Experimental assessment of impedance-based structural health monitoring in radioactive environment

Detalhes bibliográficos
Autor(a) principal: de Souza Campos, Fernando [UNESP]
Data de Publicação: 2023
Outros Autores: Albuquerque de Castro, Bruno [UNESP], Tavares de Assis, Helder [UNESP], Zeituni, Carlos Alberto, Covolan Ulson, José Alfredo [UNESP], Baptista, Fabricio Guimarães [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1088/1361-6501/accebd
http://hdl.handle.net/11449/247280
Resumo: This work presents an experimental study of the influence of radiation on structural health monitoring systems based on the electromechanical impedance method using low-cost piezoelectric diaphragms. For application of the method, the baseline was obtained without radiation and then compared by damage indices after application of radiation. Considering applications in nuclear power plants, the irradiation and calculation of damage indices were performed in the range of 10 kGy-60 kGy at 10 kGy intervals. Impedance measurements were performed in seven frequency bands between 0 and 65 kHz. The results show that, due to the change in the impedance signatures, the damage indices values increase according to the total applied radiation dose, which may indicate a false indication of damage. Besides, results indicate that there are frequency bands less sensitive to radiation and a threshold can be defined to distinguish radiation from structural damage.
id UNSP_718be2045bb51bfc546f329c7841b990
oai_identifier_str oai:repositorio.unesp.br:11449/247280
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Experimental assessment of impedance-based structural health monitoring in radioactive environmentimpedancepiezoelectricityradiationSHMtransducerThis work presents an experimental study of the influence of radiation on structural health monitoring systems based on the electromechanical impedance method using low-cost piezoelectric diaphragms. For application of the method, the baseline was obtained without radiation and then compared by damage indices after application of radiation. Considering applications in nuclear power plants, the irradiation and calculation of damage indices were performed in the range of 10 kGy-60 kGy at 10 kGy intervals. Impedance measurements were performed in seven frequency bands between 0 and 65 kHz. The results show that, due to the change in the impedance signatures, the damage indices values increase according to the total applied radiation dose, which may indicate a false indication of damage. Besides, results indicate that there are frequency bands less sensitive to radiation and a threshold can be defined to distinguish radiation from structural damage.Department of Electrical Engineering Sao Paulo State University, Av. Eng. Edmundo Carrijo Coube 14-01 SPRadiation Technology Center—CETER Institute of Nuclear and Energy Center, Av. Prof. Lineu Prestes 2242 SPDepartment of Electrical Engineering Sao Paulo State University, Av. Eng. Edmundo Carrijo Coube 14-01 SPUniversidade Estadual Paulista (UNESP)Institute of Nuclear and Energy Centerde Souza Campos, Fernando [UNESP]Albuquerque de Castro, Bruno [UNESP]Tavares de Assis, Helder [UNESP]Zeituni, Carlos AlbertoCovolan Ulson, José Alfredo [UNESP]Baptista, Fabricio Guimarães [UNESP]2023-07-29T13:11:46Z2023-07-29T13:11:46Z2023-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1088/1361-6501/accebdMeasurement Science and Technology, v. 34, n. 8, 2023.1361-65010957-0233http://hdl.handle.net/11449/24728010.1088/1361-6501/accebd2-s2.0-85154548131Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMeasurement Science and Technologyinfo:eu-repo/semantics/openAccess2023-07-29T13:11:46Zoai:repositorio.unesp.br:11449/247280Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:22:29.565313Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Experimental assessment of impedance-based structural health monitoring in radioactive environment
title Experimental assessment of impedance-based structural health monitoring in radioactive environment
spellingShingle Experimental assessment of impedance-based structural health monitoring in radioactive environment
de Souza Campos, Fernando [UNESP]
impedance
piezoelectricity
radiation
SHM
transducer
title_short Experimental assessment of impedance-based structural health monitoring in radioactive environment
title_full Experimental assessment of impedance-based structural health monitoring in radioactive environment
title_fullStr Experimental assessment of impedance-based structural health monitoring in radioactive environment
title_full_unstemmed Experimental assessment of impedance-based structural health monitoring in radioactive environment
title_sort Experimental assessment of impedance-based structural health monitoring in radioactive environment
author de Souza Campos, Fernando [UNESP]
author_facet de Souza Campos, Fernando [UNESP]
Albuquerque de Castro, Bruno [UNESP]
Tavares de Assis, Helder [UNESP]
Zeituni, Carlos Alberto
Covolan Ulson, José Alfredo [UNESP]
Baptista, Fabricio Guimarães [UNESP]
author_role author
author2 Albuquerque de Castro, Bruno [UNESP]
Tavares de Assis, Helder [UNESP]
Zeituni, Carlos Alberto
Covolan Ulson, José Alfredo [UNESP]
Baptista, Fabricio Guimarães [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
Institute of Nuclear and Energy Center
dc.contributor.author.fl_str_mv de Souza Campos, Fernando [UNESP]
Albuquerque de Castro, Bruno [UNESP]
Tavares de Assis, Helder [UNESP]
Zeituni, Carlos Alberto
Covolan Ulson, José Alfredo [UNESP]
Baptista, Fabricio Guimarães [UNESP]
dc.subject.por.fl_str_mv impedance
piezoelectricity
radiation
SHM
transducer
topic impedance
piezoelectricity
radiation
SHM
transducer
description This work presents an experimental study of the influence of radiation on structural health monitoring systems based on the electromechanical impedance method using low-cost piezoelectric diaphragms. For application of the method, the baseline was obtained without radiation and then compared by damage indices after application of radiation. Considering applications in nuclear power plants, the irradiation and calculation of damage indices were performed in the range of 10 kGy-60 kGy at 10 kGy intervals. Impedance measurements were performed in seven frequency bands between 0 and 65 kHz. The results show that, due to the change in the impedance signatures, the damage indices values increase according to the total applied radiation dose, which may indicate a false indication of damage. Besides, results indicate that there are frequency bands less sensitive to radiation and a threshold can be defined to distinguish radiation from structural damage.
publishDate 2023
dc.date.none.fl_str_mv 2023-07-29T13:11:46Z
2023-07-29T13:11:46Z
2023-08-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1088/1361-6501/accebd
Measurement Science and Technology, v. 34, n. 8, 2023.
1361-6501
0957-0233
http://hdl.handle.net/11449/247280
10.1088/1361-6501/accebd
2-s2.0-85154548131
url http://dx.doi.org/10.1088/1361-6501/accebd
http://hdl.handle.net/11449/247280
identifier_str_mv Measurement Science and Technology, v. 34, n. 8, 2023.
1361-6501
0957-0233
10.1088/1361-6501/accebd
2-s2.0-85154548131
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Measurement Science and Technology
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128800047759360