Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates

Detalhes bibliográficos
Autor(a) principal: Morais, Stephanie L.
Data de Publicação: 2021
Outros Autores: Barros, Piedade, Santos, Marlene, Delerue-Matos, Cristina, Gomes, Andreia C., Barroso, M. Fátima
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.22/18944
Resumo: This work addresses the development of a disposable electrochemical genosensor for the detection of the toxic dinoflagellate, Alexandrium minutum. Analyzing public databases, a specific 70 bp DNA probe, targeting A. minutum, was selected and designed. The genosensor methodology implied the immobilization of a A. minutum-specific DNA-capture probe onto screen-printed gold electrodes (SPGE). To improve both the selectivity and to avoid strong secondary structures, that could hinder the hybridization efficiency, a sandwich format of the A. minutum gene was designed using a fluorescein isothiocyanate-labelled signaling DNA probe and enzymatic amplification of the electrochemical signal. Using this electrochemical genosensor, a oncentration range from 0.12 to 1.0 nM, a LD of 24.78 pM with a RSD <5.2% was determined. The genosensor was successfully applied to the selective analysis of the targeted A. minutum specific region denatured genomic DNA extracted from toxic dinoflagellates present in the Atlantic Ocean.
id RCAP_b4d4fa15399c5c22a6c4cb907ef6d7e0
oai_identifier_str oai:recipp.ipp.pt:10400.22/18944
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellatesAlexandrium minutumDinoflagellateChronoamperometryElectrochemical genosensorSandwich format hybridizationThis work addresses the development of a disposable electrochemical genosensor for the detection of the toxic dinoflagellate, Alexandrium minutum. Analyzing public databases, a specific 70 bp DNA probe, targeting A. minutum, was selected and designed. The genosensor methodology implied the immobilization of a A. minutum-specific DNA-capture probe onto screen-printed gold electrodes (SPGE). To improve both the selectivity and to avoid strong secondary structures, that could hinder the hybridization efficiency, a sandwich format of the A. minutum gene was designed using a fluorescein isothiocyanate-labelled signaling DNA probe and enzymatic amplification of the electrochemical signal. Using this electrochemical genosensor, a oncentration range from 0.12 to 1.0 nM, a LD of 24.78 pM with a RSD <5.2% was determined. The genosensor was successfully applied to the selective analysis of the targeted A. minutum specific region denatured genomic DNA extracted from toxic dinoflagellates present in the Atlantic Ocean.ElsevierRepositório Científico do Instituto Politécnico do PortoMorais, Stephanie L.Barros, PiedadeSantos, MarleneDelerue-Matos, CristinaGomes, Andreia C.Barroso, M. Fátima2021-11-24T16:39:44Z2021-01-152021-01-15T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/18944engMorais, S. L., Barros, P., Santos, M., Delerue-Matos, C., Gomes, A. C., & Fátima Barroso, M. (2021). Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates. Talanta, 222, 121416. https://doi.org/10.1016/j.talanta.2020.1214160039-914010.1016/j.talanta.2020.121416metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T13:12:13Zoai:recipp.ipp.pt:10400.22/18944Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:38:59.665946Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
title Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
spellingShingle Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
Morais, Stephanie L.
Alexandrium minutum
Dinoflagellate
Chronoamperometry
Electrochemical genosensor
Sandwich format hybridization
title_short Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
title_full Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
title_fullStr Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
title_full_unstemmed Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
title_sort Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates
author Morais, Stephanie L.
author_facet Morais, Stephanie L.
Barros, Piedade
Santos, Marlene
Delerue-Matos, Cristina
Gomes, Andreia C.
Barroso, M. Fátima
author_role author
author2 Barros, Piedade
Santos, Marlene
Delerue-Matos, Cristina
Gomes, Andreia C.
Barroso, M. Fátima
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico do Porto
dc.contributor.author.fl_str_mv Morais, Stephanie L.
Barros, Piedade
Santos, Marlene
Delerue-Matos, Cristina
Gomes, Andreia C.
Barroso, M. Fátima
dc.subject.por.fl_str_mv Alexandrium minutum
Dinoflagellate
Chronoamperometry
Electrochemical genosensor
Sandwich format hybridization
topic Alexandrium minutum
Dinoflagellate
Chronoamperometry
Electrochemical genosensor
Sandwich format hybridization
description This work addresses the development of a disposable electrochemical genosensor for the detection of the toxic dinoflagellate, Alexandrium minutum. Analyzing public databases, a specific 70 bp DNA probe, targeting A. minutum, was selected and designed. The genosensor methodology implied the immobilization of a A. minutum-specific DNA-capture probe onto screen-printed gold electrodes (SPGE). To improve both the selectivity and to avoid strong secondary structures, that could hinder the hybridization efficiency, a sandwich format of the A. minutum gene was designed using a fluorescein isothiocyanate-labelled signaling DNA probe and enzymatic amplification of the electrochemical signal. Using this electrochemical genosensor, a oncentration range from 0.12 to 1.0 nM, a LD of 24.78 pM with a RSD <5.2% was determined. The genosensor was successfully applied to the selective analysis of the targeted A. minutum specific region denatured genomic DNA extracted from toxic dinoflagellates present in the Atlantic Ocean.
publishDate 2021
dc.date.none.fl_str_mv 2021-11-24T16:39:44Z
2021-01-15
2021-01-15T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/18944
url http://hdl.handle.net/10400.22/18944
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Morais, S. L., Barros, P., Santos, M., Delerue-Matos, C., Gomes, A. C., & Fátima Barroso, M. (2021). Electrochemical genosensor for the detection of Alexandrium minutum dinoflagellates. Talanta, 222, 121416. https://doi.org/10.1016/j.talanta.2020.121416
0039-9140
10.1016/j.talanta.2020.121416
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131477978382336