Resumo: An ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.
id FIOCRUZ-4_5b5cf363b800a4d2ea0f4aa9ff320171
oai_identifier_str oai:scielo:S0074-02761990000300012
network_acronym_str FIOCRUZ-4
network_name_str Memórias do Instituto Oswaldo Cruz
spelling Serological diagnosis of dengue by an Elisa inhibition method (EIM)ELISA Inhibition MethodMAC-ELISAdengueAn ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.Instituto Oswaldo Cruz, Ministério da Saúde1990-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02761990000300012Memórias do Instituto Oswaldo Cruz v.85 n.3 1990reponame:Memórias do Instituto Oswaldo Cruzinstname:Fundação Oswaldo Cruzinstacron:FIOCRUZ10.1590/S0074-02761990000300012info:eu-repo/semantics/openAccessFernandez,R. J.Vazquez,S.eng2020-04-25T17:46:30Zhttp://www.scielo.br/oai/scielo-oai.php0074-02761678-8060opendoar:null2020-04-26 02:03:48.565Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruztrue
dc.title.none.fl_str_mv Serological diagnosis of dengue by an Elisa inhibition method (EIM)
title Serological diagnosis of dengue by an Elisa inhibition method (EIM)
spellingShingle Serological diagnosis of dengue by an Elisa inhibition method (EIM)
Fernandez,R. J.
ELISA Inhibition Method
MAC-ELISA
dengue
title_short Serological diagnosis of dengue by an Elisa inhibition method (EIM)
title_full Serological diagnosis of dengue by an Elisa inhibition method (EIM)
title_fullStr Serological diagnosis of dengue by an Elisa inhibition method (EIM)
title_full_unstemmed Serological diagnosis of dengue by an Elisa inhibition method (EIM)
title_sort Serological diagnosis of dengue by an Elisa inhibition method (EIM)
author Fernandez,R. J.
author_facet Fernandez,R. J.
Vazquez,S.
author_role author
author2 Vazquez,S.
author2_role author
dc.contributor.author.fl_str_mv Fernandez,R. J.
Vazquez,S.
dc.subject.por.fl_str_mv ELISA Inhibition Method
MAC-ELISA
dengue
topic ELISA Inhibition Method
MAC-ELISA
dengue
dc.description.none.fl_txt_mv An ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.
description An ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.
publishDate 1990
dc.date.none.fl_str_mv 1990-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02761990000300012
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02761990000300012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0074-02761990000300012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Oswaldo Cruz, Ministério da Saúde
publisher.none.fl_str_mv Instituto Oswaldo Cruz, Ministério da Saúde
dc.source.none.fl_str_mv Memórias do Instituto Oswaldo Cruz v.85 n.3 1990
reponame:Memórias do Instituto Oswaldo Cruz
instname:Fundação Oswaldo Cruz
instacron:FIOCRUZ
reponame_str Memórias do Instituto Oswaldo Cruz
collection Memórias do Instituto Oswaldo Cruz
instname_str Fundação Oswaldo Cruz
instacron_str FIOCRUZ
institution FIOCRUZ
repository.name.fl_str_mv Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruz
repository.mail.fl_str_mv
_version_ 1669937655595401216