High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide

Detalhes bibliográficos
Autor(a) principal: NAM, Seoul Hee
Data de Publicação: 2013
Outros Autores: LEE, Hyun Woo, CHO, Soo Hyun, LEE, Jae Koo, JEON, Young Chan, KIM, Gyoo Cheon
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/80467
Resumo: Light-activated tooth bleaching with a high hydrogen peroxide (HP; H2O2) concentration has risks and the actual role of the light source is doubtful. The use of conventional light might result in an increase in the temperature and cause thermal damage to the health of the tooth tissue. Objective This study investigated the efficacy of tooth bleaching using non-thermal atmospheric pressure plasma (NAPP) with 15% carbamide peroxide (CP; CH6N2O3) including 5.4% HP, as compared with conventional light sources. Material and Methods Forty human teeth were randomly divided into four groups: Group I (CP+NAPP), Group II (CP+plasma arc lamp; PAC), Group III (CP+diode laser), and Group IV (CP alone). Color changes (∆E) of the tooth and tooth surface temperatures were measured. Data were evaluated by one-way analysis of variance (ANOVA) and post-hoc Tukey's tests. Results Group I showed the highest bleaching efficacy, with a ∆E value of 1.92-, 2.61 and 2.97-fold greater than those of Groups II, III and IV, respectively (P
id USP-17_bc0ab8205f93708402668650461a56c1
oai_identifier_str oai:revistas.usp.br:article/80467
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide Light-activated tooth bleaching with a high hydrogen peroxide (HP; H2O2) concentration has risks and the actual role of the light source is doubtful. The use of conventional light might result in an increase in the temperature and cause thermal damage to the health of the tooth tissue. Objective This study investigated the efficacy of tooth bleaching using non-thermal atmospheric pressure plasma (NAPP) with 15% carbamide peroxide (CP; CH6N2O3) including 5.4% HP, as compared with conventional light sources. Material and Methods Forty human teeth were randomly divided into four groups: Group I (CP+NAPP), Group II (CP+plasma arc lamp; PAC), Group III (CP+diode laser), and Group IV (CP alone). Color changes (∆E) of the tooth and tooth surface temperatures were measured. Data were evaluated by one-way analysis of variance (ANOVA) and post-hoc Tukey's tests. Results Group I showed the highest bleaching efficacy, with a ∆E value of 1.92-, 2.61 and 2.97-fold greater than those of Groups II, III and IV, respectively (PUniversidade de São Paulo. Faculdade de Odontologia de Bauru2013-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/8046710.1590/1679-775720130016Journal of Applied Oral Science; Vol. 21 No. 3 (2013); 265-270Journal of Applied Oral Science; Vol. 21 Núm. 3 (2013); 265-270Journal of Applied Oral Science; v. 21 n. 3 (2013); 265-2701678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/80467/84130Copyright (c) 2013 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessNAM, Seoul Hee LEE, Hyun Woo CHO, Soo Hyun LEE, Jae Koo JEON, Young Chan KIM, Gyoo Cheon 2014-05-08T13:22:42Zoai:revistas.usp.br:article/80467Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2014-05-08T13:22:42Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
title High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
spellingShingle High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
NAM, Seoul Hee
title_short High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
title_full High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
title_fullStr High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
title_full_unstemmed High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
title_sort High-efficiency tooth bleaching using non-thermal atmospheric pressure plasma with low concentration of hydrogen peroxide
author NAM, Seoul Hee
author_facet NAM, Seoul Hee
LEE, Hyun Woo
CHO, Soo Hyun
LEE, Jae Koo
JEON, Young Chan
KIM, Gyoo Cheon
author_role author
author2 LEE, Hyun Woo
CHO, Soo Hyun
LEE, Jae Koo
JEON, Young Chan
KIM, Gyoo Cheon
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv NAM, Seoul Hee
LEE, Hyun Woo
CHO, Soo Hyun
LEE, Jae Koo
JEON, Young Chan
KIM, Gyoo Cheon
description Light-activated tooth bleaching with a high hydrogen peroxide (HP; H2O2) concentration has risks and the actual role of the light source is doubtful. The use of conventional light might result in an increase in the temperature and cause thermal damage to the health of the tooth tissue. Objective This study investigated the efficacy of tooth bleaching using non-thermal atmospheric pressure plasma (NAPP) with 15% carbamide peroxide (CP; CH6N2O3) including 5.4% HP, as compared with conventional light sources. Material and Methods Forty human teeth were randomly divided into four groups: Group I (CP+NAPP), Group II (CP+plasma arc lamp; PAC), Group III (CP+diode laser), and Group IV (CP alone). Color changes (∆E) of the tooth and tooth surface temperatures were measured. Data were evaluated by one-way analysis of variance (ANOVA) and post-hoc Tukey's tests. Results Group I showed the highest bleaching efficacy, with a ∆E value of 1.92-, 2.61 and 2.97-fold greater than those of Groups II, III and IV, respectively (P
publishDate 2013
dc.date.none.fl_str_mv 2013-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/80467
10.1590/1679-775720130016
url https://www.revistas.usp.br/jaos/article/view/80467
identifier_str_mv 10.1590/1679-775720130016
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/80467/84130
dc.rights.driver.fl_str_mv Copyright (c) 2013 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2013 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 21 No. 3 (2013); 265-270
Journal of Applied Oral Science; Vol. 21 Núm. 3 (2013); 265-270
Journal of Applied Oral Science; v. 21 n. 3 (2013); 265-270
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221677579141120