Radiopacity and flow of different endodontic sealers

Detalhes bibliográficos
Autor(a) principal: Tanomaru-Filho, Mario
Data de Publicação: 2013
Outros Autores: Bosso, Roberta, Viapiana, Raqueli, Guerreiro-Tanomaru, Juliane M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/231318
Resumo: The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10 mm in diameter and 1 mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 +/- 0.005 mll of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p > 0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p > 0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.
id UNSP_5674fae1b6a1bb89f9709555fb9a7eb2
oai_identifier_str oai:repositorio.unesp.br:11449/231318
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Radiopacity and flow of different endodontic sealersThe present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10 mm in diameter and 1 mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 +/- 0.005 mll of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p > 0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p > 0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ Estadual Paulista, Araraquara, SP, Brazil. tanomaru@uol.com.brUniversidade Estadual Paulista (UNESP)Tanomaru-Filho, MarioBosso, RobertaViapiana, RaqueliGuerreiro-Tanomaru, Juliane M.2022-04-29T08:44:47Z2022-04-29T08:44:47Z2013-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article121-125Acta odontológica latinoamericana : AOL, v. 26, n. 2, p. 121-125, 2013.0326-4815http://hdl.handle.net/11449/2313182-s2.0-84892868113Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengActa odontológica latinoamericana : AOLinfo:eu-repo/semantics/openAccess2024-09-27T18:04:18Zoai:repositorio.unesp.br:11449/231318Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T18:04:18Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Radiopacity and flow of different endodontic sealers
title Radiopacity and flow of different endodontic sealers
spellingShingle Radiopacity and flow of different endodontic sealers
Tanomaru-Filho, Mario
title_short Radiopacity and flow of different endodontic sealers
title_full Radiopacity and flow of different endodontic sealers
title_fullStr Radiopacity and flow of different endodontic sealers
title_full_unstemmed Radiopacity and flow of different endodontic sealers
title_sort Radiopacity and flow of different endodontic sealers
author Tanomaru-Filho, Mario
author_facet Tanomaru-Filho, Mario
Bosso, Roberta
Viapiana, Raqueli
Guerreiro-Tanomaru, Juliane M.
author_role author
author2 Bosso, Roberta
Viapiana, Raqueli
Guerreiro-Tanomaru, Juliane M.
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Tanomaru-Filho, Mario
Bosso, Roberta
Viapiana, Raqueli
Guerreiro-Tanomaru, Juliane M.
description The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10 mm in diameter and 1 mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 +/- 0.005 mll of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p > 0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p > 0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.
publishDate 2013
dc.date.none.fl_str_mv 2013-01-01
2022-04-29T08:44:47Z
2022-04-29T08:44:47Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv Acta odontológica latinoamericana : AOL, v. 26, n. 2, p. 121-125, 2013.
0326-4815
http://hdl.handle.net/11449/231318
2-s2.0-84892868113
identifier_str_mv Acta odontológica latinoamericana : AOL, v. 26, n. 2, p. 121-125, 2013.
0326-4815
2-s2.0-84892868113
url http://hdl.handle.net/11449/231318
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta odontológica latinoamericana : AOL
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 121-125
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1826304385620115456