Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite

Detalhes bibliográficos
Autor(a) principal: Ranzani, J. J. [UNESP]
Data de Publicação: 1997
Outros Autores: Rahal, Sheila Canevese [UNESP], Schellini, Silvana Artioli [UNESP], Marques, M. E. A. [UNESP], Taga, E. M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/S0100-879X1997001000007
http://hdl.handle.net/11449/12554
Resumo: We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity
id UNSP_67239968ac9de250b82353b00137e8a4
oai_identifier_str oai:repositorio.unesp.br:11449/12554
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Repair of the anophthalmic cavity of rats with synthetic hydroxyapatitesynthetic hydroxyapatitereconstruction of the anophthalmic cavityexperimental ratsWe placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavityUniversidade Estadual PaulistaA02Universidade de São PauloUniversidade Estadual PaulistaAssociação Brasileira de Divulgação Científica (ABRADIC)Universidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Ranzani, J. J. [UNESP]Rahal, Sheila Canevese [UNESP]Schellini, Silvana Artioli [UNESP]Marques, M. E. A. [UNESP]Taga, E. M.2014-05-20T13:36:28Z2014-05-20T13:36:28Z1997-10-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1181-1186application/pdfhttp://dx.doi.org/10.1590/S0100-879X1997001000007Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 30, n. 10, p. 1181-1186, 1997.0100-879Xhttp://hdl.handle.net/11449/1255410.1590/S0100-879X1997001000007S0100-879X1997001000007S0100-879X1997001000007.pdf149743326539019494202491008354920000-0002-9211-4093SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Journal of Medical and Biological Research1.492info:eu-repo/semantics/openAccess2024-08-16T18:44:17Zoai:repositorio.unesp.br:11449/12554Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-16T18:44:17Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
title Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
spellingShingle Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
Ranzani, J. J. [UNESP]
synthetic hydroxyapatite
reconstruction of the anophthalmic cavity
experimental rats
title_short Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
title_full Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
title_fullStr Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
title_full_unstemmed Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
title_sort Repair of the anophthalmic cavity of rats with synthetic hydroxyapatite
author Ranzani, J. J. [UNESP]
author_facet Ranzani, J. J. [UNESP]
Rahal, Sheila Canevese [UNESP]
Schellini, Silvana Artioli [UNESP]
Marques, M. E. A. [UNESP]
Taga, E. M.
author_role author
author2 Rahal, Sheila Canevese [UNESP]
Schellini, Silvana Artioli [UNESP]
Marques, M. E. A. [UNESP]
Taga, E. M.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Ranzani, J. J. [UNESP]
Rahal, Sheila Canevese [UNESP]
Schellini, Silvana Artioli [UNESP]
Marques, M. E. A. [UNESP]
Taga, E. M.
dc.subject.por.fl_str_mv synthetic hydroxyapatite
reconstruction of the anophthalmic cavity
experimental rats
topic synthetic hydroxyapatite
reconstruction of the anophthalmic cavity
experimental rats
description We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity
publishDate 1997
dc.date.none.fl_str_mv 1997-10-01
2014-05-20T13:36:28Z
2014-05-20T13:36:28Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0100-879X1997001000007
Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 30, n. 10, p. 1181-1186, 1997.
0100-879X
http://hdl.handle.net/11449/12554
10.1590/S0100-879X1997001000007
S0100-879X1997001000007
S0100-879X1997001000007.pdf
1497433265390194
9420249100835492
0000-0002-9211-4093
url http://dx.doi.org/10.1590/S0100-879X1997001000007
http://hdl.handle.net/11449/12554
identifier_str_mv Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 30, n. 10, p. 1181-1186, 1997.
0100-879X
10.1590/S0100-879X1997001000007
S0100-879X1997001000007
S0100-879X1997001000007.pdf
1497433265390194
9420249100835492
0000-0002-9211-4093
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Journal of Medical and Biological Research
1.492
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1181-1186
application/pdf
dc.publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica (ABRADIC)
publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica (ABRADIC)
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128175243264000