Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood

Detalhes bibliográficos
Autor(a) principal: Silvério, Alessandra Cristina Pupin
Data de Publicação: 2021
Outros Autores: Machado, Simone Caetani, Silva, Vanessa Caroline Cardoso, Rodrigues, Estéfane, Martins, Isarita
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/18859
Resumo: To determine the percentages of carboxyhaemoglobin (COHb) and methaemoglobin (MeHb) in donor blood and to compare these levels between smokers and nonsmokers at different time points during blood storage. Blood donors were recruited from Haematology Service, University Hospital Alzira Velano, Alfenas-MG. The blood was kept in collecting ducts (noodles) containing citrate, phosphate and dextrose (CPD) and stored at 4°C throughout the storage period. Since the noodles kept the characteristics of the bags, COHb and MeHb levels were analysed on the day of donation and after 20 days of storage. Levels of COHb and MeHb were determined using spectrophotometric methods. Non-parametric Friedman and Mann-Whitney tests were employed to compare COHb and MeHb levels before and after the storage and groups of smokers and nonsmokers, respectively. Levels of COHb and MeHb in the blood collected from smokers and nonsmokers were statistically different (p< 0.05; Mann- Whitney test) when the samples were analyzed before the storage. In blood of smokers, COHb levels were no different over a 20-day storage period (p= 0.7009; Friedman test). On the other hand, MeHb levels were significant different over a 20-day storage period (p< 0.05). The results suggest the need to regularly assess COHb and MeHb levels in donor blood stored in blood banks.
id UNIFEI_51e3cef728e7394cccdc7cacf9bfc210
oai_identifier_str oai:ojs.pkp.sfu.ca:article/18859
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Determination of carboxyhaemoglobin and methaemoglobin levels in donated bloodDeterminación de los niveles de carboxhemoglobina y metahemoglobina en sangre donada Determinação dos níveis de carboxihemoglobina e metahemoglobina no sangue doadoBlood bagCarboxyhaemoglobinMethaemoglobinStorage period.Bolsa de sangreCarboxihemoglobinaMetahemoglobinaPeriodo de almacenamiento.Bolsa de sangueCarboxihemoglobinaMetahemoglobinaPeríodo de armazenamento.To determine the percentages of carboxyhaemoglobin (COHb) and methaemoglobin (MeHb) in donor blood and to compare these levels between smokers and nonsmokers at different time points during blood storage. Blood donors were recruited from Haematology Service, University Hospital Alzira Velano, Alfenas-MG. The blood was kept in collecting ducts (noodles) containing citrate, phosphate and dextrose (CPD) and stored at 4°C throughout the storage period. Since the noodles kept the characteristics of the bags, COHb and MeHb levels were analysed on the day of donation and after 20 days of storage. Levels of COHb and MeHb were determined using spectrophotometric methods. Non-parametric Friedman and Mann-Whitney tests were employed to compare COHb and MeHb levels before and after the storage and groups of smokers and nonsmokers, respectively. Levels of COHb and MeHb in the blood collected from smokers and nonsmokers were statistically different (p< 0.05; Mann- Whitney test) when the samples were analyzed before the storage. In blood of smokers, COHb levels were no different over a 20-day storage period (p= 0.7009; Friedman test). On the other hand, MeHb levels were significant different over a 20-day storage period (p< 0.05). The results suggest the need to regularly assess COHb and MeHb levels in donor blood stored in blood banks.Determine los porcentajes de carboxihemoglobina (COHb) y metahemoglobina (MeHb) en la sangre de los donantes y compare estos niveles entre fumadores y no fumadores en diferentes momentos durante el almacenamiento de sangre. Los donantes de sangre fueron reclutados en el Servicio de Hematología del Hospital Universitario Alzira Velano, Alfenas-MG. La sangre se mantuvo en conductos colectores (macarrones) que contenían citrato, fosfato y dextrosa (CPD) y se almacenó a 4 ° C durante todo el período de almacenamiento. Como los fideos mantuvieron las características de las bolsas, se analizaron los niveles de COHb y MeHb el día de la donación y después de 20 días de almacenamiento. Los niveles de COHb y MeHb se determinaron mediante métodos espectrofotométricos. Se utilizaron pruebas no paramétricas de Friedman y Mann-Whitney para comparar los niveles de COHb y MeHb antes y después del almacenamiento y los grupos de fumadores y no fumadores, respectivamente. Los niveles de COHb y MeHb en sangre extraída de fumadores y no fumadores fueron estadísticamente diferentes (p <0,05; prueba de Mann-Whitney) cuando las muestras se analizaron antes del almacenamiento. En la sangre de los fumadores, los niveles de COHb no fueron diferentes durante un período de almacenamiento de 20 días (p = 0,7009; prueba de Friedman). Por otro lado, los niveles de MeHb fueron significativamente diferentes durante un período de almacenamiento de 20 días (p <0,05). Los resultados sugieren la necesidad de evaluar periódicamente los niveles de COHb y MeHb en sangre de donantes almacenada en bancos de sangre.Determinar as porcentagens de carboxihemoglobina (COHb) e metahemoglobina (MeHb) no sangue de doadores e comparar esses níveis entre fumantes e não fumantes em diferentes momentos durante o armazenamento de sangue. Os doadores de sangue foram recrutados no Serviço de Hematologia do Hospital Universitário Alzira Velano, Alfenas-MG. O sangue foi mantido em dutos coletores (macarrão) contendo citrato, fosfato e dextrose (CPD) e armazenado a 4 ° C durante todo o período de armazenamento. Como o macarrão manteve as características das sacolas, os níveis de COHb e MeHb foram analisados ​​no dia da doação e após 20 dias de armazenamento. Os níveis de COHb e MeHb foram determinados usando métodos espectrofotométricos. Os testes não paramétricos de Friedman e Mann-Whitney foram empregados para comparar os níveis de COHb e MeHb antes e após o armazenamento e grupos de fumantes e não fumantes, respectivamente. Os níveis de COHb e MeHb no sangue coletado de fumantes e não fumantes foram estatisticamente diferentes (p <0,05; teste de Mann-Whitney) quando as amostras foram analisadas antes do armazenamento. No sangue de fumantes, os níveis de COHb não foram diferentes ao longo de um período de armazenamento de 20 dias (p = 0,7009; teste de Friedman). Por outro lado, os níveis de MeHb foram significativamente diferentes ao longo de um período de armazenamento de 20 dias (p <0,05). Os resultados sugerem a necessidade de avaliar regularmente os níveis de COHb e MeHb no sangue de doadores armazenado em bancos de sangue.Research, Society and Development2021-08-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1885910.33448/rsd-v10i10.18859Research, Society and Development; Vol. 10 No. 10; e294101018859Research, Society and Development; Vol. 10 Núm. 10; e294101018859Research, Society and Development; v. 10 n. 10; e2941010188592525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/18859/16848Copyright (c) 2021 Alessandra Cristina Pupin Silvério; Simone Caetani Machado; Vanessa Caroline Cardoso Silva; Estéfane Rodrigues; Isarita Martinshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessSilvério, Alessandra Cristina Pupin Machado, Simone Caetani Silva, Vanessa Caroline Cardoso Rodrigues, EstéfaneMartins, Isarita 2021-10-02T21:49:16Zoai:ojs.pkp.sfu.ca:article/18859Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:38:53.700863Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
Determinación de los niveles de carboxhemoglobina y metahemoglobina en sangre donada
Determinação dos níveis de carboxihemoglobina e metahemoglobina no sangue doado
title Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
spellingShingle Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
Silvério, Alessandra Cristina Pupin
Blood bag
Carboxyhaemoglobin
Methaemoglobin
Storage period.
Bolsa de sangre
Carboxihemoglobina
Metahemoglobina
Periodo de almacenamiento.
Bolsa de sangue
Carboxihemoglobina
Metahemoglobina
Período de armazenamento.
title_short Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
title_full Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
title_fullStr Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
title_full_unstemmed Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
title_sort Determination of carboxyhaemoglobin and methaemoglobin levels in donated blood
author Silvério, Alessandra Cristina Pupin
author_facet Silvério, Alessandra Cristina Pupin
Machado, Simone Caetani
Silva, Vanessa Caroline Cardoso
Rodrigues, Estéfane
Martins, Isarita
author_role author
author2 Machado, Simone Caetani
Silva, Vanessa Caroline Cardoso
Rodrigues, Estéfane
Martins, Isarita
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Silvério, Alessandra Cristina Pupin
Machado, Simone Caetani
Silva, Vanessa Caroline Cardoso
Rodrigues, Estéfane
Martins, Isarita
dc.subject.por.fl_str_mv Blood bag
Carboxyhaemoglobin
Methaemoglobin
Storage period.
Bolsa de sangre
Carboxihemoglobina
Metahemoglobina
Periodo de almacenamiento.
Bolsa de sangue
Carboxihemoglobina
Metahemoglobina
Período de armazenamento.
topic Blood bag
Carboxyhaemoglobin
Methaemoglobin
Storage period.
Bolsa de sangre
Carboxihemoglobina
Metahemoglobina
Periodo de almacenamiento.
Bolsa de sangue
Carboxihemoglobina
Metahemoglobina
Período de armazenamento.
description To determine the percentages of carboxyhaemoglobin (COHb) and methaemoglobin (MeHb) in donor blood and to compare these levels between smokers and nonsmokers at different time points during blood storage. Blood donors were recruited from Haematology Service, University Hospital Alzira Velano, Alfenas-MG. The blood was kept in collecting ducts (noodles) containing citrate, phosphate and dextrose (CPD) and stored at 4°C throughout the storage period. Since the noodles kept the characteristics of the bags, COHb and MeHb levels were analysed on the day of donation and after 20 days of storage. Levels of COHb and MeHb were determined using spectrophotometric methods. Non-parametric Friedman and Mann-Whitney tests were employed to compare COHb and MeHb levels before and after the storage and groups of smokers and nonsmokers, respectively. Levels of COHb and MeHb in the blood collected from smokers and nonsmokers were statistically different (p< 0.05; Mann- Whitney test) when the samples were analyzed before the storage. In blood of smokers, COHb levels were no different over a 20-day storage period (p= 0.7009; Friedman test). On the other hand, MeHb levels were significant different over a 20-day storage period (p< 0.05). The results suggest the need to regularly assess COHb and MeHb levels in donor blood stored in blood banks.
publishDate 2021
dc.date.none.fl_str_mv 2021-08-11
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/18859
10.33448/rsd-v10i10.18859
url https://rsdjournal.org/index.php/rsd/article/view/18859
identifier_str_mv 10.33448/rsd-v10i10.18859
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/18859/16848
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 10; e294101018859
Research, Society and Development; Vol. 10 Núm. 10; e294101018859
Research, Society and Development; v. 10 n. 10; e294101018859
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052686071234560