A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment

Detalhes bibliográficos
Autor(a) principal: Andrade, Pâmela Cândida Aires Ribas de
Data de Publicação: 2012
Outros Autores: Luthi, Leonardo Flores, Stanley, Kyle, Cardoso, Antônio Carlos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/47983
Resumo: OBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P
id USP-17_639b3249b6d91184f9254b0ceadadad7
oai_identifier_str oai:revistas.usp.br:article/47983
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutmentPlaster castsImplant-supported dental prosthesisDental impression materialsOBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (PUniversidade de São Paulo. Faculdade de Odontologia de Bauru2012-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/4798310.1590/S1678-77572012000500004Journal of Applied Oral Science; Vol. 20 No. 5 (2012); 517-521Journal of Applied Oral Science; Vol. 20 Núm. 5 (2012); 517-521Journal of Applied Oral Science; v. 20 n. 5 (2012); 517-5211678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/47983/51723Copyright (c) 2012 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessAndrade, Pâmela Cândida Aires Ribas deLuthi, Leonardo FloresStanley, KyleCardoso, Antônio Carlos2012-12-13T12:10:16Zoai:revistas.usp.br:article/47983Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-12-13T12:10:16Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
title A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
spellingShingle A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
Andrade, Pâmela Cândida Aires Ribas de
Plaster casts
Implant-supported dental prosthesis
Dental impression materials
title_short A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
title_full A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
title_fullStr A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
title_full_unstemmed A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
title_sort A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
author Andrade, Pâmela Cândida Aires Ribas de
author_facet Andrade, Pâmela Cândida Aires Ribas de
Luthi, Leonardo Flores
Stanley, Kyle
Cardoso, Antônio Carlos
author_role author
author2 Luthi, Leonardo Flores
Stanley, Kyle
Cardoso, Antônio Carlos
author2_role author
author
author
dc.contributor.author.fl_str_mv Andrade, Pâmela Cândida Aires Ribas de
Luthi, Leonardo Flores
Stanley, Kyle
Cardoso, Antônio Carlos
dc.subject.por.fl_str_mv Plaster casts
Implant-supported dental prosthesis
Dental impression materials
topic Plaster casts
Implant-supported dental prosthesis
Dental impression materials
description OBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P
publishDate 2012
dc.date.none.fl_str_mv 2012-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/47983
10.1590/S1678-77572012000500004
url https://www.revistas.usp.br/jaos/article/view/47983
identifier_str_mv 10.1590/S1678-77572012000500004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/47983/51723
dc.rights.driver.fl_str_mv Copyright (c) 2012 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2012 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 20 No. 5 (2012); 517-521
Journal of Applied Oral Science; Vol. 20 Núm. 5 (2012); 517-521
Journal of Applied Oral Science; v. 20 n. 5 (2012); 517-521
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221677480574976