The effect of splint material rigidity in implant impression techniques

Detalhes bibliográficos
Autor(a) principal: Del’Acqua, Marcelo Antonialli
Data de Publicação: 2010
Outros Autores: Chávez, Alejandro Muñoz [UNESP], Castanharo, Sabrina Maria [UNESP], Compagnoni, Marco Antonio [UNESP], de Assis Mollo, Francisco [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://hdl.handle.net/11449/226257
Resumo: Purpose: This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Two groups (D and M) were tested (n = 5). The measurement method employed was just one titanium screw tightened to the framework. Each group’s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at × 100 magnification. The results were analyzed statistically (t test). Results: The mean values of abutment/framework interface gaps were: master cast = 32 µm (SD 2), group D =165 µm (SD 60), and group M = 69 µm (SD 36). There was a statistically significant difference between the D and M groups (P = .001). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings. © 2010 by Quintessence Publishing Co Inc.
id UNSP_fdb5db322cd65a2c96f314e761620c86
oai_identifier_str oai:repositorio.unesp.br:11449/226257
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling The effect of splint material rigidity in implant impression techniquesDental implantImplant impression techniqueSplinting materialPurpose: This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Two groups (D and M) were tested (n = 5). The measurement method employed was just one titanium screw tightened to the framework. Each group’s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at × 100 magnification. The results were analyzed statistically (t test). Results: The mean values of abutment/framework interface gaps were: master cast = 32 µm (SD 2), group D =165 µm (SD 60), and group M = 69 µm (SD 36). There was a statistically significant difference between the D and M groups (P = .001). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings. © 2010 by Quintessence Publishing Co Inc.Araraquara University Center-UNIARA, Araraquara, São PauloDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São PauloDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São PauloAraraquara University Center-UNIARAUniversidade Estadual Paulista (UNESP)Del’Acqua, Marcelo AntonialliChávez, Alejandro Muñoz [UNESP]Castanharo, Sabrina Maria [UNESP]Compagnoni, Marco Antonio [UNESP]de Assis Mollo, Francisco [UNESP]2022-04-28T22:13:40Z2022-04-28T22:13:40Z2010-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1153-1158International Journal of Oral and Maxillofacial Implants, v. 25, n. 6, p. 1153-1158, 2010.0882-2786http://hdl.handle.net/11449/2262572-s2.0-79952296180Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal of Oral and Maxillofacial Implantsinfo:eu-repo/semantics/openAccess2022-04-28T22:13:40Zoai:repositorio.unesp.br:11449/226257Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-04-28T22:13:40Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv The effect of splint material rigidity in implant impression techniques
title The effect of splint material rigidity in implant impression techniques
spellingShingle The effect of splint material rigidity in implant impression techniques
Del’Acqua, Marcelo Antonialli
Dental implant
Implant impression technique
Splinting material
title_short The effect of splint material rigidity in implant impression techniques
title_full The effect of splint material rigidity in implant impression techniques
title_fullStr The effect of splint material rigidity in implant impression techniques
title_full_unstemmed The effect of splint material rigidity in implant impression techniques
title_sort The effect of splint material rigidity in implant impression techniques
author Del’Acqua, Marcelo Antonialli
author_facet Del’Acqua, Marcelo Antonialli
Chávez, Alejandro Muñoz [UNESP]
Castanharo, Sabrina Maria [UNESP]
Compagnoni, Marco Antonio [UNESP]
de Assis Mollo, Francisco [UNESP]
author_role author
author2 Chávez, Alejandro Muñoz [UNESP]
Castanharo, Sabrina Maria [UNESP]
Compagnoni, Marco Antonio [UNESP]
de Assis Mollo, Francisco [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Araraquara University Center-UNIARA
Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Del’Acqua, Marcelo Antonialli
Chávez, Alejandro Muñoz [UNESP]
Castanharo, Sabrina Maria [UNESP]
Compagnoni, Marco Antonio [UNESP]
de Assis Mollo, Francisco [UNESP]
dc.subject.por.fl_str_mv Dental implant
Implant impression technique
Splinting material
topic Dental implant
Implant impression technique
Splinting material
description Purpose: This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Two groups (D and M) were tested (n = 5). The measurement method employed was just one titanium screw tightened to the framework. Each group’s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at × 100 magnification. The results were analyzed statistically (t test). Results: The mean values of abutment/framework interface gaps were: master cast = 32 µm (SD 2), group D =165 µm (SD 60), and group M = 69 µm (SD 36). There was a statistically significant difference between the D and M groups (P = .001). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings. © 2010 by Quintessence Publishing Co Inc.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
2022-04-28T22:13:40Z
2022-04-28T22:13:40Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv International Journal of Oral and Maxillofacial Implants, v. 25, n. 6, p. 1153-1158, 2010.
0882-2786
http://hdl.handle.net/11449/226257
2-s2.0-79952296180
identifier_str_mv International Journal of Oral and Maxillofacial Implants, v. 25, n. 6, p. 1153-1158, 2010.
0882-2786
2-s2.0-79952296180
url http://hdl.handle.net/11449/226257
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv International Journal of Oral and Maxillofacial Implants
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1153-1158
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799965634999615488