Resumo: Layer-by-Layer (LbL) films containing silk fibroin (SF) and the 40 aminoacid-long amyloid-β peptide (Aβ1-40) were prepared with the purpose of developing a new prototype of an electrochemical immunosensor. The film showed a satisfactory growth in quartz substrate and screen-printed carbon electrodes, as observed by UV-vis spectroscopy and cyclic voltammetric, respectively. The peptide immobilized in LbL films in junction with SF shows secondary structure induced, as shown by circular dichroism measurements, favoring the interaction SF/peptide LbL film with the specific antibody. Immunosensor showed a linear response in the presence of the antibody with concentrations from 0 to 10 ng mL- 1 both analyzed by current changes in 0.3 V and voltammogram area. This system can be applied as a new prototype for preliminary diagnosis of Alzheimer's disease.
id UNSP_1fd17bf532d226c927f681740b894b5e
oai_identifier_str oai:repositorio.unesp.br:11449/168712
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin filmsAlzheimer's diseaseAmyloid-β peptideImmunosensorLayer-by-layerSilk fibroinLayer-by-Layer (LbL) films containing silk fibroin (SF) and the 40 aminoacid-long amyloid-β peptide (Aβ1-40) were prepared with the purpose of developing a new prototype of an electrochemical immunosensor. The film showed a satisfactory growth in quartz substrate and screen-printed carbon electrodes, as observed by UV-vis spectroscopy and cyclic voltammetric, respectively. The peptide immobilized in LbL films in junction with SF shows secondary structure induced, as shown by circular dichroism measurements, favoring the interaction SF/peptide LbL film with the specific antibody. Immunosensor showed a linear response in the presence of the antibody with concentrations from 0 to 10 ng mL- 1 both analyzed by current changes in 0.3 V and voltammogram area. This system can be applied as a new prototype for preliminary diagnosis of Alzheimer's disease.Instituto de Química Universidade Estadual Paulista Júlio de Mesquita Filho UNESP, Rua Professor Francisco Degni, 55Instituto de Ciência e Tecnologia Universidade Federal de São Paulo UNIFESP, Rua Talim, 330Instituto de Química Universidade Estadual Paulista Júlio de Mesquita Filho UNESP, Rua Professor Francisco Degni, 55Universidade Estadual Paulista (Unesp)Universidade Federal de São Paulo (UNIFESP)Gonçalves, J. M. [UNESP]Lima, L. R. [UNESP]Moraes, M. L.Ribeiro, S. J.L. [UNESP]2018-12-11T16:42:40Z2018-12-11T16:42:40Z2016-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article338-342application/pdfhttp://dx.doi.org/10.1016/j.msec.2016.05.101Materials Science and Engineering C, v. 68, p. 338-342.0928-4931http://hdl.handle.net/11449/16871210.1016/j.msec.2016.05.1012-s2.0-849732778312-s2.0-84973277831.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMaterials Science and Engineering C1,110info:eu-repo/semantics/openAccess2023-11-06T06:06:51Zoai:repositorio.unesp.br:11449/168712Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:00:13.218048Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
title Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
spellingShingle Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
Gonçalves, J. M. [UNESP]
Alzheimer's disease
Amyloid-β peptide
Immunosensor
Layer-by-layer
Silk fibroin
title_short Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
title_full Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
title_fullStr Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
title_full_unstemmed Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
title_sort Immunosensor for diagnosis of Alzheimer disease using amyloid-β 1-40 peptide and silk fibroin thin films
author Gonçalves, J. M. [UNESP]
author_facet Gonçalves, J. M. [UNESP]
Lima, L. R. [UNESP]
Moraes, M. L.
Ribeiro, S. J.L. [UNESP]
author_role author
author2 Lima, L. R. [UNESP]
Moraes, M. L.
Ribeiro, S. J.L. [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade Federal de São Paulo (UNIFESP)
dc.contributor.author.fl_str_mv Gonçalves, J. M. [UNESP]
Lima, L. R. [UNESP]
Moraes, M. L.
Ribeiro, S. J.L. [UNESP]
dc.subject.por.fl_str_mv Alzheimer's disease
Amyloid-β peptide
Immunosensor
Layer-by-layer
Silk fibroin
topic Alzheimer's disease
Amyloid-β peptide
Immunosensor
Layer-by-layer
Silk fibroin
description Layer-by-Layer (LbL) films containing silk fibroin (SF) and the 40 aminoacid-long amyloid-β peptide (Aβ1-40) were prepared with the purpose of developing a new prototype of an electrochemical immunosensor. The film showed a satisfactory growth in quartz substrate and screen-printed carbon electrodes, as observed by UV-vis spectroscopy and cyclic voltammetric, respectively. The peptide immobilized in LbL films in junction with SF shows secondary structure induced, as shown by circular dichroism measurements, favoring the interaction SF/peptide LbL film with the specific antibody. Immunosensor showed a linear response in the presence of the antibody with concentrations from 0 to 10 ng mL- 1 both analyzed by current changes in 0.3 V and voltammogram area. This system can be applied as a new prototype for preliminary diagnosis of Alzheimer's disease.
publishDate 2016
dc.date.none.fl_str_mv 2016-11-01
2018-12-11T16:42:40Z
2018-12-11T16:42:40Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.msec.2016.05.101
Materials Science and Engineering C, v. 68, p. 338-342.
0928-4931
http://hdl.handle.net/11449/168712
10.1016/j.msec.2016.05.101
2-s2.0-84973277831
2-s2.0-84973277831.pdf
url http://dx.doi.org/10.1016/j.msec.2016.05.101
http://hdl.handle.net/11449/168712
identifier_str_mv Materials Science and Engineering C, v. 68, p. 338-342.
0928-4931
10.1016/j.msec.2016.05.101
2-s2.0-84973277831
2-s2.0-84973277831.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Materials Science and Engineering C
1,110
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 338-342
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128735702941696