Resumo: Abstract Aortic dissection(AD) is a life-threatening disease due to a tear in the intimal layer of the aorta within the aortic wall. To compare diagnostic value and imaging of AD between computed tomography(CT) and magnetic resonance imaging (MRI). 120 AD patients diagnosed were examined with 64-slice CT and 1.5 MRI, the imaging data of true and false lumen, intimal flap, intimal tear, mural thrombus and aortic calcification were compared. The intimal flap rate of CT and MRI was 81.7% and 100%, respectively; The intimal tear rate of CT and MRI was 68.3% and 83.3%, respectively; The rate of mural thrombus in CT and MRI was 26.7% and 54.2%, respectively; The rate of aortic calcification in CT and MRI was 62.5% and 18.3%, respectively; The number of patients with intimal tear lower than 1mm in CT and MRI was 5 and 0, respectively. Both CT and MRI can show the true and false lumen well, but the detection rate of intimal flap, intimal tear and mural thrombosis in MRI is significantly higher than that in CT, and the detection rate of aortic calcification and intimal tear<1mm in CT is higher than that in MRI.
id SBCTA-1_d3c74b63923c4f416429c85b515f2a2a
oai_identifier_str oai:scielo:S0101-20612022000100557
network_acronym_str SBCTA-1
network_name_str Food Science and Technology (Campinas)
repository_id_str
spelling Comparison of CT and MRI in imaging diagnosis of aortic dissectionaortic dissectionCTMRIdiagnosis valueimagingAbstract Aortic dissection(AD) is a life-threatening disease due to a tear in the intimal layer of the aorta within the aortic wall. To compare diagnostic value and imaging of AD between computed tomography(CT) and magnetic resonance imaging (MRI). 120 AD patients diagnosed were examined with 64-slice CT and 1.5 MRI, the imaging data of true and false lumen, intimal flap, intimal tear, mural thrombus and aortic calcification were compared. The intimal flap rate of CT and MRI was 81.7% and 100%, respectively; The intimal tear rate of CT and MRI was 68.3% and 83.3%, respectively; The rate of mural thrombus in CT and MRI was 26.7% and 54.2%, respectively; The rate of aortic calcification in CT and MRI was 62.5% and 18.3%, respectively; The number of patients with intimal tear lower than 1mm in CT and MRI was 5 and 0, respectively. Both CT and MRI can show the true and false lumen well, but the detection rate of intimal flap, intimal tear and mural thrombosis in MRI is significantly higher than that in CT, and the detection rate of aortic calcification and intimal tear<1mm in CT is higher than that in MRI.Sociedade Brasileira de Ciência e Tecnologia de Alimentos2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612022000100557Food Science and Technology v.42 2022reponame:Food Science and Technology (Campinas)instname:Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)instacron:SBCTA10.1590/fst.23621info:eu-repo/semantics/openAccessWANG,JianingXIE,JunminMENG,XiaominGONG,Xuepengeng2022-02-22T00:00:00Zoai:scielo:S0101-20612022000100557Revistahttp://www.scielo.br/ctaONGhttps://old.scielo.br/oai/scielo-oai.php||revista@sbcta.org.br1678-457X0101-2061opendoar:2022-02-22T00:00Food Science and Technology (Campinas) - Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)false
dc.title.none.fl_str_mv Comparison of CT and MRI in imaging diagnosis of aortic dissection
title Comparison of CT and MRI in imaging diagnosis of aortic dissection
spellingShingle Comparison of CT and MRI in imaging diagnosis of aortic dissection
WANG,Jianing
aortic dissection
CT
MRI
diagnosis value
imaging
title_short Comparison of CT and MRI in imaging diagnosis of aortic dissection
title_full Comparison of CT and MRI in imaging diagnosis of aortic dissection
title_fullStr Comparison of CT and MRI in imaging diagnosis of aortic dissection
title_full_unstemmed Comparison of CT and MRI in imaging diagnosis of aortic dissection
title_sort Comparison of CT and MRI in imaging diagnosis of aortic dissection
author WANG,Jianing
author_facet WANG,Jianing
XIE,Junmin
MENG,Xiaomin
GONG,Xuepeng
author_role author
author2 XIE,Junmin
MENG,Xiaomin
GONG,Xuepeng
author2_role author
author
author
dc.contributor.author.fl_str_mv WANG,Jianing
XIE,Junmin
MENG,Xiaomin
GONG,Xuepeng
dc.subject.por.fl_str_mv aortic dissection
CT
MRI
diagnosis value
imaging
topic aortic dissection
CT
MRI
diagnosis value
imaging
description Abstract Aortic dissection(AD) is a life-threatening disease due to a tear in the intimal layer of the aorta within the aortic wall. To compare diagnostic value and imaging of AD between computed tomography(CT) and magnetic resonance imaging (MRI). 120 AD patients diagnosed were examined with 64-slice CT and 1.5 MRI, the imaging data of true and false lumen, intimal flap, intimal tear, mural thrombus and aortic calcification were compared. The intimal flap rate of CT and MRI was 81.7% and 100%, respectively; The intimal tear rate of CT and MRI was 68.3% and 83.3%, respectively; The rate of mural thrombus in CT and MRI was 26.7% and 54.2%, respectively; The rate of aortic calcification in CT and MRI was 62.5% and 18.3%, respectively; The number of patients with intimal tear lower than 1mm in CT and MRI was 5 and 0, respectively. Both CT and MRI can show the true and false lumen well, but the detection rate of intimal flap, intimal tear and mural thrombosis in MRI is significantly higher than that in CT, and the detection rate of aortic calcification and intimal tear<1mm in CT is higher than that in MRI.
publishDate 2022
dc.date.none.fl_str_mv 2022-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612022000100557
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612022000100557
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/fst.23621
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Ciência e Tecnologia de Alimentos
publisher.none.fl_str_mv Sociedade Brasileira de Ciência e Tecnologia de Alimentos
dc.source.none.fl_str_mv Food Science and Technology v.42 2022
reponame:Food Science and Technology (Campinas)
instname:Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)
instacron:SBCTA
instname_str Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)
instacron_str SBCTA
institution SBCTA
reponame_str Food Science and Technology (Campinas)
collection Food Science and Technology (Campinas)
repository.name.fl_str_mv Food Science and Technology (Campinas) - Sociedade Brasileira de Ciência e Tecnologia de Alimentos (SBCTA)
repository.mail.fl_str_mv ||revista@sbcta.org.br
_version_ 1752126331995291648