Fast determination of minoxidil by photometric flow titration

Detalhes bibliográficos
Autor(a) principal: Sousa,R. A. de
Data de Publicação: 2005
Outros Autores: Semaan,F. S., Baio,J. A. F., Cavalheiro,E. T. G.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Eclética Química
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000300010
Resumo: A photometric flow titration based on the redox reaction between KMnO4 and minoxidil is described. The best titration results were observed at 3.20 x 10-4 mol L-1 KMnO4 and 1.00 x 10-3 mol L-1 minoxidil, using the minoxidil solutions as titrant. The flow rate was fixed at 17 mL min-1 and the titrant was added to the system in aliquots of 500 µL, the color changes were monitored at 550 nm. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.6 to 102.8 % were observed depending on the sample. Comparison with the chromatographic procedure reveled relative errors of 3.5 - 4.0 %.
id UNESP-29_8e14d621e6682305dfe8b73e2350d409
oai_identifier_str oai:scielo:S0100-46702005000300010
network_acronym_str UNESP-29
network_name_str Eclética Química
repository_id_str
spelling Fast determination of minoxidil by photometric flow titrationminoxidil determinationphotometric titrationflow titrationA photometric flow titration based on the redox reaction between KMnO4 and minoxidil is described. The best titration results were observed at 3.20 x 10-4 mol L-1 KMnO4 and 1.00 x 10-3 mol L-1 minoxidil, using the minoxidil solutions as titrant. The flow rate was fixed at 17 mL min-1 and the titrant was added to the system in aliquots of 500 µL, the color changes were monitored at 550 nm. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.6 to 102.8 % were observed depending on the sample. Comparison with the chromatographic procedure reveled relative errors of 3.5 - 4.0 %.Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP2005-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000300010Eclética Química v.30 n.3 2005reponame:Eclética Químicainstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESP10.1590/S0100-46702005000300010info:eu-repo/semantics/openAccessSousa,R. A. deSemaan,F. S.Baio,J. A. F.Cavalheiro,E. T. G.eng2005-11-17T00:00:00Zoai:scielo:S0100-46702005000300010Revistahttp://revista.iq.unesp.br/ojs/index.php/ecletica/PUBhttps://revista.iq.unesp.br/ojs/index.php/ecletica/oaiecletica@ctrlk.com.br||ecletica@iq.unesp.br1678-46181678-4618opendoar:2005-11-17T00:00Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)false
dc.title.none.fl_str_mv Fast determination of minoxidil by photometric flow titration
title Fast determination of minoxidil by photometric flow titration
spellingShingle Fast determination of minoxidil by photometric flow titration
Sousa,R. A. de
minoxidil determination
photometric titration
flow titration
title_short Fast determination of minoxidil by photometric flow titration
title_full Fast determination of minoxidil by photometric flow titration
title_fullStr Fast determination of minoxidil by photometric flow titration
title_full_unstemmed Fast determination of minoxidil by photometric flow titration
title_sort Fast determination of minoxidil by photometric flow titration
author Sousa,R. A. de
author_facet Sousa,R. A. de
Semaan,F. S.
Baio,J. A. F.
Cavalheiro,E. T. G.
author_role author
author2 Semaan,F. S.
Baio,J. A. F.
Cavalheiro,E. T. G.
author2_role author
author
author
dc.contributor.author.fl_str_mv Sousa,R. A. de
Semaan,F. S.
Baio,J. A. F.
Cavalheiro,E. T. G.
dc.subject.por.fl_str_mv minoxidil determination
photometric titration
flow titration
topic minoxidil determination
photometric titration
flow titration
description A photometric flow titration based on the redox reaction between KMnO4 and minoxidil is described. The best titration results were observed at 3.20 x 10-4 mol L-1 KMnO4 and 1.00 x 10-3 mol L-1 minoxidil, using the minoxidil solutions as titrant. The flow rate was fixed at 17 mL min-1 and the titrant was added to the system in aliquots of 500 µL, the color changes were monitored at 550 nm. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.6 to 102.8 % were observed depending on the sample. Comparison with the chromatographic procedure reveled relative errors of 3.5 - 4.0 %.
publishDate 2005
dc.date.none.fl_str_mv 2005-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000300010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000300010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-46702005000300010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP
publisher.none.fl_str_mv Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP
dc.source.none.fl_str_mv Eclética Química v.30 n.3 2005
reponame:Eclética Química
instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Eclética Química
collection Eclética Química
repository.name.fl_str_mv Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
repository.mail.fl_str_mv ecletica@ctrlk.com.br||ecletica@iq.unesp.br
_version_ 1754734617721569280