Resumo: This study aimed to assess the reproducibility of linear measurements performed in dental models produced via intraoral scanning and three-dimensional (3D) printing using digital light processing (DLP) and fused deposition modeling (FDM). A sample of 22 participants was selected for this study. Intraoral scanning was performed in each participant with TRIOS™ (3Shape A/S™, Copenhagen, Denmark) device. The digital models were 3D printed using DLP and FDM techniques. Using a caliper, intraoral linear measurements were performed in situ (on the surface of participant’s teeth) and on the 3D printed models. The measurements taken intraoral and on the models were compared using the Intraclass Correlation Coefficient (ICC). The correlation between measurements taken in situ and on DLP models was poor (<0.4), while between in situ and FDM it ranged from poor to satisfactory (<0.75). Generalized linear model showed that the differences did not reach statistically significant levels (p>0.05). According to Bland-Altman approach, the size of measurements did not bias the outcomes. The intraoral scanning and 3D printing techniques used in this study enabled the reproducibility of linear measurements, however, discrete distortions that might be clinically significant occurred.
id UNIFEI_d49a60687b4bd812c6ee33ea378e2a50
oai_identifier_str oai:ojs.pkp.sfu.ca:article/13370
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Reproducibility of linear measurements performed in dental models from 3D printingReproducibilidad de medidas lineales realizadas en modelos dentales a partir de impresión 3DReprodutibilidade de medições lineares realizadas em modelos odontológicos provenientes de impressão 3DDental modelsIntraoral scanningImagingThree-dimensional printing.Modelos dentalesExploración intraoralImágenesImpresión tridimensional.Modelos odontológicosEscaneamento intraoralImaginologiaImpressão 3D.This study aimed to assess the reproducibility of linear measurements performed in dental models produced via intraoral scanning and three-dimensional (3D) printing using digital light processing (DLP) and fused deposition modeling (FDM). A sample of 22 participants was selected for this study. Intraoral scanning was performed in each participant with TRIOS™ (3Shape A/S™, Copenhagen, Denmark) device. The digital models were 3D printed using DLP and FDM techniques. Using a caliper, intraoral linear measurements were performed in situ (on the surface of participant’s teeth) and on the 3D printed models. The measurements taken intraoral and on the models were compared using the Intraclass Correlation Coefficient (ICC). The correlation between measurements taken in situ and on DLP models was poor (<0.4), while between in situ and FDM it ranged from poor to satisfactory (<0.75). Generalized linear model showed that the differences did not reach statistically significant levels (p>0.05). According to Bland-Altman approach, the size of measurements did not bias the outcomes. The intraoral scanning and 3D printing techniques used in this study enabled the reproducibility of linear measurements, however, discrete distortions that might be clinically significant occurred.El objetivo fue evaluar la reproducibilidad de las mediciones lineales realizadas en modelos dentales producidos mediante escaneo intraoral e impresión tridimensional (3D) utilizando procesamiento de luz digital (DLP) y modelado de deposición fundida (FDM). Se seleccionó una muestra de 22 participantes para este estudio. Se realizó una exploración intraoral en cada participante con el dispositivo TRIOS ™ (3Shape A / S ™, Copenhague, Dinamarca). Los modelos digitales se imprimieron en 3D utilizando técnicas DLP y FDM. Con un calibre, se realizaron mediciones lineales intraorales in situ (en la superficie de los dientes de los participantes) y en los modelos impresos en 3D. Las medidas tomadas intraoralmente y en los modelos se compararon utilizando el coeficiente de correlación intraclase (ICC). La correlación entre las medidas tomadas in situ y en los modelos DLP fue pobre (<0,4), mientras que entre in situ y FDM varió de mala a satisfactoria (<0,75). El modelo lineal generalizado mostró que las diferencias no alcanzaron niveles estadísticamente significativos (p> 0.05). Según el enfoque de Bland-Altman, el tamaño de las mediciones no sesgó los resultados. Las técnicas de escaneo intraoral e impresión 3D utilizadas en este estudio permitieron la reproducibilidad de las mediciones lineales, sin embargo, se produjeron distorsiones discretas que podrían ser clínicamente significativas.O objetivo deste estudo foi avaliar a reprodutibilidade de medidas lineares realizadas em modelos dentais produzidos por escaneamento intraoral e impressão tridimensional (3D) utilizando processamento digital de luz (DLP) e modelagem por deposição fundida (FDM). Uma amostra de 22 participantes foi selecionada para este estudo. A varredura intraoral foi realizada em cada participante com o dispositivo TRIOS ™ (3Shape A / S ™, Copenhagen, Dinamarca). Os modelos digitais foram impressos em 3D usando técnicas DLP e FDM. Usando um calibrador, medições lineares intraorais foram realizadas in situ (na superfície dos dentes do participante) e nos modelos impressos em 3D. As medições feitas intraoral e nos modelos foram comparadas usando o coeficiente de correlação intraclasse (ICC). A correlação entre as medições feitas in situ e nos modelos DLP foi fraca (<0,4), enquanto entre in situ e FDM variou de fraca a satisfatória (<0,75). O modelo linear generalizado mostrou que as diferenças não atingiram níveis estatisticamente significantes (p> 0,05). De acordo com a abordagem de Bland-Altman, o tamanho das medidas não influenciou os resultados. As técnicas de digitalização intraoral e impressão 3D utilizadas neste estudo possibilitaram a reprodutibilidade das medidas lineares, porém, ocorreram discretas distorções que podem ser clinicamente significativas.Research, Society and Development2021-09-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1337010.33448/rsd-v10i11.13370Research, Society and Development; Vol. 10 No. 11; e344101113370Research, Society and Development; Vol. 10 Núm. 11; e344101113370Research, Society and Development; v. 10 n. 11; e3441011133702525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/13370/17599Copyright (c) 2021 Fernanda Latorre Melgaço Maia; Ademir Franco; Daphne Azambuja Hatschbach de Aquino; Luciana Butini Oliveira; José Luiz Cintra Junqueira; Anne Caroline Costa Oenninghttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessMaia, Fernanda Latorre MelgaçoFranco, AdemirAquino, Daphne Azambuja Hatschbach de Oliveira, Luciana Butini Junqueira, José Luiz Cintra Oenning, Anne Caroline Costa 2021-10-23T19:01:11Zoai:ojs.pkp.sfu.ca:article/13370Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:34:43.693296Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Reproducibility of linear measurements performed in dental models from 3D printing
Reproducibilidad de medidas lineales realizadas en modelos dentales a partir de impresión 3D
Reprodutibilidade de medições lineares realizadas em modelos odontológicos provenientes de impressão 3D
title Reproducibility of linear measurements performed in dental models from 3D printing
spellingShingle Reproducibility of linear measurements performed in dental models from 3D printing
Maia, Fernanda Latorre Melgaço
Dental models
Intraoral scanning
Imaging
Three-dimensional printing.
Modelos dentales
Exploración intraoral
Imágenes
Impresión tridimensional.
Modelos odontológicos
Escaneamento intraoral
Imaginologia
Impressão 3D.
title_short Reproducibility of linear measurements performed in dental models from 3D printing
title_full Reproducibility of linear measurements performed in dental models from 3D printing
title_fullStr Reproducibility of linear measurements performed in dental models from 3D printing
title_full_unstemmed Reproducibility of linear measurements performed in dental models from 3D printing
title_sort Reproducibility of linear measurements performed in dental models from 3D printing
author Maia, Fernanda Latorre Melgaço
author_facet Maia, Fernanda Latorre Melgaço
Franco, Ademir
Aquino, Daphne Azambuja Hatschbach de
Oliveira, Luciana Butini
Junqueira, José Luiz Cintra
Oenning, Anne Caroline Costa
author_role author
author2 Franco, Ademir
Aquino, Daphne Azambuja Hatschbach de
Oliveira, Luciana Butini
Junqueira, José Luiz Cintra
Oenning, Anne Caroline Costa
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Maia, Fernanda Latorre Melgaço
Franco, Ademir
Aquino, Daphne Azambuja Hatschbach de
Oliveira, Luciana Butini
Junqueira, José Luiz Cintra
Oenning, Anne Caroline Costa
dc.subject.por.fl_str_mv Dental models
Intraoral scanning
Imaging
Three-dimensional printing.
Modelos dentales
Exploración intraoral
Imágenes
Impresión tridimensional.
Modelos odontológicos
Escaneamento intraoral
Imaginologia
Impressão 3D.
topic Dental models
Intraoral scanning
Imaging
Three-dimensional printing.
Modelos dentales
Exploración intraoral
Imágenes
Impresión tridimensional.
Modelos odontológicos
Escaneamento intraoral
Imaginologia
Impressão 3D.
description This study aimed to assess the reproducibility of linear measurements performed in dental models produced via intraoral scanning and three-dimensional (3D) printing using digital light processing (DLP) and fused deposition modeling (FDM). A sample of 22 participants was selected for this study. Intraoral scanning was performed in each participant with TRIOS™ (3Shape A/S™, Copenhagen, Denmark) device. The digital models were 3D printed using DLP and FDM techniques. Using a caliper, intraoral linear measurements were performed in situ (on the surface of participant’s teeth) and on the 3D printed models. The measurements taken intraoral and on the models were compared using the Intraclass Correlation Coefficient (ICC). The correlation between measurements taken in situ and on DLP models was poor (<0.4), while between in situ and FDM it ranged from poor to satisfactory (<0.75). Generalized linear model showed that the differences did not reach statistically significant levels (p>0.05). According to Bland-Altman approach, the size of measurements did not bias the outcomes. The intraoral scanning and 3D printing techniques used in this study enabled the reproducibility of linear measurements, however, discrete distortions that might be clinically significant occurred.
publishDate 2021
dc.date.none.fl_str_mv 2021-09-03
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/13370
10.33448/rsd-v10i11.13370
url https://rsdjournal.org/index.php/rsd/article/view/13370
identifier_str_mv 10.33448/rsd-v10i11.13370
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/13370/17599
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 11; e344101113370
Research, Society and Development; Vol. 10 Núm. 11; e344101113370
Research, Society and Development; v. 10 n. 11; e344101113370
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052746498572288