Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models

Detalhes bibliográficos
Autor(a) principal: Moura, Carmem Dolores Vilarinho Soares de
Data de Publicação: 2010
Outros Autores: Moura, Walter Leal de, França, Fabiana Mantovani Gomes, Martins, Gregório Antônio Soares, Nogueira, Lorenna Bastos Lima Verde, Zanetti, Raquel Vírginia
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6252
Resumo: Purpose: To evaluate the surface roughness and dimensional stability of types III and IV gypsum models, obtained from irreversible hydrocolloid impressions after disinfection with 5.25% sodium hypochlorite steam. Methods: The impressions to obtain type III and type IV gypsum models were divided into 3 groups: Group 1 (disinfection with 5.25% sodium hypochlorite steam for 10 minutes); Group 2 (simulated disinfection with distilled water steam) and Group 3 (no treatment). To measure the dimensional changes with a digital caliper, 36 models (18 for each type of gypsum) were cast according to a stainless steel master model with four pillars. For the surface roughness measurement, 36 gypsum models were cast from the impressions of the polished stainless steel platform. The data were analyzed using ANOVA and Tukey’s test (α=1%). Results: There was no statistically significant difference in linear dimensions or surface roughness when the different disinfection treatments were compared (Groups 1, 2 and 3), for all types of gypsum. Conclusion: The disinfection treatments with sodium hypochlorite steam and distilled water steam for irreversible hydrocolloid impressions did not significantly affect the dimensional stability and surface roughness of the types III and IV gypsum dental models.
id PUC_RS-22_45f55a04a88f69df4f4b95e419dc5970
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/6252
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum modelsDesinfecção de moldes de hidrocolóide irreversível com vapor de hipoclorito de sódio: Avaliação dimensional e rugosidade superficial dos modelos de gessoBiosafetysodium hypochloritegypsumBiosafetydisinfectionBiossegurançahipoclorito de sódiogessoBiossegurançadesinfecçãoPurpose: To evaluate the surface roughness and dimensional stability of types III and IV gypsum models, obtained from irreversible hydrocolloid impressions after disinfection with 5.25% sodium hypochlorite steam. Methods: The impressions to obtain type III and type IV gypsum models were divided into 3 groups: Group 1 (disinfection with 5.25% sodium hypochlorite steam for 10 minutes); Group 2 (simulated disinfection with distilled water steam) and Group 3 (no treatment). To measure the dimensional changes with a digital caliper, 36 models (18 for each type of gypsum) were cast according to a stainless steel master model with four pillars. For the surface roughness measurement, 36 gypsum models were cast from the impressions of the polished stainless steel platform. The data were analyzed using ANOVA and Tukey’s test (α=1%). Results: There was no statistically significant difference in linear dimensions or surface roughness when the different disinfection treatments were compared (Groups 1, 2 and 3), for all types of gypsum. Conclusion: The disinfection treatments with sodium hypochlorite steam and distilled water steam for irreversible hydrocolloid impressions did not significantly affect the dimensional stability and surface roughness of the types III and IV gypsum dental models.Objetivo: Avaliar o comportamento dimensional e rugosidade superficial de modelos de gesso tipos III e IV, obtidos em moldes de hidrocolóide irreversível desinfetados com vapor de hipoclorito de sódio 5,25%. Metodologia: Os moldes para obtenção dos modelos de gesso tipo III e tipo IV foram designados: Grupo 1 (desinfecção com vapor de hipoclorito de sódio 5,25% por 10 minutos); Grupo 2 (simulação de desinfecção com vapor de água destilada) e Grupo 3 (sem tratamento). Para medição das alterações dimensionais, moldou-se modelo mestre de aço inox com quatro pilares e confeccionou-se 36 modelos (18 para cada tipo de gesso) e as distâncias foram mensuradas com paquímetro digital. Para leitura da rugosidade, confeccionaram-se 36 modelos a partir de moldes de plataforma de aço inox polida e avaliou-se a superfície dos gessos com rugosímetro. Os dados foram submetidos à análise de variância e teste de Tukey (α=1%). Resultados: Na medição das dimensões lineares entre pilares e leitura da rugosidade superficial, não houve diferença estatística significativa, quando comparados os tipos de tratamento (Grupos 1, 2 e 3) em nenhum dos tipos de gesso. Conclusão: Os tratamentos dos moldes de hidrocolóide irreversível com vapor de hipoclorito de sódio e água destilada não afetaram significantemente a estabilidade dimensional e a rugosidade superficial dos modelos de gesso tipo III e tipo IV.EDIPUCRS - Editora Universitária da PUCRS2010-06-22info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlein vitro; experimentallaboratorial; experimental; in vitroapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6252Revista Odonto Ciência; Vol. 25 No. 3 (2010); 276 - 281Revista Odonto Ciência; v. 25 n. 3 (2010); 276 - 2811980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6252/5548Moura, Carmem Dolores Vilarinho Soares deMoura, Walter Leal deFrança, Fabiana Mantovani GomesMartins, Gregório Antônio SoaresNogueira, Lorenna Bastos Lima VerdeZanetti, Raquel Vírginiainfo:eu-repo/semantics/openAccess2013-11-11T12:30:19Zoai:ojs.revistaseletronicas.pucrs.br:article/6252Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T12:30:19Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
Desinfecção de moldes de hidrocolóide irreversível com vapor de hipoclorito de sódio: Avaliação dimensional e rugosidade superficial dos modelos de gesso
title Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
spellingShingle Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
Moura, Carmem Dolores Vilarinho Soares de
Biosafety
sodium hypochlorite
gypsum
Biosafety
disinfection
Biossegurança
hipoclorito de sódio
gesso
Biossegurança
desinfecção
title_short Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
title_full Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
title_fullStr Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
title_full_unstemmed Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
title_sort Disinfection of irreversible hydrocolloid impressions with sodium hypochlorite steam: Assessment of surface roughness and dimensions of gypsum models
author Moura, Carmem Dolores Vilarinho Soares de
author_facet Moura, Carmem Dolores Vilarinho Soares de
Moura, Walter Leal de
França, Fabiana Mantovani Gomes
Martins, Gregório Antônio Soares
Nogueira, Lorenna Bastos Lima Verde
Zanetti, Raquel Vírginia
author_role author
author2 Moura, Walter Leal de
França, Fabiana Mantovani Gomes
Martins, Gregório Antônio Soares
Nogueira, Lorenna Bastos Lima Verde
Zanetti, Raquel Vírginia
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Moura, Carmem Dolores Vilarinho Soares de
Moura, Walter Leal de
França, Fabiana Mantovani Gomes
Martins, Gregório Antônio Soares
Nogueira, Lorenna Bastos Lima Verde
Zanetti, Raquel Vírginia
dc.subject.por.fl_str_mv Biosafety
sodium hypochlorite
gypsum
Biosafety
disinfection
Biossegurança
hipoclorito de sódio
gesso
Biossegurança
desinfecção
topic Biosafety
sodium hypochlorite
gypsum
Biosafety
disinfection
Biossegurança
hipoclorito de sódio
gesso
Biossegurança
desinfecção
description Purpose: To evaluate the surface roughness and dimensional stability of types III and IV gypsum models, obtained from irreversible hydrocolloid impressions after disinfection with 5.25% sodium hypochlorite steam. Methods: The impressions to obtain type III and type IV gypsum models were divided into 3 groups: Group 1 (disinfection with 5.25% sodium hypochlorite steam for 10 minutes); Group 2 (simulated disinfection with distilled water steam) and Group 3 (no treatment). To measure the dimensional changes with a digital caliper, 36 models (18 for each type of gypsum) were cast according to a stainless steel master model with four pillars. For the surface roughness measurement, 36 gypsum models were cast from the impressions of the polished stainless steel platform. The data were analyzed using ANOVA and Tukey’s test (α=1%). Results: There was no statistically significant difference in linear dimensions or surface roughness when the different disinfection treatments were compared (Groups 1, 2 and 3), for all types of gypsum. Conclusion: The disinfection treatments with sodium hypochlorite steam and distilled water steam for irreversible hydrocolloid impressions did not significantly affect the dimensional stability and surface roughness of the types III and IV gypsum dental models.
publishDate 2010
dc.date.none.fl_str_mv 2010-06-22
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
in vitro; experimental
laboratorial; experimental; in vitro
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6252
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6252
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/6252/5548
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 25 No. 3 (2010); 276 - 281
Revista Odonto Ciência; v. 25 n. 3 (2010); 276 - 281
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820875312431104