais.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Ophthalmology DepartmentUniversidade de São Paulo Escola PolitécnicaUNIFESP, EPM, Ophthalmology DepartmentSciELOConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Conselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Universidade de São Paulo (USP)Barbosa, Carolina Pelegrini [UNIFESP]Angelini, Pedro FelipeSchor, Paulo [UNIFESP]Paranhos Junior, Augusto [UNIFESP]2015-06-14T13:41:47Z2015-06-14T13:41:47Z2010-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion320-322application/pdfhttp://dx.doi.org/10.1590/S0004-27492010000400003Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 73, n. 4, p. 320-322, 2010.10.1590/S0004-27492010000400003S0004-27492010000400003.pdf0004-2749S0004-27492010000400003http://repositorio.unifesp.br/handle/11600/5835engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-05T00:28:31Zoai:repositorio.unifesp.br/:11600/5835Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-05T00:28:31Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false
dc.title.none.fl_str_mv Simulated cup/disc ratio: a tool for ophthalmologists
Razão escavação/disco simulada: uma ferramenta para oftalmologistas
title Simulated cup/disc ratio: a tool for ophthalmologists
spellingShingle Simulated cup/disc ratio: a tool for ophthalmologists
Barbosa, Carolina Pelegrini [UNIFESP]
Optic disc
Glaucoma
Optic nerve diseases
Diagnostic techniques, ophthalmological
Internet
Measures
Disco óptico
Glaucoma
Doenças do nervo óptico
Técnicas de diagnóstico oftalmológico
Internet
Medidas
title_short Simulated cup/disc ratio: a tool for ophthalmologists
title_full Simulated cup/disc ratio: a tool for ophthalmologists
title_fullStr Simulated cup/disc ratio: a tool for ophthalmologists
title_full_unstemmed Simulated cup/disc ratio: a tool for ophthalmologists
title_sort Simulated cup/disc ratio: a tool for ophthalmologists
author Barbosa, Carolina Pelegrini [UNIFESP]
author_facet Barbosa, Carolina Pelegrini [UNIFESP]
Angelini, Pedro Felipe
Schor, Paulo [UNIFESP]
Paranhos Junior, Augusto [UNIFESP]
author_role author
author2 Angelini, Pedro Felipe
Schor, Paulo [UNIFESP]
Paranhos Junior, Augusto [UNIFESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Federal de São Paulo (UNIFESP)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Barbosa, Carolina Pelegrini [UNIFESP]
Angelini, Pedro Felipe
Schor, Paulo [UNIFESP]
Paranhos Junior, Augusto [UNIFESP]
dc.subject.por.fl_str_mv Optic disc
Glaucoma
Optic nerve diseases
Diagnostic techniques, ophthalmological
Internet
Measures
Disco óptico
Glaucoma
Doenças do nervo óptico
Técnicas de diagnóstico oftalmológico
Internet
Medidas
topic Optic disc
Glaucoma
Optic nerve diseases
Diagnostic techniques, ophthalmological
Internet
Measures
Disco óptico
Glaucoma
Doenças do nervo óptico
Técnicas de diagnóstico oftalmológico
Internet
Medidas
description PURPOSE: To evaluate and compare the observers' ability to measure simulations of cup/disc ratios (CDR) as concentric and non-concentric circles. METHODS: In a prospective, random, and masked setting, 43 images representing the CDR spectrum from 0.2 to 0.9 for vertical and horizontal CDR measurements were developed and presented on a computer screen to 171 participants. RESULTS: There were satisfactory agreements according to the kappa coefficient (0.755 and 0.730 for horizontal and vertical cup disc ratios, respectively) and Lin's concordance correlation (R=0.88 and R=0.86 for horizontal and vertical measurements, respectively). However, very poor agreement was found for intermediate CDR values. The worst agreement occurred when the CDR was between 0.4 and 0.6 for both the horizontal and vertical values. The kappa coefficient was 0.37 and 0.39 for 0.4 CDR (horizontal and vertical, respectively), 0.39 and 0.38 for 0.5 CDR (horizontal and vertical, respectively) and 0.45 and 0.41 for 0.6 CDR (horizontal and vertical, respectively). CONCLUSION: Despite a good general agreement between the gold standard and the participants' responses, the absolute agreement for intermediate CDR values was very poor for both horizontal and vertical values.
publishDate 2010
dc.date.none.fl_str_mv 2010-08-01
2015-06-14T13:41:47Z
2015-06-14T13:41:47Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0004-27492010000400003
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 73, n. 4, p. 320-322, 2010.
10.1590/S0004-27492010000400003
S0004-27492010000400003.pdf
0004-2749
S0004-27492010000400003
http://repositorio.unifesp.br/handle/11600/5835
url http://dx.doi.org/10.1590/S0004-27492010000400003
http://repositorio.unifesp.br/handle/11600/5835
identifier_str_mv Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 73, n. 4, p. 320-322, 2010.
10.1590/S0004-27492010000400003
S0004-27492010000400003.pdf
0004-2749
S0004-27492010000400003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Arquivos Brasileiros de Oftalmologia
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 320-322
application/pdf
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UNIFESP
instname:Universidade Federal de São Paulo (UNIFESP)
instacron:UNIFESP
instname_str Universidade Federal de São Paulo (UNIFESP)
instacron_str UNIFESP
institution UNIFESP
reponame_str Repositório Institucional da UNIFESP
collection Repositório Institucional da UNIFESP
repository.name.fl_str_mv Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)
repository.mail.fl_str_mv biblioteca.csp@unifesp.br
_version_ 1814268453590138880