Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos

Detalhes bibliográficos
Autor(a) principal: Mansur, Sérgio Said [UNESP]
Data de Publicação: 1998
Outros Autores: Mercier, Pierre
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://revistas.abcm.org.br/indexed/vol_xx_-_n_01_-_mar_1998.pdf
http://hdl.handle.net/11449/65411
Resumo: Classical shell-and-tube heat exchangers are usually equipped with segmental baffles. These baffles serve two basic functions: (a) they provide tube supports, thereby preventing or reducing mechanical problems, such as sagging or vibration; (b) they direct the fluid flow over the tubes so as to introduce a cross-flow component, thereby increasing the heat transfer. Segmented baffles have several sources of performance loss, some due to various leakage flows and others caused by stagnation zones. A new concept of longitudinal flow heat exchanger - based on placing twisted tapes along the tube bundle subchannels - was developed to mitigate drawbacks of other types of tubular heat exchangers. In this paper, a numerical model has been implemented in order to simulate the thermal-hydraulic feature of tubular heat exchangers equipped either with segmental baffles or with subchannel twisted tapes. The tube bundle has been described by means of an equivalent porous medium type model, allowing a macroscopic description of the shell-side flow. The basic equations - continuity, momentum and energy - have been solved by using the finite volume method. Typical numerical results have been compared with experimental data, reaching a very good agreement. A comparative analysis of different types of heat exchangers has been carried out, revealing the satisfactory thermal-hydraulic efficiency level of the twisted tapes heat exchangers.
id UNSP_da3862d39ff430b92bda6dbec4b231d2
oai_identifier_str oai:repositorio.unesp.br:11449/65411
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubosNumerical simulation of multitubular heat exchangers equipped with twisted tapes outside the tubesFinite Volume MethodFlow VisualizationHeat ExchangerShell and TubesTwisted TapesComputational fluid dynamicsComputer simulationEquations of motionFinite volume methodFlow visualizationMathematical modelsNumerical analysisPipe flowMultitubular heat exchangersSegmental bafflesSubchannel twisted tapesHeat exchangersClassical shell-and-tube heat exchangers are usually equipped with segmental baffles. These baffles serve two basic functions: (a) they provide tube supports, thereby preventing or reducing mechanical problems, such as sagging or vibration; (b) they direct the fluid flow over the tubes so as to introduce a cross-flow component, thereby increasing the heat transfer. Segmented baffles have several sources of performance loss, some due to various leakage flows and others caused by stagnation zones. A new concept of longitudinal flow heat exchanger - based on placing twisted tapes along the tube bundle subchannels - was developed to mitigate drawbacks of other types of tubular heat exchangers. In this paper, a numerical model has been implemented in order to simulate the thermal-hydraulic feature of tubular heat exchangers equipped either with segmental baffles or with subchannel twisted tapes. The tube bundle has been described by means of an equivalent porous medium type model, allowing a macroscopic description of the shell-side flow. The basic equations - continuity, momentum and energy - have been solved by using the finite volume method. Typical numerical results have been compared with experimental data, reaching a very good agreement. A comparative analysis of different types of heat exchangers has been carried out, revealing the satisfactory thermal-hydraulic efficiency level of the twisted tapes heat exchangers.Universidade Estadual Paulista Faculdade Engenharia Ilha Solteira Depto. de Engenharia Mecânica, 15385-000 Ilha SolteiraCommsrt. à l'Energie Atomique Ctr. D Etud. Nucleaires de Grenoble Groupement pour Rech. sur les E., 38000 GrenobleUniversidade Estadual Paulista Faculdade Engenharia Ilha Solteira Depto. de Engenharia Mecânica, 15385-000 Ilha SolteiraUniversidade Estadual Paulista (Unesp)Groupement pour Rech. sur les E.Mansur, Sérgio Said [UNESP]Mercier, Pierre2014-05-27T11:19:33Z2014-05-27T11:19:33Z1998-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article79-90application/pdfhttp://revistas.abcm.org.br/indexed/vol_xx_-_n_01_-_mar_1998.pdfRevista Brasileira de Ciencias Mecanicas/Journal of the Brazilian Society of Mechanical Sciences, v. 20, n. 1, p. 79-90, 1998.0100-7386http://hdl.handle.net/11449/654112-s2.0-00320253202-s2.0-0032025320.pdf1345872386974896Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporRevista Brasileira de Ciencias Mecanicas/Journal of the Brazilian Society of Mechanical Sciencesinfo:eu-repo/semantics/openAccess2024-07-04T20:06:03Zoai:repositorio.unesp.br:11449/65411Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:52:06.496975Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
Numerical simulation of multitubular heat exchangers equipped with twisted tapes outside the tubes
title Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
spellingShingle Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
Mansur, Sérgio Said [UNESP]
Finite Volume Method
Flow Visualization
Heat Exchanger
Shell and Tubes
Twisted Tapes
Computational fluid dynamics
Computer simulation
Equations of motion
Finite volume method
Flow visualization
Mathematical models
Numerical analysis
Pipe flow
Multitubular heat exchangers
Segmental baffles
Subchannel twisted tapes
Heat exchangers
title_short Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
title_full Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
title_fullStr Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
title_full_unstemmed Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
title_sort Simulação numérica de trocadores de calor multitubulares equipados com fitas helicoidais externamente aos tubos
author Mansur, Sérgio Said [UNESP]
author_facet Mansur, Sérgio Said [UNESP]
Mercier, Pierre
author_role author
author2 Mercier, Pierre
author2_role author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Groupement pour Rech. sur les E.
dc.contributor.author.fl_str_mv Mansur, Sérgio Said [UNESP]
Mercier, Pierre
dc.subject.por.fl_str_mv Finite Volume Method
Flow Visualization
Heat Exchanger
Shell and Tubes
Twisted Tapes
Computational fluid dynamics
Computer simulation
Equations of motion
Finite volume method
Flow visualization
Mathematical models
Numerical analysis
Pipe flow
Multitubular heat exchangers
Segmental baffles
Subchannel twisted tapes
Heat exchangers
topic Finite Volume Method
Flow Visualization
Heat Exchanger
Shell and Tubes
Twisted Tapes
Computational fluid dynamics
Computer simulation
Equations of motion
Finite volume method
Flow visualization
Mathematical models
Numerical analysis
Pipe flow
Multitubular heat exchangers
Segmental baffles
Subchannel twisted tapes
Heat exchangers
description Classical shell-and-tube heat exchangers are usually equipped with segmental baffles. These baffles serve two basic functions: (a) they provide tube supports, thereby preventing or reducing mechanical problems, such as sagging or vibration; (b) they direct the fluid flow over the tubes so as to introduce a cross-flow component, thereby increasing the heat transfer. Segmented baffles have several sources of performance loss, some due to various leakage flows and others caused by stagnation zones. A new concept of longitudinal flow heat exchanger - based on placing twisted tapes along the tube bundle subchannels - was developed to mitigate drawbacks of other types of tubular heat exchangers. In this paper, a numerical model has been implemented in order to simulate the thermal-hydraulic feature of tubular heat exchangers equipped either with segmental baffles or with subchannel twisted tapes. The tube bundle has been described by means of an equivalent porous medium type model, allowing a macroscopic description of the shell-side flow. The basic equations - continuity, momentum and energy - have been solved by using the finite volume method. Typical numerical results have been compared with experimental data, reaching a very good agreement. A comparative analysis of different types of heat exchangers has been carried out, revealing the satisfactory thermal-hydraulic efficiency level of the twisted tapes heat exchangers.
publishDate 1998
dc.date.none.fl_str_mv 1998-03-01
2014-05-27T11:19:33Z
2014-05-27T11:19:33Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://revistas.abcm.org.br/indexed/vol_xx_-_n_01_-_mar_1998.pdf
Revista Brasileira de Ciencias Mecanicas/Journal of the Brazilian Society of Mechanical Sciences, v. 20, n. 1, p. 79-90, 1998.
0100-7386
http://hdl.handle.net/11449/65411
2-s2.0-0032025320
2-s2.0-0032025320.pdf
1345872386974896
url http://revistas.abcm.org.br/indexed/vol_xx_-_n_01_-_mar_1998.pdf
http://hdl.handle.net/11449/65411
identifier_str_mv Revista Brasileira de Ciencias Mecanicas/Journal of the Brazilian Society of Mechanical Sciences, v. 20, n. 1, p. 79-90, 1998.
0100-7386
2-s2.0-0032025320
2-s2.0-0032025320.pdf
1345872386974896
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv Revista Brasileira de Ciencias Mecanicas/Journal of the Brazilian Society of Mechanical Sciences
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 79-90
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128575927222272