Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots

Detalhes bibliográficos
Autor(a) principal: Ribas,Graziela Schmitt
Data de Publicação: 2017
Outros Autores: Mari,Jurema Fátima De, Civallero,Gabriel, Souza,Heryk Motta de, Burin,Maira Graeff, Vargas,Carmen Regla, Giugliani,Roberto
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of Inborn Errors of Metabolism and Screening
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2326-45942017000100302
Resumo: Abstract Background: Interest in screening methods for lysosomal storage diseases (LSDs) has increased in recent years, since early diagnosis and treatment are essential to prevent or attenuate the onset of symptoms and the complications of these diseases. In the current work, we evaluated the performance of tandem mass spectrometry (MS/MS) for the detection of some LSDs, aiming the future use of this methodology for the screening of these disorders. Methods: Standard curves and quality control dried blood spots were assayed to evaluate the precision, linearity, and accuracy. A total of 150 controls were grouped according to age and subjected to measurement of lysosomal enzymes deficient in Niemann-Pick A/B, Krabbe, Gaucher, Fabry, Pompe, and Mucopolysaccharidosis type I diseases. Samples from 59 affected patients with a diagnosis of LSDs previously confirmed by fluorimetric methods were analyzed. Results: Data from standard calibration demonstrated good linearity and accuracy and the intra- and interassay precisions varied from 1.17% to 11.60% and 5.39% to 31.24%, respectively. Except for galactocerebrosidase and ?-l-iduronidase, enzyme activities were significantly higher in newborns compared to children and adult controls. Affected patients presented enzymatic activities significantly lower compared to all control participants. Conclusion: Our results show that MS/MS is a promising methodology, suitable for the screening of LSDs, but accurate diagnoses will depend on its correlation with other biochemical and/or molecular analyses.
id IGPT-1_365f6a29d13beda20ad94ef813cb3152
oai_identifier_str oai:scielo:S2326-45942017000100302
network_acronym_str IGPT-1
network_name_str Journal of Inborn Errors of Metabolism and Screening
repository_id_str
spelling Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spotslysosomal storage diseasesmultiplex enzyme assaytandem mass spectrometryAbstract Background: Interest in screening methods for lysosomal storage diseases (LSDs) has increased in recent years, since early diagnosis and treatment are essential to prevent or attenuate the onset of symptoms and the complications of these diseases. In the current work, we evaluated the performance of tandem mass spectrometry (MS/MS) for the detection of some LSDs, aiming the future use of this methodology for the screening of these disorders. Methods: Standard curves and quality control dried blood spots were assayed to evaluate the precision, linearity, and accuracy. A total of 150 controls were grouped according to age and subjected to measurement of lysosomal enzymes deficient in Niemann-Pick A/B, Krabbe, Gaucher, Fabry, Pompe, and Mucopolysaccharidosis type I diseases. Samples from 59 affected patients with a diagnosis of LSDs previously confirmed by fluorimetric methods were analyzed. Results: Data from standard calibration demonstrated good linearity and accuracy and the intra- and interassay precisions varied from 1.17% to 11.60% and 5.39% to 31.24%, respectively. Except for galactocerebrosidase and ?-l-iduronidase, enzyme activities were significantly higher in newborns compared to children and adult controls. Affected patients presented enzymatic activities significantly lower compared to all control participants. Conclusion: Our results show that MS/MS is a promising methodology, suitable for the screening of LSDs, but accurate diagnoses will depend on its correlation with other biochemical and/or molecular analyses.Latin American Society Inborn Errors and Neonatal Screening (SLEIMPN); Instituto Genética para Todos (IGPT)2017-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2326-45942017000100302Journal of Inborn Errors of Metabolism and Screening v.5 2017reponame:Journal of Inborn Errors of Metabolism and Screeninginstname:Instituto Genética para Todos (IGPT)instacron:IGPT10.1177/2326409817692360info:eu-repo/semantics/openAccessRibas,Graziela SchmittMari,Jurema Fátima DeCivallero,GabrielSouza,Heryk Motta deBurin,Maira GraeffVargas,Carmen ReglaGiugliani,Robertoeng2019-05-14T00:00:00Zoai:scielo:S2326-45942017000100302Revistahttp://jiems-journal.org/ONGhttps://old.scielo.br/oai/scielo-oai.phpjiems@jiems-journal.org||rgiugliani@hcpa.edu.br2326-45942326-4594opendoar:2019-05-14T00:00Journal of Inborn Errors of Metabolism and Screening - Instituto Genética para Todos (IGPT)false
dc.title.none.fl_str_mv Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
title Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
spellingShingle Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
Ribas,Graziela Schmitt
lysosomal storage diseases
multiplex enzyme assay
tandem mass spectrometry
title_short Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
title_full Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
title_fullStr Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
title_full_unstemmed Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
title_sort Validation of a Multiplex Tandem Mass Spectrometry Method for the Detection of Selected Lysosomal Storage Diseases in Dried Blood Spots
author Ribas,Graziela Schmitt
author_facet Ribas,Graziela Schmitt
Mari,Jurema Fátima De
Civallero,Gabriel
Souza,Heryk Motta de
Burin,Maira Graeff
Vargas,Carmen Regla
Giugliani,Roberto
author_role author
author2 Mari,Jurema Fátima De
Civallero,Gabriel
Souza,Heryk Motta de
Burin,Maira Graeff
Vargas,Carmen Regla
Giugliani,Roberto
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Ribas,Graziela Schmitt
Mari,Jurema Fátima De
Civallero,Gabriel
Souza,Heryk Motta de
Burin,Maira Graeff
Vargas,Carmen Regla
Giugliani,Roberto
dc.subject.por.fl_str_mv lysosomal storage diseases
multiplex enzyme assay
tandem mass spectrometry
topic lysosomal storage diseases
multiplex enzyme assay
tandem mass spectrometry
description Abstract Background: Interest in screening methods for lysosomal storage diseases (LSDs) has increased in recent years, since early diagnosis and treatment are essential to prevent or attenuate the onset of symptoms and the complications of these diseases. In the current work, we evaluated the performance of tandem mass spectrometry (MS/MS) for the detection of some LSDs, aiming the future use of this methodology for the screening of these disorders. Methods: Standard curves and quality control dried blood spots were assayed to evaluate the precision, linearity, and accuracy. A total of 150 controls were grouped according to age and subjected to measurement of lysosomal enzymes deficient in Niemann-Pick A/B, Krabbe, Gaucher, Fabry, Pompe, and Mucopolysaccharidosis type I diseases. Samples from 59 affected patients with a diagnosis of LSDs previously confirmed by fluorimetric methods were analyzed. Results: Data from standard calibration demonstrated good linearity and accuracy and the intra- and interassay precisions varied from 1.17% to 11.60% and 5.39% to 31.24%, respectively. Except for galactocerebrosidase and ?-l-iduronidase, enzyme activities were significantly higher in newborns compared to children and adult controls. Affected patients presented enzymatic activities significantly lower compared to all control participants. Conclusion: Our results show that MS/MS is a promising methodology, suitable for the screening of LSDs, but accurate diagnoses will depend on its correlation with other biochemical and/or molecular analyses.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2326-45942017000100302
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2326-45942017000100302
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1177/2326409817692360
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Latin American Society Inborn Errors and Neonatal Screening (SLEIMPN); Instituto Genética para Todos (IGPT)
publisher.none.fl_str_mv Latin American Society Inborn Errors and Neonatal Screening (SLEIMPN); Instituto Genética para Todos (IGPT)
dc.source.none.fl_str_mv Journal of Inborn Errors of Metabolism and Screening v.5 2017
reponame:Journal of Inborn Errors of Metabolism and Screening
instname:Instituto Genética para Todos (IGPT)
instacron:IGPT
instname_str Instituto Genética para Todos (IGPT)
instacron_str IGPT
institution IGPT
reponame_str Journal of Inborn Errors of Metabolism and Screening
collection Journal of Inborn Errors of Metabolism and Screening
repository.name.fl_str_mv Journal of Inborn Errors of Metabolism and Screening - Instituto Genética para Todos (IGPT)
repository.mail.fl_str_mv jiems@jiems-journal.org||rgiugliani@hcpa.edu.br
_version_ 1754732519966638080