Resumo: Wollastonite bioceramics prepared from synthetic and natural precursors were implanted in rats in bone and subcutaneous tissues. The implant sites were excised after 7, 30 and 120 days, fixed, dehydrated, embedded in paraffin wax for serial cutting and examined under transmitted light microscope. It was found a very similar behavior for both wollastonite bioceramics. They were biocompatible, bioactive and biodegradable when implanted in rat bone. The synthetic ceramic was more reabsorbable than the one from natural powder. When implanted in subcutaneous rat tissue, both materials elicited a mild initial inflammatory reaction that practically disappeared after 120 days. Both materials were encapsulated with a very thin fibrous capsule and slightly reabsorbed at their surfaces. None of the materials induced ectopic osteogenesis. According to the results, the studied materials seem to be able for manufacturing reabsorbable bone implants.
id UNSP_c62f69565db07575080c399619b9bf1b
oai_identifier_str oai:repositorio.unesp.br:11449/70289
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursorsBiocompatibilityCalcium phosphateIn vivo testWollastoniteBioactivityBoneRatsBioceramicsWollastonite bioceramics prepared from synthetic and natural precursors were implanted in rats in bone and subcutaneous tissues. The implant sites were excised after 7, 30 and 120 days, fixed, dehydrated, embedded in paraffin wax for serial cutting and examined under transmitted light microscope. It was found a very similar behavior for both wollastonite bioceramics. They were biocompatible, bioactive and biodegradable when implanted in rat bone. The synthetic ceramic was more reabsorbable than the one from natural powder. When implanted in subcutaneous rat tissue, both materials elicited a mild initial inflammatory reaction that practically disappeared after 120 days. Both materials were encapsulated with a very thin fibrous capsule and slightly reabsorbed at their surfaces. None of the materials induced ectopic osteogenesis. According to the results, the studied materials seem to be able for manufacturing reabsorbable bone implants.Depto. de Morfologia Fac. de Odontologia de Araraquara UNESP, Rua Humaitá, 1680, 14.801-903 Araraquara-SPCentro de Biomateriales Universidad de La Habana, Ave. Universidad s/n e/ G y Ronda, 10400 La HabanaDpto. de Cerámica Instituto de Cerámica y Vidrio CSIC, C/ Kelsen, 5, Cantoblanco, 28049 MadridInstituto de Bioingeniería Universidad Miguel Hernández Edificio Vilanopó, Avda. Universidad s/n, 03202 Elche, AlicanteDepto. de Morfologia Fac. de Odontologia de Araraquara UNESP, Rua Humaitá, 1680, 14.801-903 Araraquara-SPUniversidade Estadual Paulista (Unesp)Universidad de La HabanaCSICEdificio VilanopóMinarelli-Gaspar, A. M. [UNESP]Saska, S. [UNESP]Da Cunha, L. R. [UNESP]Bolini, Paulo Domingos André [UNESP]Carrodeguas, R. G.De Aza, A. H.Pena, P.De Aza, P. N.De Aza, S.2014-05-27T11:22:48Z2014-05-27T11:22:48Z2008-01-22info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject1083-1086http://dx.doi.org/10.4028/www.scientific.net/KEM.361-363.1083Key Engineering Materials, v. 361-363 II, p. 1083-1086.1013-9826http://hdl.handle.net/11449/7028910.4028/www.scientific.net/KEM.361-363.1083WOS:0002534802002672-s2.0-381490689881393640448238401Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengKey Engineering Materials0,180info:eu-repo/semantics/openAccess2024-09-27T15:15:20Zoai:repositorio.unesp.br:11449/70289Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T15:15:20Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
title Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
spellingShingle Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
Minarelli-Gaspar, A. M. [UNESP]
Biocompatibility
Calcium phosphate
In vivo test
Wollastonite
Bioactivity
Bone
Rats
Bioceramics
title_short Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
title_full Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
title_fullStr Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
title_full_unstemmed Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
title_sort Comparison of the biological behavior of wollastonite bioceramics prepared from synthetic and natural precursors
author Minarelli-Gaspar, A. M. [UNESP]
author_facet Minarelli-Gaspar, A. M. [UNESP]
Saska, S. [UNESP]
Da Cunha, L. R. [UNESP]
Bolini, Paulo Domingos André [UNESP]
Carrodeguas, R. G.
De Aza, A. H.
Pena, P.
De Aza, P. N.
De Aza, S.
author_role author
author2 Saska, S. [UNESP]
Da Cunha, L. R. [UNESP]
Bolini, Paulo Domingos André [UNESP]
Carrodeguas, R. G.
De Aza, A. H.
Pena, P.
De Aza, P. N.
De Aza, S.
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidad de La Habana
CSIC
Edificio Vilanopó
dc.contributor.author.fl_str_mv Minarelli-Gaspar, A. M. [UNESP]
Saska, S. [UNESP]
Da Cunha, L. R. [UNESP]
Bolini, Paulo Domingos André [UNESP]
Carrodeguas, R. G.
De Aza, A. H.
Pena, P.
De Aza, P. N.
De Aza, S.
dc.subject.por.fl_str_mv Biocompatibility
Calcium phosphate
In vivo test
Wollastonite
Bioactivity
Bone
Rats
Bioceramics
topic Biocompatibility
Calcium phosphate
In vivo test
Wollastonite
Bioactivity
Bone
Rats
Bioceramics
description Wollastonite bioceramics prepared from synthetic and natural precursors were implanted in rats in bone and subcutaneous tissues. The implant sites were excised after 7, 30 and 120 days, fixed, dehydrated, embedded in paraffin wax for serial cutting and examined under transmitted light microscope. It was found a very similar behavior for both wollastonite bioceramics. They were biocompatible, bioactive and biodegradable when implanted in rat bone. The synthetic ceramic was more reabsorbable than the one from natural powder. When implanted in subcutaneous rat tissue, both materials elicited a mild initial inflammatory reaction that practically disappeared after 120 days. Both materials were encapsulated with a very thin fibrous capsule and slightly reabsorbed at their surfaces. None of the materials induced ectopic osteogenesis. According to the results, the studied materials seem to be able for manufacturing reabsorbable bone implants.
publishDate 2008
dc.date.none.fl_str_mv 2008-01-22
2014-05-27T11:22:48Z
2014-05-27T11:22:48Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.4028/www.scientific.net/KEM.361-363.1083
Key Engineering Materials, v. 361-363 II, p. 1083-1086.
1013-9826
http://hdl.handle.net/11449/70289
10.4028/www.scientific.net/KEM.361-363.1083
WOS:000253480200267
2-s2.0-38149068988
1393640448238401
url http://dx.doi.org/10.4028/www.scientific.net/KEM.361-363.1083
http://hdl.handle.net/11449/70289
identifier_str_mv Key Engineering Materials, v. 361-363 II, p. 1083-1086.
1013-9826
10.4028/www.scientific.net/KEM.361-363.1083
WOS:000253480200267
2-s2.0-38149068988
1393640448238401
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Key Engineering Materials
0,180
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1083-1086
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546451733577728