A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/47983 |
Resumo: | OBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P |
id |
USP-17_639b3249b6d91184f9254b0ceadadad7 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/47983 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutmentPlaster castsImplant-supported dental prosthesisDental impression materialsOBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (PUniversidade de São Paulo. Faculdade de Odontologia de Bauru2012-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/4798310.1590/S1678-77572012000500004Journal of Applied Oral Science; Vol. 20 No. 5 (2012); 517-521Journal of Applied Oral Science; Vol. 20 Núm. 5 (2012); 517-521Journal of Applied Oral Science; v. 20 n. 5 (2012); 517-5211678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/47983/51723Copyright (c) 2012 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessAndrade, Pâmela Cândida Aires Ribas deLuthi, Leonardo FloresStanley, KyleCardoso, Antônio Carlos2012-12-13T12:10:16Zoai:revistas.usp.br:article/47983Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-12-13T12:10:16Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment |
title |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment |
spellingShingle |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment Andrade, Pâmela Cândida Aires Ribas de Plaster casts Implant-supported dental prosthesis Dental impression materials |
title_short |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment |
title_full |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment |
title_fullStr |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment |
title_full_unstemmed |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment |
title_sort |
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment |
author |
Andrade, Pâmela Cândida Aires Ribas de |
author_facet |
Andrade, Pâmela Cândida Aires Ribas de Luthi, Leonardo Flores Stanley, Kyle Cardoso, Antônio Carlos |
author_role |
author |
author2 |
Luthi, Leonardo Flores Stanley, Kyle Cardoso, Antônio Carlos |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Andrade, Pâmela Cândida Aires Ribas de Luthi, Leonardo Flores Stanley, Kyle Cardoso, Antônio Carlos |
dc.subject.por.fl_str_mv |
Plaster casts Implant-supported dental prosthesis Dental impression materials |
topic |
Plaster casts Implant-supported dental prosthesis Dental impression materials |
description |
OBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/47983 10.1590/S1678-77572012000500004 |
url |
https://www.revistas.usp.br/jaos/article/view/47983 |
identifier_str_mv |
10.1590/S1678-77572012000500004 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/47983/51723 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2012 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2012 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 20 No. 5 (2012); 517-521 Journal of Applied Oral Science; Vol. 20 Núm. 5 (2012); 517-521 Journal of Applied Oral Science; v. 20 n. 5 (2012); 517-521 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221677480574976 |