Continuous Wavelet Transform study for normal and ictal eeg signals analysis

Detalhes bibliográficos
Autor(a) principal: Silva, Thiago Bastos da
Data de Publicação: 2023
Outros Autores: Campos, Sílvia Mara da Costa
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista de Engenharia Química e Química
Texto Completo: https://periodicos.ufv.br/jcec/article/view/15427
Resumo: In this article we propose the use of the continuous wavelet transform to analyze some specific signals acquired via electroencelalogram (EEG).  The EEG is a widely used test to analyze the brain electrical activity and, through it, it is possible to detect, in certain frequency bands, if this electrical activity is in accordance with the established norms. To achieve this goal, we will first explain a little about how the EEG works and then use the continuous wavelet transform, through a program written in python language, to analyze the behavior of EEG signals in the time and frequency domains. There are two specific types of signals studied: from healthy people and from people in epileptic seizures, known as ictal signals.  Signals from a consolidated database of the University of Bonn were used.  The main results were statistical data obtained from the signals and their respective scalograms, in which the difference between the maximum values, mean values, and other parameters of each signal and scalogram were compared.
id UFV-4_e16b334de7a5ac403c989c47cf858976
oai_identifier_str oai:ojs.periodicos.ufv.br:article/15427
network_acronym_str UFV-4
network_name_str Revista de Engenharia Química e Química
repository_id_str
spelling Continuous Wavelet Transform study for normal and ictal eeg signals analysis Estudo da Transformada Wavelet Contínua para análise de sinais EEG normais e ictaisEEGContinuous Wavelet TransformSignalScalogramEEGSinalEscalogramaTransformadas Wavelet contínuasIn this article we propose the use of the continuous wavelet transform to analyze some specific signals acquired via electroencelalogram (EEG).  The EEG is a widely used test to analyze the brain electrical activity and, through it, it is possible to detect, in certain frequency bands, if this electrical activity is in accordance with the established norms. To achieve this goal, we will first explain a little about how the EEG works and then use the continuous wavelet transform, through a program written in python language, to analyze the behavior of EEG signals in the time and frequency domains. There are two specific types of signals studied: from healthy people and from people in epileptic seizures, known as ictal signals.  Signals from a consolidated database of the University of Bonn were used.  The main results were statistical data obtained from the signals and their respective scalograms, in which the difference between the maximum values, mean values, and other parameters of each signal and scalogram were compared.Neste artigo propomos o uso da transformada wavelet continua para analisar alguns sinais específicos obtidos via eletroencelalograma (EEG).  O EEG é um exame muito utilizado para análise da atividade elétrica cerebral e, através dele, é possível detectar, em determinadas bandas de frequência, se essa atividade elétrica está de acordo com as normas estabelecidas. Para atingir este objetivo, primeiramente explicaremos um pouco sobre o funcionamento do EEG e depois utilizaremos a transformada wavelet contínua, por meio de um programa escrito na linguagem python, para analisar o comportamento de sinais de EEG  nos domínios do tempo e da frequência. São dois tipos específicos de sinais  estudados: de pessoas saudáveis e de pessoas em crise epiléptica, conhecidos como sinais ictais.  Foram utilizados sinais de uma base de dados consolidada da Universidade de Bonn.  Os principais resultados foram a obtenção dos dados estatísticos obtidos dos sinais e de seus respectivos escalogramas, em que foram comparados a diferença entre os valores máximos, média de valores e outros parâmetros de cada sinal e escalograma.Universidade Federal de Viçosa - UFV2023-02-20info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtigo, Manuscrito, Eventosapplication/pdfhttps://periodicos.ufv.br/jcec/article/view/1542710.18540/jcecvl9iss1pp15427-01eThe Journal of Engineering and Exact Sciences; Vol. 9 No. 1 (2023); 15427-01eThe Journal of Engineering and Exact Sciences; Vol. 9 Núm. 1 (2023); 15427-01eThe Journal of Engineering and Exact Sciences; v. 9 n. 1 (2023); 15427-01e2527-1075reponame:Revista de Engenharia Química e Químicainstname:Universidade Federal de Viçosa (UFV)instacron:UFVporhttps://periodicos.ufv.br/jcec/article/view/15427/7834Copyright (c) 2023 The Journal of Engineering and Exact Scienceshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessSilva, Thiago Bastos daCampos, Sílvia Mara da Costa2023-02-24T18:44:16Zoai:ojs.periodicos.ufv.br:article/15427Revistahttp://www.seer.ufv.br/seer/rbeq2/index.php/req2/indexONGhttps://periodicos.ufv.br/jcec/oaijcec.journal@ufv.br||req2@ufv.br2446-94162446-9416opendoar:2023-02-24T18:44:16Revista de Engenharia Química e Química - Universidade Federal de Viçosa (UFV)false
dc.title.none.fl_str_mv Continuous Wavelet Transform study for normal and ictal eeg signals analysis
Estudo da Transformada Wavelet Contínua para análise de sinais EEG normais e ictais
title Continuous Wavelet Transform study for normal and ictal eeg signals analysis
spellingShingle Continuous Wavelet Transform study for normal and ictal eeg signals analysis
Silva, Thiago Bastos da
EEG
Continuous Wavelet Transform
Signal
Scalogram
EEG
Sinal
Escalograma
Transformadas Wavelet contínuas
title_short Continuous Wavelet Transform study for normal and ictal eeg signals analysis
title_full Continuous Wavelet Transform study for normal and ictal eeg signals analysis
title_fullStr Continuous Wavelet Transform study for normal and ictal eeg signals analysis
title_full_unstemmed Continuous Wavelet Transform study for normal and ictal eeg signals analysis
title_sort Continuous Wavelet Transform study for normal and ictal eeg signals analysis
author Silva, Thiago Bastos da
author_facet Silva, Thiago Bastos da
Campos, Sílvia Mara da Costa
author_role author
author2 Campos, Sílvia Mara da Costa
author2_role author
dc.contributor.author.fl_str_mv Silva, Thiago Bastos da
Campos, Sílvia Mara da Costa
dc.subject.por.fl_str_mv EEG
Continuous Wavelet Transform
Signal
Scalogram
EEG
Sinal
Escalograma
Transformadas Wavelet contínuas
topic EEG
Continuous Wavelet Transform
Signal
Scalogram
EEG
Sinal
Escalograma
Transformadas Wavelet contínuas
description In this article we propose the use of the continuous wavelet transform to analyze some specific signals acquired via electroencelalogram (EEG).  The EEG is a widely used test to analyze the brain electrical activity and, through it, it is possible to detect, in certain frequency bands, if this electrical activity is in accordance with the established norms. To achieve this goal, we will first explain a little about how the EEG works and then use the continuous wavelet transform, through a program written in python language, to analyze the behavior of EEG signals in the time and frequency domains. There are two specific types of signals studied: from healthy people and from people in epileptic seizures, known as ictal signals.  Signals from a consolidated database of the University of Bonn were used.  The main results were statistical data obtained from the signals and their respective scalograms, in which the difference between the maximum values, mean values, and other parameters of each signal and scalogram were compared.
publishDate 2023
dc.date.none.fl_str_mv 2023-02-20
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artigo, Manuscrito, Eventos
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufv.br/jcec/article/view/15427
10.18540/jcecvl9iss1pp15427-01e
url https://periodicos.ufv.br/jcec/article/view/15427
identifier_str_mv 10.18540/jcecvl9iss1pp15427-01e
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.ufv.br/jcec/article/view/15427/7834
dc.rights.driver.fl_str_mv Copyright (c) 2023 The Journal of Engineering and Exact Sciences
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2023 The Journal of Engineering and Exact Sciences
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Viçosa - UFV
publisher.none.fl_str_mv Universidade Federal de Viçosa - UFV
dc.source.none.fl_str_mv The Journal of Engineering and Exact Sciences; Vol. 9 No. 1 (2023); 15427-01e
The Journal of Engineering and Exact Sciences; Vol. 9 Núm. 1 (2023); 15427-01e
The Journal of Engineering and Exact Sciences; v. 9 n. 1 (2023); 15427-01e
2527-1075
reponame:Revista de Engenharia Química e Química
instname:Universidade Federal de Viçosa (UFV)
instacron:UFV
instname_str Universidade Federal de Viçosa (UFV)
instacron_str UFV
institution UFV
reponame_str Revista de Engenharia Química e Química
collection Revista de Engenharia Química e Química
repository.name.fl_str_mv Revista de Engenharia Química e Química - Universidade Federal de Viçosa (UFV)
repository.mail.fl_str_mv jcec.journal@ufv.br||req2@ufv.br
_version_ 1800211186196676608