Experimental assessment of impedance-based structural health monitoring in radioactive environment
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1088/1361-6501/accebd http://hdl.handle.net/11449/247280 |
Resumo: | This work presents an experimental study of the influence of radiation on structural health monitoring systems based on the electromechanical impedance method using low-cost piezoelectric diaphragms. For application of the method, the baseline was obtained without radiation and then compared by damage indices after application of radiation. Considering applications in nuclear power plants, the irradiation and calculation of damage indices were performed in the range of 10 kGy-60 kGy at 10 kGy intervals. Impedance measurements were performed in seven frequency bands between 0 and 65 kHz. The results show that, due to the change in the impedance signatures, the damage indices values increase according to the total applied radiation dose, which may indicate a false indication of damage. Besides, results indicate that there are frequency bands less sensitive to radiation and a threshold can be defined to distinguish radiation from structural damage. |
id |
UNSP_718be2045bb51bfc546f329c7841b990 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/247280 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Experimental assessment of impedance-based structural health monitoring in radioactive environmentimpedancepiezoelectricityradiationSHMtransducerThis work presents an experimental study of the influence of radiation on structural health monitoring systems based on the electromechanical impedance method using low-cost piezoelectric diaphragms. For application of the method, the baseline was obtained without radiation and then compared by damage indices after application of radiation. Considering applications in nuclear power plants, the irradiation and calculation of damage indices were performed in the range of 10 kGy-60 kGy at 10 kGy intervals. Impedance measurements were performed in seven frequency bands between 0 and 65 kHz. The results show that, due to the change in the impedance signatures, the damage indices values increase according to the total applied radiation dose, which may indicate a false indication of damage. Besides, results indicate that there are frequency bands less sensitive to radiation and a threshold can be defined to distinguish radiation from structural damage.Department of Electrical Engineering Sao Paulo State University, Av. Eng. Edmundo Carrijo Coube 14-01 SPRadiation Technology Center—CETER Institute of Nuclear and Energy Center, Av. Prof. Lineu Prestes 2242 SPDepartment of Electrical Engineering Sao Paulo State University, Av. Eng. Edmundo Carrijo Coube 14-01 SPUniversidade Estadual Paulista (UNESP)Institute of Nuclear and Energy Centerde Souza Campos, Fernando [UNESP]Albuquerque de Castro, Bruno [UNESP]Tavares de Assis, Helder [UNESP]Zeituni, Carlos AlbertoCovolan Ulson, José Alfredo [UNESP]Baptista, Fabricio Guimarães [UNESP]2023-07-29T13:11:46Z2023-07-29T13:11:46Z2023-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1088/1361-6501/accebdMeasurement Science and Technology, v. 34, n. 8, 2023.1361-65010957-0233http://hdl.handle.net/11449/24728010.1088/1361-6501/accebd2-s2.0-85154548131Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMeasurement Science and Technologyinfo:eu-repo/semantics/openAccess2023-07-29T13:11:46Zoai:repositorio.unesp.br:11449/247280Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:22:29.565313Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Experimental assessment of impedance-based structural health monitoring in radioactive environment |
title |
Experimental assessment of impedance-based structural health monitoring in radioactive environment |
spellingShingle |
Experimental assessment of impedance-based structural health monitoring in radioactive environment de Souza Campos, Fernando [UNESP] impedance piezoelectricity radiation SHM transducer |
title_short |
Experimental assessment of impedance-based structural health monitoring in radioactive environment |
title_full |
Experimental assessment of impedance-based structural health monitoring in radioactive environment |
title_fullStr |
Experimental assessment of impedance-based structural health monitoring in radioactive environment |
title_full_unstemmed |
Experimental assessment of impedance-based structural health monitoring in radioactive environment |
title_sort |
Experimental assessment of impedance-based structural health monitoring in radioactive environment |
author |
de Souza Campos, Fernando [UNESP] |
author_facet |
de Souza Campos, Fernando [UNESP] Albuquerque de Castro, Bruno [UNESP] Tavares de Assis, Helder [UNESP] Zeituni, Carlos Alberto Covolan Ulson, José Alfredo [UNESP] Baptista, Fabricio Guimarães [UNESP] |
author_role |
author |
author2 |
Albuquerque de Castro, Bruno [UNESP] Tavares de Assis, Helder [UNESP] Zeituni, Carlos Alberto Covolan Ulson, José Alfredo [UNESP] Baptista, Fabricio Guimarães [UNESP] |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) Institute of Nuclear and Energy Center |
dc.contributor.author.fl_str_mv |
de Souza Campos, Fernando [UNESP] Albuquerque de Castro, Bruno [UNESP] Tavares de Assis, Helder [UNESP] Zeituni, Carlos Alberto Covolan Ulson, José Alfredo [UNESP] Baptista, Fabricio Guimarães [UNESP] |
dc.subject.por.fl_str_mv |
impedance piezoelectricity radiation SHM transducer |
topic |
impedance piezoelectricity radiation SHM transducer |
description |
This work presents an experimental study of the influence of radiation on structural health monitoring systems based on the electromechanical impedance method using low-cost piezoelectric diaphragms. For application of the method, the baseline was obtained without radiation and then compared by damage indices after application of radiation. Considering applications in nuclear power plants, the irradiation and calculation of damage indices were performed in the range of 10 kGy-60 kGy at 10 kGy intervals. Impedance measurements were performed in seven frequency bands between 0 and 65 kHz. The results show that, due to the change in the impedance signatures, the damage indices values increase according to the total applied radiation dose, which may indicate a false indication of damage. Besides, results indicate that there are frequency bands less sensitive to radiation and a threshold can be defined to distinguish radiation from structural damage. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-07-29T13:11:46Z 2023-07-29T13:11:46Z 2023-08-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1088/1361-6501/accebd Measurement Science and Technology, v. 34, n. 8, 2023. 1361-6501 0957-0233 http://hdl.handle.net/11449/247280 10.1088/1361-6501/accebd 2-s2.0-85154548131 |
url |
http://dx.doi.org/10.1088/1361-6501/accebd http://hdl.handle.net/11449/247280 |
identifier_str_mv |
Measurement Science and Technology, v. 34, n. 8, 2023. 1361-6501 0957-0233 10.1088/1361-6501/accebd 2-s2.0-85154548131 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Measurement Science and Technology |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128800047759360 |