Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor

Detalhes bibliográficos
Autor(a) principal: Fernandes, João Roberto [UNESP]
Data de Publicação: 1996
Outros Autores: De Oliveira Neto, Graciliano, Tubino, Matthieu, Kubota, Lauro T.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.2116/analsci.12.443
http://hdl.handle.net/11449/64933
Resumo: A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.
id UNSP_ca2298cab87d8fa0dfde4689cf3cde2f
oai_identifier_str oai:repositorio.unesp.br:11449/64933
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme ReactorGrassOxalate determinationOxalate oxidaseSorghum vulgare seedsA new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.Inst. de Química da Unicamp, POBox 6154, 13083-970, Campinas, SPDepto. de Quimica Faculdade de Ciências Unesp, POBox 473, 17033-360, Bauru, SPDepto. de Quimica Faculdade de Ciências Unesp, POBox 473, 17033-360, Bauru, SPUniversidade Estadual de Campinas (UNICAMP)Universidade Estadual Paulista (Unesp)Fernandes, João Roberto [UNESP]De Oliveira Neto, GracilianoTubino, MatthieuKubota, Lauro T.2014-05-27T11:18:09Z2014-05-27T11:18:09Z1996-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article443-447application/pdfhttp://dx.doi.org/10.2116/analsci.12.443Analytical Sciences, v. 12, n. 3, p. 443-447, 1996.0910-6340http://hdl.handle.net/11449/6493310.2116/analsci.12.4432-s2.0-00305100012-s2.0-0030510001.pdf8540599256820672Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengAnalytical Sciences1.3550,424info:eu-repo/semantics/openAccess2024-04-29T18:17:12Zoai:repositorio.unesp.br:11449/64933Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T21:37:08.719867Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
title Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
spellingShingle Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
Fernandes, João Roberto [UNESP]
Grass
Oxalate determination
Oxalate oxidase
Sorghum vulgare seeds
title_short Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
title_full Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
title_fullStr Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
title_full_unstemmed Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
title_sort Determination of Oxalate in Grass by FIA with a Spectrophotometric Detection System Using a Two Enzyme Reactor
author Fernandes, João Roberto [UNESP]
author_facet Fernandes, João Roberto [UNESP]
De Oliveira Neto, Graciliano
Tubino, Matthieu
Kubota, Lauro T.
author_role author
author2 De Oliveira Neto, Graciliano
Tubino, Matthieu
Kubota, Lauro T.
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual de Campinas (UNICAMP)
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Fernandes, João Roberto [UNESP]
De Oliveira Neto, Graciliano
Tubino, Matthieu
Kubota, Lauro T.
dc.subject.por.fl_str_mv Grass
Oxalate determination
Oxalate oxidase
Sorghum vulgare seeds
topic Grass
Oxalate determination
Oxalate oxidase
Sorghum vulgare seeds
description A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.
publishDate 1996
dc.date.none.fl_str_mv 1996-12-01
2014-05-27T11:18:09Z
2014-05-27T11:18:09Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.2116/analsci.12.443
Analytical Sciences, v. 12, n. 3, p. 443-447, 1996.
0910-6340
http://hdl.handle.net/11449/64933
10.2116/analsci.12.443
2-s2.0-0030510001
2-s2.0-0030510001.pdf
8540599256820672
url http://dx.doi.org/10.2116/analsci.12.443
http://hdl.handle.net/11449/64933
identifier_str_mv Analytical Sciences, v. 12, n. 3, p. 443-447, 1996.
0910-6340
10.2116/analsci.12.443
2-s2.0-0030510001
2-s2.0-0030510001.pdf
8540599256820672
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Analytical Sciences
1.355
0,424
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 443-447
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129341757849600