Accuracy comparison of implant impression techniques: A systematic review

Detalhes bibliográficos
Autor(a) principal: Moreira, António Herculano Jesus
Data de Publicação: 2015
Outros Autores: Rodrigues, Nuno F., Pinho, A. C. Marques de, Fonseca, Jaime C., Vilaça, João L.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/40227
Resumo: Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
id RCAP_b3d05302086bce57a815d2954c636dc2
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/40227
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Accuracy comparison of implant impression techniques: A systematic reviewImplant impressionImplant misfitImpression accuracyOptical scanningDental prosthesisCiências Médicas::Medicina ClínicaScience & TechnologyBackground Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.FCT – Fundação para a Ciência e Tecnologia in the scope of the Ph.D. grant SFRH/BD/68270/2010, project EXPL/BBB-BMD/2146/2013 and within the Project Scope UID/CEC/00319/2013WileyUniversidade do MinhoMoreira, António Herculano JesusRodrigues, Nuno F.Pinho, A. C. Marques deFonseca, Jaime C.Vilaça, João L.2015-102015-10-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/40227engMoreira, A. H., Rodrigues, N. F., Pinho, A., Fonseca, J. C., & Vilaça, J. L. (2015). Accuracy Comparison of Implant Impression Techniques: A Systematic Review. Clinical implant dentistry and related research, 17(S2), e751-e7641523-089910.1111/cid.1231025828851http://onlinelibrary.wiley.com/doi/10.1111/cid.12310/fullinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T11:54:35Zoai:repositorium.sdum.uminho.pt:1822/40227Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:44:04.268278Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Accuracy comparison of implant impression techniques: A systematic review
title Accuracy comparison of implant impression techniques: A systematic review
spellingShingle Accuracy comparison of implant impression techniques: A systematic review
Moreira, António Herculano Jesus
Implant impression
Implant misfit
Impression accuracy
Optical scanning
Dental prosthesis
Ciências Médicas::Medicina Clínica
Science & Technology
title_short Accuracy comparison of implant impression techniques: A systematic review
title_full Accuracy comparison of implant impression techniques: A systematic review
title_fullStr Accuracy comparison of implant impression techniques: A systematic review
title_full_unstemmed Accuracy comparison of implant impression techniques: A systematic review
title_sort Accuracy comparison of implant impression techniques: A systematic review
author Moreira, António Herculano Jesus
author_facet Moreira, António Herculano Jesus
Rodrigues, Nuno F.
Pinho, A. C. Marques de
Fonseca, Jaime C.
Vilaça, João L.
author_role author
author2 Rodrigues, Nuno F.
Pinho, A. C. Marques de
Fonseca, Jaime C.
Vilaça, João L.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Moreira, António Herculano Jesus
Rodrigues, Nuno F.
Pinho, A. C. Marques de
Fonseca, Jaime C.
Vilaça, João L.
dc.subject.por.fl_str_mv Implant impression
Implant misfit
Impression accuracy
Optical scanning
Dental prosthesis
Ciências Médicas::Medicina Clínica
Science & Technology
topic Implant impression
Implant misfit
Impression accuracy
Optical scanning
Dental prosthesis
Ciências Médicas::Medicina Clínica
Science & Technology
description Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
publishDate 2015
dc.date.none.fl_str_mv 2015-10
2015-10-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/40227
url http://hdl.handle.net/1822/40227
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Moreira, A. H., Rodrigues, N. F., Pinho, A., Fonseca, J. C., & Vilaça, J. L. (2015). Accuracy Comparison of Implant Impression Techniques: A Systematic Review. Clinical implant dentistry and related research, 17(S2), e751-e764
1523-0899
10.1111/cid.12310
25828851
http://onlinelibrary.wiley.com/doi/10.1111/cid.12310/full
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Wiley
publisher.none.fl_str_mv Wiley
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132189486481408